OPERATING

 WARNING: Only use the Weber

®

 Tank Enclosure 

Kit outdoors in a well-ventilated area. Do not use in 
a garage, building, breezeway or any other enclosed 
area.

 WARNING: Your Weber

®

 Tank Enclosure Kit shall 

not be used under an unprotected combustible roof or 
overhang.

 WARNING: Your Weber

®

 Tank Enclosure Kit is not 

intended to be installed in or on recreational vehicles 
and/or boats.

 WARNING: Keep any electrical supply cord and the 

fuel supply hose away from any heated surface.

 WARNING: Never store an extra (spare) LP cylinder 

under or near the Weber

®

 gas barbecue.

 WARNING: Keep the ventilation openings of the 

cylinder enclosure free and clear of debris.

 WARNING: Turn off the gas at the LP gas supply 

cylinder when the outdoor cooking gas appliance is 
not in use.

 WARNING: Never store an outdoor cooking 

gas appliance indoors unless the LP cylinder is 
disconnected and removed from the outdoor cooking 
gas appliance.

 WARNING: LP Cylinders must be stored outdoors 

out of the reach of children and must not be stored in a 
building, garage, or any other enclosed area.

 WARNING: The LP pressure regulator and hose 

assembly supplied with the Weber

®

 Tank Enclosure Kit 

must be used. Replacement LP pressure regulators 
and hoses must be obtained from Weber-Stephen 
Product Co.

WARRANTY

WARRANTY

Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL 
PURCHASER of this Weber

®

 gas grill that it will be free of defects in 

material and workmanship from the date of purchase as follows:

All Parts,  

5 years

when assembled and operated in accordance with the printed instructions 
accompanying it.
Weber may require reasonable proof of your date of purchase. THEREFORE, 
YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE.
This Limited Warranty shall be limited to the repair or replacement of parts that 
prove defective under normal use and service and which on examination shall 
indicate, to Weber’s satisfaction, they are defective. Before returning any parts, 
contact the Customer service representative in your region using the contact 
information sheet provided with your manual. If Weber

®

 confi rms the defect 

and approves the claim, Weber

®

 will elect to replace such parts without charge. 

If you are required to return defective parts, transportation charges must be 
prepaid. Weber

®

 will return parts to the purchaser, freight or postage prepaid.

This Limited Warranty does not cover any failures or operating diffi culties due 
to accident, abuse, misuse, alteration, misapplication, vandalism, improper 
installation or improper maintenance or service, or failure to perform normal 
and routine maintenance, including but not limited to damage caused by insects 
within the burner tubes, as set out in this owner’s manual.
Deterioration or damage due to severe weather conditions such as hail, 
hurricanes, earthquakes or tornadoes, discoloration due to exposure to 
chemicals either directly or in the atmosphere, is not covered by this Limited 
Warranty.

There are no other express warrants except as set forth herein and any 
applicable implied warranties of merchantability and fi tness are limited in 
duration to the period of coverage of this express written Limited Warranty. 
Some regions do not allow limitation on how long an implied warranty lasts, so 
this limitation may not apply to you.
Weber

®

 is not liable for any special, indirect or consequential damages. Some 

regions do not allow the exclusion or limitation of incidental or consequential 
damages, so this limitation or exclusion may not apply to you.
Weber

®

 does not authorize any person or company to assume for it any other 

obligation or liability in connection with the sale, installation, use, removal, 
return, or replacement of its equipment; and no such representations are 
binding on Weber

®

.

This Warranty applies only to products sold at retail.

WEBER-STEPHEN PRODUCTS CO.
Customer Service Center
1890 Roselle Road, Suite 308
Schaumburg, IL 60195
USA

www.weber.com

®

Содержание SUMMIT 42390

Страница 1: ...ich can cause serious bodily injury or death or damage to property WARNING 1 Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance 2 An LP cy...

Страница 2: ...pane gas is not natural gas The conversion or attempted use of natural gas in a liquid propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty Do not attempt...

Страница 3: ...xamination shall indicate to Weber s satisfaction they are defective Before returning any parts contact the Customer service representative in your region using the contact information sheet provided...

Страница 4: ...cylinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow area of the island Ventilation openings in the sidewalls of the enclosure should only communicate with the...

Страница 5: ...he structure island counter tops and adjacent work areas for the LP Tank Enclosure must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombu...

Страница 6: ...8 4 1 2 4 2 2 PARTS LIST Hose and regulator 1 Tank stand 1 Tank stand base 1 Tank Scale 1 1 4 20 nut 6 Nylon washer 12 1 4 20 x 1 2 bolt 6 Cylinder glide 2 1 2 Flare Gasket 2 3 8 Flare Gasket 2 ASSEMB...

Страница 7: ...re before use MOUNTING HARDWARE NOT INCLUDED MOUNTING THE LP HOSE AND REGULATOR Securley mount the hose and regulator bracket to the top of the built in tank enclosure using non corrosive hardware MOU...

Страница 8: ...de View back of box top of box 1 2 Flared Gasket 3 Use the 1 2 inch flared gasket to ensure proper seal NOTE Only use the 3 8 inch flared gasket if you are installing the optional side burner 4 Connec...

Страница 9: ...water solution and a rag or brush to apply it 1 Turn the LP cylinder so the opening of the valve is either to the front side or rear of the Weber gas barbecue Lift and hook the cylinder onto the fuel...

Страница 10: ...eck for gas leaks every time you disconnect and reconnect a gas fitting Note All factory made connections have been thoroughly checked for gas leaks The burners have been flame tested As a safety prec...

Страница 11: ...er make sure you get a similar tank in return Your LP cylinder is equipped with a quick closing coupling or type 1 valve and an OPD Overfilling Prevention Device Other LP cylinders may not be compatib...

Страница 12: ...PRODUCTS CO www weber com GAS INSTRUCTIONS If you have questions about spare LP cylinders contact Customer Service at 1 800 446 1071 All LP tank supply systems must include a collar to protect the cy...

Отзывы: