103666_EBH_Rev1.0_080215
MPE 750 Turbo Marine
Closed Loop
Installation Guide
Page 22
7
First engine run and brake in
Procedure:
Check at
fi
rst the connection to the drive train. Therefore disconnect the ignition coils to avoid a starting of the
engine. Crank the engine by using the starter, do not crank longer than 10 seconds and repeat as needed.
Check the drive train for abnormal behaviour (e.g. mechanical noise). Reconnect the ignition coils
After the engine installation is
fi
nished a
fi
rst run with the boat out of the water is recommended. Therefor use
the
fl
ush system to avoid any damage of the engine due to overheat. The use of the
fl
ush system is described
in section 4.2.
1)
Remove cable harness on the ignition coils (1).
2)
Loosen the cable harness on the cable holders (2).
3)
Remove the cable harness on the injection valves (3).
1
2
3
ATTENTION
Engine is delivered
fi
lled with engine oil by the factory