![WEG bacnet CFW701 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/weg/bacnet-cfw701/bacnet-cfw701_user-manual_950625031.webp)
26 | CFW701
Keypad (HMI) and Basic Programming
E
ng
lis
h
Inverter status:
LOC:
local reference.
REM:
remote reference.
:
motor rotation according to the arrows.
CONF:
configuration. It indicates that the inverter is in the Oriented Start-up routine or with
incompatible parameter programming. Refer section Incompatibility Between Parameters in
the programming manual of the CFW701.
SUB:
DC link undervoltage.
RUN:
inverter enabled and/or DC braking activated.
Monitoring Mode
It is the initial state of the keypad after power up and startup screen,
with the factory default values.
The Menu is not active in this mode.
Main display and secondary display show the values of the parameters
defined at P0205 and P0206.
From the monitoring mode, pressing the ENTER/MENU key will switch
to the programming mode.
Programming Mode
Level 1:
This is the first level of the programming mode. It is possible to chose
the parameter group by using the
and
keys.
The main display, secondary display and variable unit are not shown
at this level.
Press the ENTER/MENU key to go to the level 2 of programming mode
- parameters selection.
Press the BACK/ESC key to go back to the monitoring mode.
Level 2:
The parameter number is displayed on the main display and its value
on the secondary display.
Use the
and
keys to find the desired parameter.
Press the ENTER/MENU key to go to level 3 of the programming mode
– parameters value changing.
Press the BACK/ESC key to return to level 1 of the programming mode.
Level 3:
The parameter values is shown at the main display and the parameter
number at the secondary display.
Use the
and
keys to change the value of the selected parameter.
Press ENTER/MENU key to confirm the modification (save the new value)
or BACK/ESC key to cancel the modification (do not save the new value).
In both cases, the keypad returns to the level 2 of the programming mode.
Figure 4.3:
Keypad operation modes
The keypad can be installed or removed from the inverter with or without AC power applied
to the inverter.
Содержание bacnet CFW701
Страница 49: ......
Страница 50: ...Manual del Usuario Serie CFW701 Idioma Español Documento 10001393824 03 Modelos Tam A E Fecha 12 2017 ...
Страница 97: ......
Страница 98: ...Manual do Usuário Série CFW701 Idioma Português Documento 10001393824 03 Modelos Mec A E Data 12 2017 ...
Страница 191: ...186 CFW701 Appendix B Anexo B Appendix B Anexo B ...