To operate the light

Turn ON: 

(When the light is OFF) Press the Button and hold it down for 1 second, 

the display is bright fully and then enters the flashing mode with 100% brightness;

Turn OFF: 

(When the light is ON) Press the Button and hold it down for 2 seconds;

Mode switch

When the light is ON: Press and immediately release the Button. White light 

 Red light 

 Blue light 

 Green light 

 Red light + Blue light + Green light (Manual color 

adjustment mode) 

 Red light + Blue light + Green light (Automatic color adjustment 

mode) 

 white light;

Brightness adjustment

Rotate clo, rotate counterclockwise-,
White light: Totally 11 levels from 0 to 100, the second level is 10%;
Red light + Blue light + Green light (color adjustment mode)

Totally 60 levels from 1 to 60;

SOS flash and strobe:

(When the light is OFF) Press the Button and hold it down for more than 3 seconds, 
The SOS mode will be on, Press and immediately release the Button: SOS 

 Rapid S

trobe 

 SOS Press the Button and hold it down for more than 2 seconds, 

the light will be off;

Temperature protection function

When the lamp holder temperature reaches 60

 it enters the temperature protection 

function with 20% lightness and the display shows "HOT"; when the temperature is 
below 40

, it exits the temperature protection function and the lightness turns 

to normal status;

Strobe function

This function is intended to help photographers use low-brightness white light or 
colored light to provide a focus light source. When the camera shutter is pressed, 
the white light will strobe for 0.1 second. At the same time, the focus light goes out, 
which realizing the effect of taking photos. The focus light will be turned on again 
after the strobe light goes out for 1 second.
- When using this function, you need to use the optical fiber cable to connect the 
camera and the torch.

Operation method

1. Select the focus light source : Under the normal working condition, 
select the required light source and adjust the appropriate brightness to focus.
2. Strobe mode : When the light is on, press and hold the button for 1.5 seconds 
to enter the strobe mode, then the strobe sign and white light indicator light on 
the screen is flashing, and the default brightness value is the highest that show 
number 9 on the screen . 
3. Select the strobe levels : rotate the knob to adjust the white strobe brightness, 
turn counter-clockwise to decrease the levels; turn clockwise to increase the levels. 
(There are 9 levels)

Focus function

Under the flashing mode, adjust the flashing brightness to 0% through rotating the 
knob counter-clockwise . 
When the light sensor detects the strobe light, the torch will automatically turn off and 
light up again one second later

Warnings

 Do not open the tail cap when the torch is in the water

 Do not shine the light directly into your eyes or another person's eyes

 Do not touch the battery or the charger with wet hands

 Only use the manufacturer's battery and charger with this system

 If the torch will not be used for a long period of time the battery 

      should be removed. Failure to comply with these warnings may 

      result in damage to the video light and will nullify the warranty.

★ 

Don’t disassemble or repair the torch , battery and charger by yourself.

      Please contact the local distributor in case of failure.

When the power is low, the brightness is reduced to 10% with display of 10 minutes 

countdown. It turns off automatically after 10 minutes. The flashing function is 

available under this status.

Support WFA03 remote control. Connect the torch and WFA03 with optical fiber cable;

Operation: 

Press the left button to reduce brightness.

Press the right button to increase brightness.

Press the middle button to switch the mode.

Long press the middle button to enter the sleeping mode and Long press the middle 

button again to wake it up. 

Low power protection

Remote control function

Remote control :

WFA03 remote control and optical fiber cable are optional accessories.

General maintenance

1.Put the torch into freshwater soaking for half an hour after diving.

2.When the battery is not in use for a long time, it is best to save the power at 70%.

3.The battery need to be charged and released at most every 6 months.

4.Before using the torch , check the O-ring of the tail cap to see whether there is 

any damage , cracks ,clamping marks, dirt , sand and so on.

5.Keep the silicon oil on the whole O-ring at the light tail .

6.The O-Ring should be replaced on time when it is cracked or damaged.

Note: Don’t use the sharp tools to remove the O-Ring . 

Video light brightness levels / Remain burn time

 Strobe power level

Continues light modes

Strobe indicator

1.Connect the AC charge plug to the power socket, and the indicator of the 

charger will turn green.

2.Insert the DC charger plug into the battery charging hole, and the indicator 

of the charger will turn from green to red .

3.When the battery is fully charged, the indicator light on the charger will turn green.

4.Don’t use the other brand charger to charge in case of fire and explosion .

To Charge the battery

DC charger plug