- 10 -
Press
or
to check below parameters , press
to check the data of selected parameter,
press
again to return back. Press
to return back the main interface.
Parameter
Name
Range
P01
Return water temp. difference
1
℃
~18
℃
P04
Desired water temp. under cooling
8
℃
~28
℃
P05
Desired water temp. under heating
15
℃
~40
℃
P06
High exhaust temp. protection value
80
℃
~125
℃
P07
Exhaust temp. recovery value
50
℃
~100
℃
P09
Inlet water temp. compensation
-5
℃
~15
℃
P11
Accumulated running time of Compressor
20~90MIN
P12
Piping temp. of enter defrosting
-15
℃
~-1
℃
P13
Defrosting period
2~20MIN
P14
Piping temp. of exit defrosting
1
℃
~40
℃
P15
Difference of ambient temp. and piping temp.
0
℃
~15
℃
P16
Ambient temp. of enter defrosting
0
℃
~20
℃
ATTENTION!
The logic of Inverter pool heat pump is much more complicated than the traditional ON/OFF system, we do
advise not to adjust the key parameters which may affect the reliable operation of the unit.
5.7 Manual defrosting
When piping temp. Is lower than Parameter P12, hold
and
for 3 seconds to enter Manual
defrosting function.
5.8 Factory setting recovery
Hold
and
for 10 seconds to recover factory setting.
Содержание WMIP-003
Страница 2: ......
Страница 9: ... 7 4 Electrical wiring 4 1 Swimming pool heat pump wiring diagram ...
Страница 19: ... 17 7 Connection finished App Main Interface ...
Страница 28: ... 26 4 Elektrische bedrading 4 1Bedradingsschema ...
Страница 39: ... 37 7 Verbinding voltooid en app hoofdinterface ...
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ...14400003000544 ...