WEDA PUMP RL 8010 Скачать руководство пользователя страница 4

 

4

GENERAL 

 

The RL submersible drainage pumps are designed for pumping lightly contaminated water . 
 
 

DESIGN

 

 

The heavy duty light weight

 

aluminium construction includes a cooling jacket ensuring adequate motor cooling at all 

times .  
The pumps are in 'plug and pumping design' , with built-in full overheat motor protection .  
The versions with level float  switch allow automatic operation .

 

The unique cartridge type seal package can be easily replaced on site with only minimum downtime

 . 

For demanding applications as in construction works and mining , the impellers are made for wear resistant Hi-Chrome 
iron and all other components are rubber lined . 
The impeller clearance is easily adjustable to compensate for wear .

 

 
 

TECHNICAL DATA

 

 

 RL8010 

 

Pump :

 

Discharge mm - (in) 

 

255 - (10") 

 

Suitable for media with pH 

5 - 8 

Maximum water temperature 

40°C 

Maximum submersible depth    m - (ft)  

20 - (67) 

Maximum solids size    mm - (in) 

Ø12 - (0.50) 

Weight (excluding cable )    kg - (lb) 

550 - (1222) 

Strainer  

Holes Ø12 - (0.50) 

Speed rpm  50Hz (60Hz) 

1450 - (1740) 

Stator insulation class 

F (155°C) 

 

 

 
 
 

Voltages  V 

Phases 

Frequency  Hz

Rated current  A 

 

Rated electrical 

power (kW) 

 

380 3 50  110 

63 

660 3 50 

 

 

440 3 60  110 

63 

 

Other voltages upon request 

 

IMPORTANT 

The above information is a general description only, is not guaranteed and contains no warranties of any kind

 

 
 
 
 

Power cables 50 / 60Hz   

 

 

 

 
 

2 x 20 meters 4x25 mm

2  

 

                                                              

 

 

All cables polychloroprene type HO7RN-F . 
 

 
 

Содержание RL 8010

Страница 1: ...INSTRUCTIONS SPAREPARTS CATALOGUE R RL L 8 80 01 10 0 RL8010 IS 10594 ENG GSNL...

Страница 2: ...e of the machine is restricted to the applications specified in the product literature Always change damaged parts immediately Change wear parts in due time SAFETY EQUIPMENT WARNING The admissible sou...

Страница 3: ...tain situations Keep away from all hot or spark generating objects do not smoke when handling fuel Wait until the machine has cooled before filling the tank Avoid spilling petrol or diesel on the grou...

Страница 4: ...Hi Chrome iron and all other components are rubber lined The impeller clearance is easily adjustable to compensate for wear TECHNICAL DATA RL8010 Pump Discharge mm in 255 10 Suitable for media with p...

Страница 5: ...5 Hydraulic characteristics 50Hz 60Hz Dimensions Dimensions in mm Dimensions in inch 600 23 6 1435 56 5 medium head...

Страница 6: ...explosive inflammable environment or used to pump inflammable liquids Route the cables so that connectors do not lie in the water Consider the risk of electrical accident Never lift the pump by its p...

Страница 7: ...o normal working temperature the motor protection switches on the contactor and the pump starts again TROUBLE SHOOTING Fault location Cause Action Pump will not start 1 Fuses blown 2 Broken cable 3 Po...

Страница 8: ...mpeller nut have to be tight to 400Nm These nuts and the pump stud bolts have to be glued with Loctite N 242 PUMP UPPER PARTS Put the top bracket of the pump on a holder placed on the ground Fig 2 Not...

Страница 9: ...the casing cpl Fig 6 Set the bearing housing complete See page 19 on the rotor end Fig 7 and secure it with retaining ring P N W50553 Note dismantling of bearing housing cpl Fig 8 Slide the complete r...

Страница 10: ...ered with O rings assembled Put in place the seal unit cpl on the inner casing on the stud bolts according to Fig 9 Fig 9 WEAR PLATE Set in place the wear plate P N W492017 using a mallet The wear pla...

Страница 11: ...The gap between the impeller and the wear plate must be as small as possible It is settled with Trimming spacers P N W494044 On a new pump there is 5 washers in order to get the right gap When the pum...

Страница 12: ...casing the bolts P N W494054 using Loctite N 242 Arrange to have the outer casing holes in front of the seal unit plugs Then set in place the outer casing on the top bracket Fig 15 Note Fig 14 disasse...

Страница 13: ...13 DIFFUSOR Set in place the diffusor P N W491006 on the pump stud bolts and secure it with nuts P N W84215 x8 Fig16 Note Disassembly method Fig 17 and 18 Fig18...

Страница 14: ...tre and the impeller must be as small as possible Adjust this gap tanks to nuts P N W84215 Avoid to get any contact between the impeller and the diffusor centre Fig 20 As soon as the setting is made p...

Страница 15: ...TRAINER Put in place the strainer P N W491007 using nuts P N W54215 x4 Then return the pump Fig 22 and screw in place lifting eyes P N W494085 and the pump discharge See discharges available page 6 Fi...

Страница 16: ...e specifications without notice SERVICE AND GUANRANTEE WEDAPUMP COM is represented worldwide by a well established service organization Contact your local WEDAPUMP sales office if you require more inf...

Отзывы: