1.   Turn OFF cold water supply to RO system.  Turn OFF tank’s ball-valve.  Lift up RO faucet lever 

      briefly to relief the built-up pressure inside the RO system. This will make opening the housings 

      easier.

2.   Open housing:  Have the RO standing upright. Slip the plastic wrench onto the #1 housing. 

      Looking down from a top view, you should open the housing turning clockwise. If necessary, 

      lay RO down on the floor to get a better leverage. If the housing is too tight, use a hammer 

      and tap on the wrench handle to help turn the wrench.

3.   Discard 3 used filters, wash housings with mild soap, rinse off.  Put 3 new filters into their 

      respective housings:  sediment filter in stage-1, carbon block filters in stages 2 & 3.

4.   Close up the housings. Make sure each housing has a black O-ring in the thread groves. Use 

      wrench to tighten each housing.

5.   Remember:  Turn ON the cold water supply and OPEN the tank valve after finished changing 

      filters! 

6.   

Check for leaks!

CHANGING THE PRE-FILTERS

1.   Shut off the feed water to the system by turning the saddle valve on the water supply adapter 
      clockwise until it stops.
2.   Close the storage tank ball valve by turning the handle perpendicular to the valve body.
3.   Open the drinking water faucet relive pressure.
4.   Allow 3-5 minutes for pressure in the system to drop.
5.   Disconnect the tubing from the membrane cap by pushing in and holding down the end 
      collar ring surrounding the quick connect elbow fitting while gently pulling back on the tubing.
6.   Remove the membrane.
7.   Discard the used membrane.
8.   Insert the new membrane making sure it is properly seated in housing clip.
9.   Reconnect the removed tubing by pushing it into the elbow fitting in the housing cap.
10. Gently pull back on the tubing to insure a leak free connection.

CHANGING THE MEMBRANE

CAUTION: 

ANY REPLACEMENT FILTERS OR MEMBRANE NOT RECOMMENDED BY THE 

FACTORY CAN CAUSE SEVERE DAMAGE TO THE SYSTEM AND VOIDS ALL WARRANTIES.

Turn on the feed water to the system by turning the saddle valve at the water supply adapter 

counter - clockwise.Turn the storage tank ball valve handle parallel to the valve body.

VGRO Owners Manual

© 2017 Water Engineering Corporation

Содержание VGRO Series

Страница 1: ...VGRO Series Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO Reverse Osmosis Drinking Water Filter System Manual www wecofilters com...

Страница 2: ...the water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after system System must be installed indoor It is recommended that installation of the water f...

Страница 3: ...ct Water Flow Restrictor Check Valve INLET 3nd Stage CARBON PRE FILTER Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage tank w...

Страница 4: ...Flow Restrictor Check Valve INLET INLET 3nd Stage CARBON PRE FILTER BRINE IN Water supply adapter valve Cold water shut off valve Auxiliary faucet Garbage disposal Carbon Filters Drain Saddle Storage...

Страница 5: ...l chips will stain Porcelain 4 NOTE The drinking water system must be connected to the COLD water supply only 1 Turn off the cold water supply to the sink faucet by locating the Round or oblong handle...

Страница 6: ...o sink with the stem going through the hole 2 Place metal washer and lock washer over threaded stem of faucet and tighten nut from under the counter surface to lock the faucet into place DO NOT OVER T...

Страница 7: ...ain pipe and tighten the two screws evenly Fig 7 NOTE The center hole on the sponge must be removed 4 Connect the Black tubing to the drain clamp Fig 7 CONNECTING THE SYSTEM Use the color coded tubing...

Страница 8: ...aminated water is being rejected by the reverse osmosis membrane 7 START UP PROCEDURE DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY THE SYSTEM DISCHARGE THE WATER FROM THE STORAGE TANK BY OPE...

Страница 9: ...tank Drain the storage tank by lifting the faucet handle into the parallel position with the spigot until water flow stops from the tank Return the faucet handle to the closed position and the tank w...

Страница 10: ...tank Drain the storage tank by lifting the faucet handle into the parallel position with the spigot until water flow stops from the tank Return the faucet handle to the closed position and the tank w...

Страница 11: ...off the feed water to the system by turning the saddle valve on the water supply adapter clockwise until it stops 2 Close the storage tank ball valve by turning the handle perpendicular to the valve...

Страница 12: ...w wecofilters com For questions and concerns please feel free to contact our support staff Phone 1 888 675 5187 Email sales wecofilters com Water Engineering Corporation 1037 Stanley Ave Long Beach CA...

Страница 13: ...12 This page is intentionally left blank VGRO Owners Manual 2017 Water Engineering Corporation...

Страница 14: ...WECO VGRO Series Reverse Osmosis Drinking Water Filter System Manual Water Engineering Corporation Long Beach CA U S A 1 888 675 5187 sales wecofilters com WECO www wecofilters com...

Отзывы: