12-21
12
Functions Common to All the Control Modes
(a)
V/f scalar
P0300
Motor Speed
P0301
DEAD TIME
Open
Time
DIx – Run/Stop
+24 V
(b)
VVW and Sensorless Vector
P0300
Open
DIx – Run/Stop
DC Current
Injection
Time
+24 V
P0301
Motor Speed
Figure 12.11 -
(a) and (b) - DC braking operation at the ramp disabling (via ramp disable)
presents the DC braking operation via general disabling. This condition does only
work in the V/f scalar mode.
P0300
Time
+24 V
Motor Speed
Dead
Time
Open
DIx - General
Enable
Figure 12.12 -
DC braking operation via general disabling – V/f mode
For the V/f scalar control mode there is a "dead time" (motor rotates free), before starting the DC braking. This time
is necessary to the demagnetization of the motor and it is proportional to its speed.
During the DC braking the inverter indicates the "DCbreak" status at the keypad (HMI) top left corner.