Wecon LX3V-ETH-BD Скачать руководство пользователя страница 2

LX3V-ETH-BD

1

FUZHOU FU CHANG WECON ELECTRONICS TECHNOLOGY CO., LTD.

1. The installation instructions

Before the installation make sure that the PLC host and the equipment connected to bd board have

been powered off. Please install the BD module in the corresponding position of the PLC, and lock the four
standard screws. In case of the dust interference, please cover BD right part by PLC’s cover.

Note:

1) Install the board firmly on the PLC. Poor contact may cause malfunction.
2) The suggested tightening torque is 0.3-0.6 N.m.

Warning:

1) Disconnect the power supply before installing/removing the board and wiring in case of electric

shock or product damage.

2) The After completing the installation and wiring, do not replace the PLC top cover before turning

on the power.

Supported version:

LX3VP

25103 , 16050;LX3VE

25201, 16050.

LX3VP

25105

16000 or higher version

LX3VE

25203, 16000 or higher version.

2. Key Features

1) Maximum number of connections 8, regardless of master and slave.
2) The current protocol only supports: MODBUS-TCP.

3. The shape and terminal description

1) The case of one BD board

2) The case of two BD board

Содержание LX3V-ETH-BD

Страница 1: ...X3V ETH BD User manual Website http www we con com cn en Technical Support liux we con com cn Skype fcwkkj or Jason chen842 Phone 86 591 87868869 QQ Group 465230233 Technical forum http wecon freeforu...

Страница 2: ...ause malfunction 2 The suggested tightening torque is 0 3 0 6 N m Warning 1 Disconnect the power supply before installing removing the board and wiring in case of electric shock or product damage 2 Th...

Страница 3: ...communication command low byte defined by MODBUS protocol 2 m is the starting address number of the slave D is the length of the data read or write the unit is word The specific setting is shown in th...

Страница 4: ...onnection 6 1105 Connection 7 1006 Connection 7 1106 Connection 8 1007 Connection 8 1107 If n1 is set as k1002 then RS2 is configured for Ethernet port 1 connection 3 When x1 is ON the data is shown a...

Страница 5: ...The RS instruction needs to be used for the corresponding connection 5 Ethernet parameter settings The parameters of LX3V ETH BD module are configured by the CPAVL instruction The specific address of...

Страница 6: ...IP section 3 R W S 27 IP section 4 R W S 28 Port Default is K502 R W S 29 Reserved R W S 30 Command send interval Default is 0 1 ms R W S 31 Reserved R W S 32 Disconnect time When plc serves as slave...

Страница 7: ...92 168 1 35 set as follows Word address Decimal Hexadecimal 1 The IP address of BD module 192 C0 2 168 A8 3 1 01 4 35 23 MAC display description 192 168 1 35 51 5b a8 59 55 68 dynamic 2 Number of conn...

Страница 8: ...t flag D 10 Reserved connection 2 Configuration D 11 Instruction execution D 12 Instruction execution state D 13 Communication error flag D 14 Reserved D 15 Reserved D 16 Reserved D 17 Reserved D 18 R...

Страница 9: ...rd model As the picture shown above the Ethernet BD model is HFF20 K 224 according to the position 6 Examples 6 1 MODBUS Master 1 Ethernet parameter setting Configure the IP address as 192 168 1 36 Co...

Страница 10: ...he slave is 192 168 1 11 Configure Port number as 502 Configure timeout as 100ms Station number 01 function code 10 write word The start address for writing is 1 The length of address is 1 Write the d...

Страница 11: ...2 Gateway is 192 168 24 1 Subnet mask is 255 255 255 0 The connection number is 5 The protocol of device1 is Modbus slave The protocol of device2 is Modbus slave The protocol of device3 is Modbus slav...

Страница 12: ...error 44 9 Send timeout 45 10 19 interaction error between host and bd board 46 47 Error code display description Table 7 2 Address Display value description D8063 Expansion port 1 Conn 1 10000 error...

Отзывы: