Weber Summit 475 NG Скачать руководство пользователя страница 1

SUMMIT 475 & 675

Natural Gas Barbecues

Summit 475 NG

Summit 675 NG

THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

G

ENERAL

I

NFORMATION

BUILT-IN CONSTRUCTION GENERAL INFORMATION

WARNING

A Weber-Stephen Products Co. insulated sleeve must be used for any built-in  installation.

CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES

Warning: Clearance from the outside walls of the sides and
back of the insulated sleeve must be a minimum of 24
inches from a combustible surface. Measure from the
outside wall of the insulated surface to the combustible
surface. Figure 2. Refer to “Install Gas Supply” on page 2
before starting installation.

Figure 2

Figure 1

CLEARANCE FROM NON-COMBUSTIBLE SURFACES OR
STRUCTURES

Warning: Clearance from the outside walls of the sides and
back of the insulated sleeve must be a minimum of 6 inches
from a non-combustible surface. Measure from the outside
wall of the insulated surface to the non-combustible
surface. Figure 1. Refer to “Install Gas Supply” on page 2
before starting installation.

COMBUSTIBLE SURFACE

24 inches

24 inches

24 inches

NON- COMBUSTIBLE SURFACE

6 inches

6 inches

6 inches

WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.

WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.

Countertop

Countertop

Insulated sleeve

Insulated sleeve

LOCATING YOUR  BARBECUE

When determining a suitable location for your barbecue installation, give attention to concerns such as exposure to wind, proximity to
traffic paths, and keeping any gas supply lines as short as possible. Never locate the Weber Gas Barbecue in a garage, breezeway,
shed, under an unprotected overhang, or other enclosed area. Locate the barbecue and structure so there is enough room to safely
evacuate the area in case of a fire.

THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

98251 3/99

Содержание Summit 475 NG

Страница 1: ...combustible surface Measure from the outside wall of the insulated surface to the non combustible surface Figure 1 Refer to Install Gas Supply on page 2 before starting installation COMBUSTIBLE SURFA...

Страница 2: ...e located in a low visibility area and should be protected by screening material to prevent rodents and insects from entering the structure Air holes will also help dry moisture Before installing the...

Страница 3: ...upporting structure We recommend a minimum of 100 square inches of venting per side Vents should be on two sides of the structure Figures 5 and 6 are references only Location of the vents should be fr...

Страница 4: ...E BY A LICENSED PROFESSIONAL General Specifications for Piping Note Contact your local municipality for building codes regulating outdoor gas barbecue installations In absence of Local Codes you must...

Страница 5: ...face Measure from the outside wall of the sleeve to the non combustible surface Figure 1 Refer to Install Gas Supply on page 2 before starting installation COMBUSTIBLE SURFACE 24 inches 24 inches 24 i...

Страница 6: ...g to use a rotisserie with the cooking module make sure you space the side burner far enough away to facilitate its use Before installing the sleeve lay a bead of silicon sealant around the top perime...

Страница 7: ...as short as possible Never locate the Weber Gas Side Burner in a garage breezeway shed under an unprotected overhang or other enclosed area Locate the side burner and structure so there is enough room...

Страница 8: ...her material which may corrode the piping must be protected against corrosion in an approved manner Underground piping must have a minimum of 18 cover Test connections All connections and joints must...