background image

5

ASSEMBLY

WARNING:

Stop the unit and

disconnect from the power source be-

fore opening the inlet cover or attempt-

ing to insert or remove the inlet restrictor,

blower tube, or vacuum tubes. The mo-

tor must be stopped and the impeller

blades no longer turning to avoid serious

injury from the rotating blades.

WARNING:

If received as-

sembled, ensure your unit is properly

assembled and all fasteners are secure.

S

A standard screwdriver is required for

assembly.

BLOWER ASSEMBLY
NOTE:

Assembly instructions for using

your unit as a vacuum follow this section.

Attaching the blower tube

If you have already assembled your unit

for use as a vacuum, refer to the section

HOW TO CONVERT UNIT FROM VACUUM

USE TO BLOWER USE.

To attach blower tube:

S

Align the grooves on the blower tube

with the grooves on the blower outlet.

S

Push the blower tube onto the blower

outlet until it snaps into place (tube is

secured by red tube release button).

S

To remove the blower tube, press the

tube release button while pulling on

tube.

Blower Tube

Blower outlet

Tube Release Button

VACUUM ASSEMBLY

NOTE:

Assembly instructions for using

your unit as a blower are explained in the

previous section.

If you have already assembled your unit

for use as a blower, remove the blower

tube.

Remove the inlet restrictor

An inlet restrictor is used when using your

unit as a blower. This restrictor is not used

during vacuum use and must be removed

during assembly for vacuum use.

NOTE:

Be sure to keep the inlet re-

strictor for using your unit as a blower.

S

Ensure unit is stopped and extension

cord is unplugged.

S

Open the inlet cover by inserting the

tip of a screwdriver into the latch area

on the blower unit. Gently tilt handle of

screwdriver toward the front of the unit

to release the latch while pulling up on

the vacuum inlet cover with your other

hand.

Vacuum Inlet Cover (closed)

Latch Area

Bottom view
of unit

Vacuum Inlet Cover (opened)

Latch Area

Impeller

S

Turn the inlet restrictor counterclock-

wise and remove it from the unit. Do not

close the inlet door. You will next attach

the vacuum tubes.

Inlet
Restrictor

Vacuum
Inlet Cover

Attaching the vacuum tubes

There are 2 vacuum tubes, an upper

tube and a lower tube. The upper tube

has a vacuum assist handle attached to

one end and is cut straight on both ends.

The upper tube attaches to the blower

unit. The lower tube has an angled end

that you point toward the ground during

vacuum use. The lower tube attaches to

the upper tube.

S

Ensure unit is stopped and extension

cord is unplugged.

S

While holding inlet cover open, place

the hooks of the vacuum assist handle

on the retaining posts of the unit.

Upper Vacuum Tube

Vacuum Assist Handle

Hook

Содержание 530088049

Страница 1: ...it Tout d faut de le faire pourrait entra ner des blessures graves Instruction Manual Manual de Instrucciones Manuel d Instructions ENGLISH ESPA OL FRAN AIS 530088049 4 26 02 Please do not return unit...

Страница 2: ...use in rain in damp or wet locations or around swimming pools hot tubs etc Do not expose to snow rain or water to avoid the possibility of electrical shock Do not handle extension cord plug or unit wi...

Страница 3: ...pliance Failure to have the unit repaired by Sears service personnel can cause the double insulation construction to be come ineffective and result in serious in jury UNIT MAINTENANCE SAFETY S Turn of...

Страница 4: ...motor must be stopped and the impeller blades no longer turning to avoid serious injury from the rotating blades S Hard objects can be thrown through the collection bag or the housing and be come dang...

Страница 5: ...e the blower tube Remove the inlet restrictor An inlet restrictor is used when using your unit as a blower This restrictor is not used during vacuum use and must be removed during assembly for vacuum...

Страница 6: ...THE COLLECTION BAG S Carefully loop the shoulder strap through the buckle as shown in the il lustration below First In Last In S Position the unit on your right hand side blower outlet and bag pointin...

Страница 7: ...The cord mustbe markedwith the suffix W A in Canada W D Heavy enough to carry full current from the power source to the unit Otherwise loss of power and overheating can oc cur causing damage to unit...

Страница 8: ...turning then remove the vacuum tubes Carefully reach into the vacuum opening and clear out the clogged debris MAINTENANCE WARNING Disconnect power source before performing mainte nance GENERAL RECOMM...

Страница 9: ...or a period of time S Stop unit and disconnect from the pow er source S Clean the entire unit before lengthy stor age S Open inlet cover and clean any dirt grass or debris that has collected In spect...

Страница 10: ...LUX HOME PRODUCTS INC for this tool Addi tionally this warranty does not cover parts that will wear and require replace ment with reasonable use during the warranty period This warranty does not cover...

Отзывы: