background image

10

S

ON/OFF

Switch -- Ensure switch func-

tions properly by moving the switch to

the

OFF

position. Make sure motor

stops; then restart motor and continue.

S

Inlet Cover -- Discontinue use of unit if

inlet cover fails to latch properly or if it is

damaged in any way.

AFTER EACH USE

INSPECT AND CLEAN UNIT & LABELS

Stop unit and unplug extension cord.

S

After each use, inspect complete unit

for loose or damaged parts. Clean the

unit using a damp cloth.

S

Wipe off unit with a clean dry cloth.

CLEAN COLLECTION BAG

IMPORTANT:

THE COLLECTION BAG

MUST BE PROPERLY EMPTIED.

D

You must properly empty and maintain

the collection bag to avoid deterioration

and obstruction of air flow.

D

Remove the collection bag from the unit

and empty after each use. Do not store

bag without emptying the bag of all con-

tents (grass, leaves, etc.).

D

Wash the bag once a year. Remove the

bag from the blower and turn the bag in-

side out. Wash the bag with a water

hose. Allow the bag to hang and dry

completely before you reuse the bag.

SERVICE

HOW TO REMOVE AN OBJECT

FROM THE AIR INTAKE

WARNING:

Stop the unit and dis-

connect from the power source before

opening the inlet cover. The motor must

be stopped and the impeller blades no

longer turning to avoid serious injury

from the rotating blades.

1. While holding the inlet cover open,

remove the vacuum tubes. The inlet

cover must be held open through all

remaining steps.

2. Carefully reach into the vacuum

opening and clear out the air intake

area. Clear all debris from impeller.

3. Inspect the impeller for cracks. If

cracked or damaged, do not use the

unit. Have parts replaced by your au-

thorized service dealer. Do not at-

tempt to replace them yourself.

STORAGE

WARNING:

Perform the following

steps after each use:

S

Stop unit and disconnect from the pow-

er source.

S

Allow motor to cool before storing or

transporting.

S

Store unit with all guards in place. Posi-

tion unit so that any sharp object cannot

accidentally cause injury.

S

Store unit unplugged, well out of the

reach of children.

SEASONAL STORAGE

Prepare unit for storage at the end of

the season or if it will not be used for

30 days or more.

If your blower is to be stored for a period

of time:

S

Stop unit and disconnect from the pow-

er source.

S

Clean the entire unit before lengthy stor-

age.

S

Open inlet cover and clean any dirt,

grass, or debris that has collected. In-

spect the blower and all tubes. Close

and make sure the cover is latched.

S

Clean air vents and air inlet of debris.

S

Store your unit and extension cord in a

well ventilated area and covered, if pos-

sible, to prevent dust and dirt accumula-

tion. Do not cover with plastic. Plastic

cannot breathe and may cause con-

densation and eventual rust or corro-

sion.

S

Check entire unit for loose screws. Re-

place any damaged, worn, or broken

parts.

Содержание 545117528

Страница 1: ...ssements et toutes les instructions de s curit Tout d faut de le faire pourrait entra ner des blessures graves Instruction Manual Manual de Instrucciones Manuel d Instructions ENGLISH ESPA OL FRAN AIS...

Страница 2: ...the body away from openings and moving parts Hair jewelry loose clothing or clothing with loosely hanging straps ties tas sels etc can be caught in moving parts ELECTRICAL SAFETY WARNING Avoid a dang...

Страница 3: ...ceptacles are available having built in GFCI protection and may be used for this measure of safety S Stop the motor immediately if you are ap proached DOUBLE INSULATION CONSTRUCTION This unit is doub...

Страница 4: ...spreading chemicals fer tilizers or any other substances which may contain toxic materials VACUUM SAFETY S Stop the motor and disconnect the pow er source before opening the air inlet door or attempti...

Страница 5: ...attempt to use the vari able speed control during vacuum use Remove the inlet restrictor An inlet restrictor is used when using your unit as a blower This restrictor is not used during vacuum use and...

Страница 6: ...THE COLLECTION BAG 1 Carefully loop the shoulder strap through the buckle as shown in the il lustration below First In Last In 2 Position the unit on your right hand side blower outlet and bag pointi...

Страница 7: ...from the power source to the unit Otherwise loss of power and overheating can oc cur causing damage to unit Refer to table for minimum wire gauge recom mendations The cord must be marked with the pro...

Страница 8: ...EASE BUTTON secures the blower tube or elbow tube to the blower unit during operation Also pressing the tube release button allows removal of the blower tube or elbow tube VARIABLE SPEED CONTROL The V...

Страница 9: ...WARNING Do not vacuum stones gravel metal broken glass etc to avoid severe damage to the im peller To avoid the possibility of electri cal shock do not attempt to vacuum wa ter or other liquids Use yo...

Страница 10: ...cover open remove the vacuum tubes The inlet cover must be held open through all remaining steps 2 Carefully reach into the vacuum opening and clear out the air intake area Clear all debris from impel...

Страница 11: ...mited warranty period return it com plete prepaid with proof of purchase to the dealer from whom it was purchased for repair or replacement at the option of WEED EATER This warranty is not transferabl...

Отзывы: