22
GAS SUPPLY
BUILT-IN GAS LINE LOCATIONS
1
2
3
a
c
2
3
1
b
460
660
TOLERANCES
1
16 1/2" (419.1 mm)
16 1/2" (419.1 mm)
±1/8" (3.2 mm)
2
11 1/8" (282.6 mm)
11 1/8" (282.6 mm)
±1/8" (3.2 mm)
3
2 1/2" (63.5 mm)
2 1/2" (63.5 mm)
±1/8" (3.2 mm)
a
Plan view right
b
Side view
c
Gas inlet
BUILT-IN GAS LINE LOCATIONS
Note: Leave an access in the “island” structure for gas supply and regulator service that
is not inside the grill structure.
Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to
avoid possible damage to gas supply lines. Exercise caution when pulling gas lines
through built-in structure.
X
TYPICAL NATURAL GAS SUPPLY INSTALLATION
We recommend that this installation be done by a LICENSED professional.
General Specifications For Piping
Note - Contact your local municipality for building codes regulating outdoor gas grill
installations. In absence of Local Codes, you must conform to the latest edition AS560/
AG-601.
r 5IJTHSJMMJTEFTJHOFEUPPQFSBUFBU,QB
r "NBOVBMTIVUPGGWBMWFNVTUCFJOTUBMMFEPVUEPPSTBOECFBDDFTTJCMF"OBEEJUJPOBM
manual shut-off valve indoors should be installed in the branch fuel line in an
accessible location near the supply line.
r 5PTFUOPNJOBMUFTUQPJOUQSFTTVSFUP,QBUVSO.BJOCVSOFSTPO)JHIPOMZ"EKVTU
UIFSFHVMBUPSPVUMFUQSFTTVSFUP,QB
r 5IFIPTF TUPCFVTFEBSFNNBOENNTUBJOMFTTTUFFMCSBJEFENN*%
with bayonet fittings, AGA # 4007.
r 6TFPOMZBL1BOBUVSBMHBTSFHVMBUPS#FDLMFZ"("*G#FDLMFZJTOPU
BWBJMBCMFVTF#SPNJDNPEFM#.8'*"("BQQSPWBM
!
CAUTION: If young children are in the area, a locking valve
should be considered.
r 1JQFDPNQPVOETIPVMECFVTFEXIJDIJTSFTJTUBOUUPUIFBDUJPOPGMJRVJEQSPQBOFHBT
when gas connections are made.
r 5IFHBTDPOOFDUJPOTNVTUCFGJSNMZBUUBDIFEUPBSJHJEQFSNBOFOUDPOTUSVDUJPO
.
Note: The information provided in this manual is general for typical installations. We
cannot cover all possible installation ideas. We recommend, prior to installation, that you
contact your municipality for local building codes and your local fire department for
installation verification.
X