  Description: If the primary phone number contains digits, the WebbPhone dials this 

number when the call button is pushed. It will redial this number up to 3 times if it is 

not successful in establishing contact.

Note:  If  the  WebbPhone  is  connected  to  ringdown  equipment  (including  an  LS-250  Rescue 
Station set to either “Lobby” or “Split Ring” mode), an off-hook service provided by the telephone 
company, or to an auto-dialer, we do not recommend using an off-hook service from the telephone 
company or a separate auto dialer. This makes troubleshooting very difficult if maintenance is 
ever necessary. From a safety perspective, it may prevent monitoring and rescue personnel from 
calling back to the passenger.

Note: Some switchboards require an 8 or a 9 followed by a pause in order to access an outside 
line. In this situation, you would enter an 8# or 9# followed by the telephone number to be dialed. 
If a longer pause is needed, the # key may be pressed more than one time. Each # entry creates 
a 2 second pause. 

4.5.2  SECONDARY PHONE NUMBER (Analog) 

  Command #: 2

  Voice Prompt: “SECONDARY PHONE NUMBER”

  Value Range: 25-digit capacity (any digit or “#” to add a 2 sec pause #)

  Factory Setting: Blank

  Description:  If  a  secondary  phone  number  is  entered  and  the  WebbPhone  is 

unsuccessful in reaching the primary phone number, the unit will switch over and dial 

the secondary phone number. 

Note: If no contact is made with the secondary number, the WebbPhone will begin the cycle again 
by dialing the primary number. After 3 unsuccessful cycles, the unit will shut off. 

4.5.3  AUTO ANSWER 

  Command #: 3 

  Voice Prompt: “AUTO ANSWER” 

  Value Range: 0 = OFF, 1 = ON with ‘connected’ announcement, 2 = 

  ON with no announcement. 

  Factory Setting: 1 

  Description: The auto answer setting determines whether or not the WebbPhone may 

be called  by an outside party and, if so, whether  or not the  unit will ring when it is 

being called. 

Note: In setting = 1, the unit will beep and then automatically answer. Setting = 2 is often called 
“Silent Monitoring” because the unit will silently turn on and allow the calling party to listen to the 
activities in the elevator. Please note that two-way communication is still enabled, so the elevator 
can also hear the calling party. 

4.5.4  LOCATION ANNOUNCEMENT 

  Command #: 4

  Voice Prompt: “LOCATION ANNOUNCEMENT”

  Value Range: 15 second maximum

  Factory Setting: Blank

  Description: The location announcement is a recorded message that the monitoring 

station  may  play  prior  to  speaking  with  the  caller.  The  recording  would  normally 

include the building name, the address and the elevator number. Suggested recording 

format:  “This  is  Elevator  #2  of  the  Vancouver  Building  at  3215  Hemlock  Street  in 

Springfield, Michigan. Assistance is required.” Try to avoid as much background noise 

as  possible  when  doing  the  recording.  This  can  be  programmed  remotely  using  a 

cellphone or landline. 

 

Содержание MWP-302

Страница 1: ...MWP 302 USER MANUAL RAFAEL CONVERGENT ROBOTIC TECHNOLOGIES Company address...

Страница 2: ...HIGH RISE APPLICATION GREATER THAN 6 STOREYS 4 4 PROGRAMMING 5 4 1 GENERAL 5 4 2 THE KEYPAD 5 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD 7 4 4 REPLAY 8 4 5 PROGRAMMING ROUTINES 8 4 6 REMOTE PROGRAMMI...

Страница 3: ...will begin flashing to alert them that their call has been connected and they can be heard It is also possible to call into any WebbPhone Phones on the same telephone line need to be programmed with a...

Страница 4: ...fully programmed to specific site equipment and customer requirements NOTES A maximum of 6 WebbPhones may be connected to a single phone line A touch tone analog telephone line is required WebbPhones...

Страница 5: ...will request the other users to hang up their phone call 3 1 2 CALLING IN The calling party dials the telephone number associated with the telephone line connected to the WebbPhone If the line is not...

Страница 6: ...ming remotely The WebbPhone should have its transformer connected to a 120V 60 Hz AC power source in order to be programmed Its backup battery may also be used for programming if AC power is temporari...

Страница 7: ...mber 0 25 digits Blank 2 Secondary Phone Number 0 25 digits Blank 3 Auto Answer 0 Off 1 1 On w ring 2 On w no ring 4 Location Announcement 15 seconds max Blank 5 Access Code 5 digits 12345 6 Station N...

Страница 8: ...26 Reset IP 1 Reset N A Speaker Volume 1 Lowest 3 No need to press ENTER 6 Highest Mic Volume 1 Lowest 3 No need to press ENTER 6 Highest 4 3 PROGRAMMING USING THE WEBBPHONE KEYPAD The WebbPhone shou...

Страница 9: ...all of the dialing digits followed by the ENTER key The WebbPhone will audibly announce INPUT ACCEPTED YOU ENTERED followed by all of the digits entered The WebbPhone is back in main programming mode...

Страница 10: ...pause Factory Setting Blank Description If a secondary phone number is entered and the WebbPhone is unsuccessful in reaching the primary phone number the unit will switch over and dial the secondary...

Страница 11: ...hecked or reset on the WebbPhone 4 5 6 STATION NUMBER Analog only Command 6 Voice Prompt STATION NUMBER Value Range 1 80 Factory Setting 1 Description A unique number must be assigned to each WebbPhon...

Страница 12: ...Description This is the length of time that the WebbPhone will permit a caller to be put on hold before it hangs up and dials the next number in its sequence The timer is cancelled as soon as the oper...

Страница 13: ...diagnostics done in a voice format When Voice Alert is activated the elevator telephone will provide a voice announcement over its internal speaker if it detects loss of the phone line loss of AC pow...

Страница 14: ...e The battery is a rechargeable Li Ion battery and should have a full charge within 1 day of the WebbPhone being connected to AC power Even if the battery indicates a full charge it should be replaced...

Страница 15: ...ss Code EXIT 9 ENTER REPLAY Table 4 Remote Programming To program remotely 1 From any phone call the telephone number of the line connected to the WebbPhone Once you hear the voice prompt enter the se...

Страница 16: ...input 12V DC 1A output Maximum number of units 6 sharing the same phone line On hook Phone Line Voltage 24V 55V nominal 48V DC Off hook Phone Line Voltage 3V 10V nominal 6V DC On hook Power Required 0...

Страница 17: ...aker and Microphone holes align between the MWP 302 and the COP 8 WARRANTY AND RETURNS Webb Electronics Inc warrants parts and labor on all equipment of its own manufacture for a period of 24 months f...

Страница 18: ...o remove the equipment from the network until the problem is resolved This equipment cannot be used on public coin service provided by the telephone company Connection to party lines is subject to sta...