Safe handling tips for Liquid Propane Gas
Cylinders

Liquid Propane (LP) gas is a petroleum product as 
are gasoline and natural gas. LP gas is a gas at 
regular temperatures and pressures. Under 
moderate pressure, inside a cylinder, LP gas is a 
liquid. As the pressure is released, the liquid readily
vaporizes and becomes gas.

LP gas has an odor similar to natural gas. You 
should be aware of this odor.

LP gas is heavier than air. Leaking LP gas may 
collect in low areas and prevent dispersion.

To fill, take the LP cylinder to an RV center, or look 

up “gas-propane” in the phone book for other 
sources of LP gas.

WARNING: We recommend that your LP cylinder 

be filled at an authorized LP gas dealer, by a 
qualified attendant, who fills the tank by weight.
IMPROPER FILLING IS DANGEROUS.

WARNING: If you exchange your LP cylinder,

make sure you get a similar tank in return. Your 
LP cylinder is equipped with a quick closing 
coupling or type 1 valve and an OPD (Overfilling 
Prevention Device). Other LP cylinders may not 
be compatible with your grill connection.

Air must be removed from a new LP cylinder before
the initial filling. Your LP dealer is equipped to do 
this.

The LP cylinder must be installed, transported and 
stored in an upright position. LP cylinders should 
not be dropped or handled roughly.

Never store or transport the LP cylinder where 
temperatures can reach 125° F (too hot to hold by 
hand - for example: do not leave the LP cylinder in 
a car on a hot day).

Note - A refill will last about 20 hours of cooking time
at normal use. The fuel scale will indicate the propane
supply so you can refill before running out. You do not
have to run out before you refill.

Treat “empty” LP cylinders with the same care as 
when full. Even when the LP tank is empty of liquid 
there still may be gas pressure in the cylinder.

Always close the cylinder valve before 
disconnecting.

CAUTION: When transporting the LP cylinder 

make sure the plastic dust cover is in place over
the valve. This will keep dust and dirt from the 
threaded portion of the valve.

Do not use a damaged LP cylinder. Dented or rusty
LP cylinders or LP cylinders with a damaged valve 
may be hazardous and should be replaced with a 
new one immediately.

Liquid Propane (LP) Cylinder(s)

The joint where the hose connects to the LP 

cylinder must be leak tested each time the LP 
cylinder is reconnected. For example, test each time
the LP cylinder is refilled.

Be sure the regulator is mounted with the small 
vent hole pointed downward so that it will not collect
water. This vent should be free of dirt, grease, 
bugs etc.

The connections supplied with your  Vieluxe

®

gas 

grill have been designed and tested to meet 
government, Canadian Standards Association, and 
Underwriters Laboratories requirements.

If you have questions about spare LP cylinders
contact the Vieluxe

®

Customer Service at 

1-866-VIELUXE.

All LP tank supply systems must include a collar to 
protect the cylinder valve.

The LP cylinder must be a 20-lb. size (18 1/4 inches
high, 12 1/4 inches in diameter).

The cylinder should be constructed and marked in 
accordance with the Specifications for LP - Gas 
Cylinders of the U.S. Department of Transportation 
(D.O.T.) or the National Standard of Canada, 
CAN/CSA-B339, Cylinders, Spheres and Tubes or 
Transportation of Dangerous Goods; and
Commission, as applicable.

DOT 4BA240

 

00/01

(1)

(2)

Содержание Vieluxe 36251

Страница 1: ...ler assembled WARNING Do not try to light this appliance without reading Lighting instructions section of this manual THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY DANGER If you smell gas 1 Shut...

Страница 2: ...pen burner station or place hands or fingers on the front edge of the burner station Should a grease fire occur turn off all burners and close lid until fire is out Do not enlarge valve orifices or bu...

Страница 3: ...11 TO EXTINGUISH 11 MANUALLY LIGHTING THE LEFT RIGHT BURNERS 12 TO EXTINGUISH 12 GENERAL MAINTENANCE 13 CHECK FOR GAS LEAKS 13 REMOVE CONTROL PANEL 13 REINSTALL CONTROL PANEL 15 REINSTALL BURNER CONTR...

Страница 4: ...se misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to perform normal and routine maintenance including but not limited to damage caused b...

Страница 5: ...NING Never store an outdoor cooking gas appliance indoors unless the LP cylinder is disconnected and removed from the outdoor cooking gas appliance WARNING LP Cylinders must be stored outdoors out of...

Страница 6: ...ers see Section Operating Important LP Cylinder Information Failure to follow these DANGER statements exactly may result in a fire causing death or serious injury DANGER NEVER store a spare LP Cylinde...

Страница 7: ...the valve 4 Screw the regulator coupling onto the tank valve clockwise or to the right Hand tighten only Note This is a new type of connection It tightens clockwise and will not allow gas to flow unl...

Страница 8: ...as grill Shipping and handling may have loosened or damaged a gas fitting WARNING Perform these leak checks even if your grill was professionally installed You will need a soap and water solution and...

Страница 9: ...l take LP cylinder to a Gas Propane dealer WARNING We recommend that your LP cylinder be filled at an authorized LP gas dealer by a qualified attendant who fills the cylinder by weight IMPROPER FILLIN...

Страница 10: ...propane supply so you can refill before running out You do not have to run out before you refill Treat empty LP cylinders with the same care as when full Even when the LP tank is empty of liquid ther...

Страница 11: ...e OFF position gas will flow to the burners This condition can cause a fire or explosion resulting in serious bodily injury or death Make sure all burner control knobs are turned OFF Push control knob...

Страница 12: ...gas flow control feature is activated a small amount of gas is still flowing to the burners After turning OFF the cylinder knob wait at least 5 minutes for the gas to clear before attempting to light...

Страница 13: ...from the burner station WARNING The gas connections of your Vieluxe burner station have been factory tested We do however recommend that you leak check all gas connections before operating your Vielu...

Страница 14: ...all connections should be rinsed with water after checking for leaks WARNING Make sure all burner control knobs are in the OFF position Check for leaks by wetting the connections with the soap and wa...

Страница 15: ...trol knobs 1 in through the bezels onto the valve stems Push the igniter 4 through the control panel so that the threads appear replace the igniter nut 3 and the igniter button 2 You will need 2 contr...

Страница 16: ...e Check that all burner components are in place AlsoCheck that the orifice is not obstructed 2 3 4 1 Replace igniter battery Parts required 1 AA alkaline battery Unscrew igniter button from front of c...

Страница 17: ...burner light with a match Is burner ring properly installed Cure Turn supply on Straighten hose To resest the exess flow safety device turn all burner control knobs and the cylinder valve OFF Disconne...

Страница 18: ...er cap burner ring burner head and burner base 2004 Weber Stephen Product Co Vieluxe Flavorizer and Crossover are registered U S trademarks Gas Catcher is a trademark all of Weber Stephen Products Co...