Table 2-1 

Address 

Description 

Address 

Description 

M8112 

The  flag  of  thermocouple 

type in CH1 
OFF: K type 

ON: 

type 

D8112 

CH1’s temperature at 0.1 

 

units 

M8113 

The  flag  of  thermocouple 

type in CH2 

OFF: K type 

D8113 

CH2’s temperature at 0.1 

 units 

M8114 

CH3:  Flag  of  the  input 

mode 

OFF: Current output mode 

ON: 

Disabled 

D8114 

Digital value of CH3 

M8115 

CH4: flag of the input mode 

OFF: Current output mode 

D8115 

Digital value of CH4 

 

3.

 

Dimension 

 

 

Figure 3-1 

 

 

 

 

LED lights indicating: 

 

POW LED: Constantly ON when PLC power ON; 

 

COM LED: Lit when communicating PLC, OFF when timeout; 

 

CH1 LED: LED for CH1, constantly ON when analog signal in range, lit when analog signal out of 

range (K type: -100~1200

, J type: -100~600

). M8112=OFF K type, M8112=ON J type. 

 

CH2 LED: LED for CH2, constantly ON when analog signal in range, lit when analog signal out of 
range (K type: -100~1200

, J type: -100~600

). M8112=OFF K type, M8112=ON J type. 

 

CH3 LED: LED for CH3, constantly ON when M8114 turns OFF, OFF when M8114 turns ON. 

Table 2-1 

IN-2TC part   

2-wire thermocouple 

IN-2DAI Part Input voltage 

ranges: 4~20mA 

L1+ 

CH1  thermocouple  signal 

input (+) 

Io3+  CH3 current output (+) 

L1- 

CH1  thermocouple  signal 

input (-) 

Io3-  CH3 current output (-) 

▪ 

Disconnect 

▪ 

Disconnect 

L2+ 

CH2  thermocouple  signal 

input (+) 

Io4+  CH4 current output (+) 

L2- 

CH2  thermocouple  signal 

input (-) 

Io4-  CH4 current output (-) 

 

Содержание LX3V-2TC2DAI-BD

Страница 1: ...LX3V 2TC2DAI BD User manual Website http www we con com cn en Technical Support support we con com cn Skype fcwkkj Phone 86 591 87868869 QQ 1043098682 Technical forum http wecon freeforums net...

Страница 2: ...it of the LX3V can only use one BD board Don t try to use two or more BD boards these BD boards will not work 5 When mounting module to PLC all the lights are blinking after power ON PLC it means this...

Страница 3: ...communicating PLC OFF when timeout CH1 LED LED for CH1 constantly ON when analog signal in range lit when analog signal out of range K type 100 1200 J type 100 600 M8112 OFF K type M8112 ON J type CH2...

Страница 4: ...0 70mA Powered by PLC host Temperature input TC Analog input signal Thermocouple K or J type 2 channels CH1 CH2 Range of rated temperature K 100 1200 J 100 600 Digital output K 1000 12000 J 1000 6000...

Страница 5: ...e cable shall be grounded But their grounding point can be the same with high voltage lines 3 Never connect cable with forbidden size 4 Fix the cable so that the stress does not act on the terminal bo...

Страница 6: ...e cable stripped jacket Then connect the cable AWG16 1 309 5 2 Input and output mode 1 Thermocouple input mode 2 Current Output Mode 6 Example The analog values of each channel are transfer to digital...

Страница 7: ...er counter 6 2 Application example Since the LX3V 2TC2DAI BD does not have offset and gain functions if it needs for the values out of the standard specifications Additional programming orders will be...

Страница 8: ...mula Fahrenheit Celsius 9 5 32 the unit is 0 1 2 Current output mode In current output mode it changes the digital value 0 2000 to analog value 4 20mA If the real digital range is 0 A A means any valu...

Отзывы: