Liability claims: 

 

– Failure to observe the operating instructions and the infor-

mation contained in it will result in a disclaimer of liability by 

Webasto.  

The same applies if repairs are carried out incorrectly or with the 

use of parts other than genuine spare parts. This will result in 

the invalidation of the type approval for the heater and therefore 

of its general operating licence/EC type approval. 

 

– Liability claims can only be asserted for proven compliance with 

the maintenance and safety instructions by the applicant. 

Operating Heater

Before switching on the heater (with the ignition on), the vehicle heating system should be set 

to “warm” and the vehicle heating blower should be set to the slowest setting (lower power 

consumption). Depending on the type of vehicle, the air-conditioning system can perform these 

settings automatically or partly autonomously. Please ask your specialist dealer to explain the 

optimum settings.

For ADR hazardous material vehicles only: 

The Thermo Pro 90 HDD heater is switched on and off manually by means of a switch. 

Automatic controllers are prohibited. In vehicles of the type FL, the operation of these heaters 

is prohibited during loading and unloading and at the loading points. The generator signal and 

auxiliary drive signal are requested for this purpose. 
In vehicles of type FL, the heaters are automatically switched off and the maximum ADR after-

running time is 40 s in accordance with the legal specifications. 
An ADR afterrunning period takes place if:

 

– the generator signal (D+) is discontinued or

 

– the auxiliary drive signal (e.g. pumping device) is present.

After the end of the ADR afterrunning period, the control unit is in ADR locking mode. 
The heater can be restarted by switching it off and on again using the “ON/OFF” switch. This 

will not work while the pumping device belonging to the vehicle is in operation. The ADR 

lock will not be cancelled if the “ON/OFF” switch is activated and the operating voltage Ub is 

removed and reapplied. 
The disconnector (emergency off switch) may only be actuated in the event of danger since the 

heater will be switched off without afterrunning period (possible overheating). 

Heater operation: 

If the heater is switched on with a cold engine, the heater starts up in a low load range and 

then increases the power. Depending on temperature, this process can take approx. 2 minutes. 

The coolant temperature is controlled automatically throughout operation. The heater can also 

be switched on while travelling. The vehicle blower is only switched on when the coolant tem-

perature is at around 30°C, avoiding unnecessary energy consumption. There is thus a delay in 

starting the vehicle blower, depending on the temperature. When switching off the heater, a 

Содержание Thermo Pro 90 HDD

Страница 1: ... corresponding heater integration engine off integration Equipment for hazardous material vehicles ADR The ADR function is provided depending on the equipment We assume that the operation and function has been explained to you by the installing work shop service point to your complete satisfaction In these operating instructions we would like to once again provide you with an overview of safe use ...

Страница 2: ...re stored e g near fuel coal and wood dust grain storage areas dry grass and leaves cardboard boxes paper etc in closed rooms e g garages nor with time pre selection or the Telestart function The heater may not be exposed to storage temperatures above 80 C 120 C excluding control unit If this temperature is exceeded the electronics can be permanently damaged be operated unless the water in the hea...

Страница 3: ...ve signal are requested for this purpose In vehicles of type FL the heaters are automatically switched off and the maximum ADR after running time is 40 s in accordance with the legal specifications An ADR afterrunning period takes place if the generator signal D is discontinued or the auxiliary drive signal e g pumping device is present After the end of the ADR afterrunning period the control unit...

Страница 4: ...f residual heat is auto matically activated When use of residual heat is activated the coolant pump for the heater and the vehicle blower are automatically actuated Deactivation Deactivation of the use of residual heat is carried out automatically by the heater control unit Control elements The Thermo Pro 90 HDD can be fitted with various control elements 2 Switch example 1 MultiControl or SmartCo...

Страница 5: ...ault code is output by a sequence of long flash pulses The long flash pulses must be counted This number fault code provides information to the workshop about the type of malfunction on the heater If a fault code is displayed please contact your authorised Webasto dealer The work shop can use the fault code to narrow down the problem The workshop also has the option of carrying out detailed troubl...

Страница 6: ... leaflet or the website of the respective Webasto represen tative of your country Ident No 9031790B 02 16 Errors and omissions excepted Printed in Germany Webasto Thermo Comfort SE 2016 Webasto Thermo Comfort SE Postfach 1410 82199 Gilching Germany Visitors Address Friedrichshafener Str 9 82205 Gilching Germany Internet www webasto com ...

Отзывы: