5
Connection Details
Valve Connector Pin out (Plug viewed from top)
Pins
Potentiometer
4 - 20 mA
0.5 - 5 VDC
1 = +In
1 = +In
1 = +In
2 = Pot +
2 = N/C
2 = N/C
3 = 0 Vdc
3 = 0 Vdc/4-20mA -
3 = 0 Vdc
4 = Pot Wiper
4 = N/C
4 = 0.5 - 5Vdc IN
5 = Pot -
5 = 4-20mA +
5 = 0.5 - 5Vdc GND
N.B. N/C = Do not connect
Connecting cable (5m) with Potentiometer
TSK6638-05
Connecting cable (5m) (4-20mA and 0.5 - 5V versions)
TSK6635-05
Consult sales for other lengths
Power Requirements
11 - 28 VDC.
Current Consumption 1.5 Amp during move at maximum inlet flow and maximum pressure. Current when in standby
< 100mA. Place a 2A Fuse between the power source and the VFD120MD valve. The power source and the fuse are