M1200
–
User manual
–
English (EU)
–
01/03/2018 - ISSUE 2
23
10.
Shut-down procedure
Upon completion of work, or when taking a break, the unit
must be shut down correctly:
•
Press the red stop button pictured on Figure 17. All
lights will extinguish apart from the white
‘
power
’
light
and the red fault light. The red fault light will remain
on until the water temperature in the M1200 drops
to
a
safe
level
and
the
pump
stops.
•
Wait until the red fault light switches off
•
Turn the isolator switch to ‘A’.
•
Tur
n the generator key switch to ‘A’.
DO NOT USE THE EMERGENCY STOP TO STOP THE
MACHINE OTHER THAN IN AN EMERGENCY.
The emergency
stop should only be used in an ‘emergency’
for example:
•
Water temperature exceeds 120 degrees centigrade
•
Steam emits from the lance
•
A significant leak occurs
IF THE EMERGENCY STOP HAS BEEN USED THE M1200
SHOULD BE CHECKED BY A COMPETENT SERVICE
ENGINEER, AND ANY FAULTS RECTIFIED BEFORE THE
M1200 IS SWITCHED BACK ON AGAIN.
Figure 17
–
Stop button showing on the PLC