WEBPORT WP21202 Скачать руководство пользователя страница 1

 

 

Installation Guide  

0100125-01 Rev. A 

 
 

 

 
 

WebPort 2001  
Remote Maintenance IP Router 

Catalog Numbers  WP21202 (PSTN Modem) 
 

WP21205 (GSM/GPRS Modem) 

 

 

Содержание WP21202

Страница 1: ...Installation Guide 0100125 01 Rev A WebPort 2001 Remote Maintenance IP Router Catalog Numbers WP21202 PSTN Modem WP21205 GSM GPRS Modem...

Страница 2: ...1 4 2 Programmable Industrial Router functions 2 1 5 Typical applications 2 1 6 Part Numbers and internal options 2 1 7 External accessories 3 2 Structure of the WebPort technical documentation 4 3 H...

Страница 3: ...the GSM GPRS antenna 11 5 3 2 SIM card installation 12 5 4 Resets 12 5 4 1 User Reset 12 5 4 2 Factory Reset 13 5 5 Configurable serial port 14 5 6 Digital input 15 5 7 Open collector digital output...

Страница 4: ...RAS Programmable Industrial Router PIR 9 2 Ethernet 23 9 2 1 Direct connection 24 9 2 2 Connection over hub router 25 9 3 RJ45 connector 26 9 4 Input Outputs 27 9 5 Serial Port 28 9 6 Unitelway Modbu...

Страница 5: ...P client SNMP Manager Mail Recipient and thus to reduce significantly your costs implementation and ownership 1 2 General specification of the hardware platform Processor ARM clocked 75Mhz 8Mb SDRAM 8...

Страница 6: ...ational maintenance Diagnosis and machinery status control Stock and vessel level monitoring Process and machinery activity logs Commissioning support Remote programming Interface for Application Serv...

Страница 7: ...form Type Description Part Number WebPort 2001 PSTN33 PSTN modem WP21202 WebPort 2001 GSM GPRS GSM GPRS modem WP21205 WebPort 2001 EXT external modem WP21206 Option isolated serial port WPxxxxx 1x Opt...

Страница 8: ...sories Hardware specifications conformity to standards Installation recommendations and pinout of the connectors Step by step tutorial to establish first communications and make the IP configuration E...

Страница 9: ...WebPort 2001 Installation Guide page 5 ver 2 02 3 Housing and markings 3 1 Housing Figure 1 Housing front view Figure 2 Housing bottom view...

Страница 10: ...sh memory This SN is also used in order to scan the network for WebPorts and to assign its IP address subnet mask and gateway For more details See Equipment information and versions on page 7 3 3 Appl...

Страница 11: ...and versions The WebPort hardware and software revisions can be checked via a web browser on the WebPort server see Communicating with the WebPort on page 18 Once logged onto the WebPort clicking on...

Страница 12: ...to put the device in place or remove it To put the unit in place insert the top slider into the upper part of the rail with the WebPort tilted around 20 Then draw the latch at the bottom downwards wit...

Страница 13: ...und 3 8 Specifications for external power supply selection The WebPort 2001 has to be supplied by an external voltage source ranging from 12 to 24 VDC The power supplied must be SELV compliant securit...

Страница 14: ...s 5 1 Ethernet Port Please refer to the appendix Direct connection on page 24 and Connection over hub router on page 25 for information on the different Ethernet connection modes straight and crossed...

Страница 15: ...d USA Certificate number AU7MD01BMC56 Pinout phone line connector See label and appendix PSTN phone line connector on page 31 Specification Value Bands Dual band EGSM900 1800 MHz GPRS Class Class 2 Ma...

Страница 16: ...5 4 1 User Reset This is the first and most usual reset level It consists in formatting only the user file part of the non volatile memory The Tag configuration and the customer web site are part of...

Страница 17: ...secs until the procedure is completed The procedure finishes with the result of the autotest on the USER LED If the autotest is completed successfully then the USER LED shows its normal pattern of 20...

Страница 18: ...that switch 3 4 need to have the same position both ON or both OFF When they are ON it connects the internal polarisation typ 680 Ohms and termination typ 120 Ohms resistors This configuration applie...

Страница 19: ...te is detected when the input level is above 10Vdc Warning the logic level is undefined when the input is ranging between 5 and 10VDC Specification Value Input voltage range 0 to 24 VDC Input voltage...

Страница 20: ...is in an open collector type with pre drive This means the relay power supply has to be supplied from an external source to the pre drive electronics The diagram below shows the external wiring needed...

Страница 21: ...WebPort 2001 Installation Guide page 17 ver 2 02 Figure 14 Figure 15 Relay connector s label...

Страница 22: ...ation System Setup Communication DialUp PPP 6 2 By phone line or GSM 6 2 1 Under Windows 98 NT and 2000 1 Open the root folder Dial up Networking 2 Click on the icon Make new connection 3 Give a name...

Страница 23: ...ory and also under Start and Connect to as well as on your desktop if you selected the relevant option Create icon on desktop 10 You can now make a connection either by using the currently open window...

Страница 24: ...ning normally you cannot communicate with a device for which you don t know the IP parameters Therefore there is a special tool called eWONCfg you can download from the eWON Internet site http www ewo...

Страница 25: ...cal support If you need technical support contact Spectrum Controls via email at customersupport spectrumcontrols com or call 425 746 9481 More information on WebPort is also available on the web at h...

Страница 26: ...Appendix Pinouts and connections 9 1 Power Supply Figure 17 WebPort Mating female connector included Manufacturer Phoenix Contact GmbH http www phoenixcontact com Part Number GMSTB 2 5 2 STF 7 62 Pin...

Страница 27: ...ssed These cables have 8 copper conductors and are known as UTP Class 5 with RJ45 terminations at both ends These cables are availbale as spare parts see External accessories on page 3 The type of cab...

Страница 28: ...distance you have to take care of the twisted pairs This means that along with the above cabling conventions the emission TX TX and reception RX RX signals have to be connected on the same twisted pa...

Страница 29: ...onnection over hub router If the WebPort is connected to a hub it has to be connected like any other device with a straight cable Again the wiring is as shown on the following picture and care should...

Страница 30: ...WebPort 2001 Installation Guide page 26 ver 2 02 9 3 RJ45 connector The RJ45 connector has got the following pins numbering as it can be seen on the following picture showing it from different angles...

Страница 31: ...www sauro net Part Number CTF050VT Pin REF Description 1 DO_GND Output digital signal 0V ground connected to the emitter of the transistor 2 DO_OC Output digital signal connected to the collector of t...

Страница 32: ...e 28 ver 2 02 9 5 Serial Port Mating female connector not included 9 5 1 Pinout serial port according to mode Type Female DB9 with 4 40 blocking screws Pin RS232 RS485 RS422 1 2 RXD RX 3 TXD A TX 4 5...

Страница 33: ...WebPort 2001 Installation Guide page 29 ver 2 02 9 5 2 Pinout serial port 2 Pin RS232 1 DCD 2 RXD 3 TXD 4 DTR 5 COM GND 6 DSR 7 RTS 8 CTS 9 RI...

Страница 34: ...y to connect Schneider PLCs It has a SUBD9 connector at the WebPort side and a MiniDIN connector at the PLC side D A is connected to B and D B is connected to A MiniDIN PIN Schneider Signal Name WebPo...

Страница 35: ...ebPort 2001 Installation Guide page 31 ver 2 02 9 7 PSTN phone line connector Mating male conector not included Pinout PSTN line Type RJ11 type 6P2C without shield Pin Description 1 2 3 TIP 4 RING 5 6...

Страница 36: ...ikely event that the module should need to be returned to Spectrum Controls please ensure that the unit is enclosed in approved ESD packaging such as static shielding metallized bag or black conductiv...

Страница 37: ...ed Specifications subject to change without notice All trademarks are the property of their respective owners Corporate Headquarters Spectrum Controls Inc P O Box 5533 Bellevue WA 98006 USA Fax 425 64...

Отзывы: