NOTE: The  rst diagnostic blink indicates the strength of the 2
AAA lithium batteries in the RFS5. A Red blink would indicate a
need to replace the batteries. Capable life for the lithium
batteries is 10 years. If the 2nd and 3rd blinks are Red,
replacement of the weather station is required.
NOTE: A separate RFS5 weather station is required for each
ProLine® controller that you are installing.

Step 3: Conduct communication range

Press the rain spindle wick for 15 seconds and go to the ProLine®
controller. If you have RF communication, the antenna icon on the
ProLine® display should be blinking.

NOTE: The blinking will continue for 5 minutes after any communication from the RFS5. After 5 minutes,
the antenna icon will remain static until the next communication. Press the Mode button and place the
ProLine® into the Rain/Freeze Sensor position. If the installation is successful, you will have a Green light
at Rain/Freeze Sensor. In addition, the operating panel on an PL1600 or PL4800 must be closed so that
AC is present. You will get a communication error if the panel is showing NO AC.

Step 4: Choosing a location and Mounting the RFS5

1. Decide on a good mounting location for your RFS5 wireless

rain/freeze sensor. The mounting location should be one that is
not a ected by a heat source such as an air conditioner, hot
roof, hot asphalt, etc. Mount in an area with unobstructed
air ow. Mounting is preferred in direct sunlight with good air

ow. Additionally, the location must have open access to

rainfall (cannot be covered by any overhead obstruction such
as trees, roofs, etc.). Mount the RFS5 as close as possible to the
controller. Obstacles such as earth, hills, walls or other
structures will reduce the maximum operating range of the
RFS5. Use the diagnostic LED in the RFS5 to verify
communication and to check operating range at a speci c
location. Extreme conditions may prevent wireless communication.

2. Attach mounting bracket to a smooth surface using the two mounting screws (supplied) or attach to

gutter using the wing nut provided. You may choose to remove the mounting bracket from the bracket
arm for easier installation. Make sure the RFS5 is  xed in a vertical position. Tighten all wing nuts to make
sure unit is held vertical.

Rain/Freeze Sensing Function

The SLW5 wireless weather station provides rain and freeze sensing
functions to prevent watering during periods of rain and The RFS5
wireless rain/freeze sensor provides rain and freeze sensing functions to
prevent watering during periods of rain and freezing weather. The rain
override will pause watering after a minimum of 1/4 inch (6.35mm) of
rainfall is received, based on the 1/4 inch (6.35mm) factory rain sensor
setting. Settings can be changed incrementally up to 3/4 inch (19mm).

Содержание RFS5

Страница 1: ...ousing Insert the RFSHUB 5 into the mating pin connector holes Be careful not to bend the connecting pins Secure the RFSHUB 5 to the housing with the supplied flathead machine screw The RF antenna will hang down inside the 1600 or 4800 housing On the 800 model allow the RF antenna to hang underneath the controller Make sure AC power is supplied to the ProLine controller and then proceed to Step No...

Страница 2: ...a heat source such as an air conditioner hot roof hot asphalt etc Mount in an area with unobstructed airflow Mounting is preferred in direct sunlight with good air flow Additionally the location must have open access to rainfall cannot be covered by any overhead obstruction such as trees roofs etc Mount the RFS5 as close as possible to the controller Obstacles such as earth hills walls or other st...

Страница 3: ...wireless weather station is designed for years of maintenance free operation You will need to change the two AAA lithium batteries after approximately 10 years of operation See instructions under Changing Lithium Batteries Changing Lithium Batteries To change the RFS5 wireless weather station batteries 1 Loosen the bottom cover screws on the RFS5 and rotate the cover in the keyholes and remove the...

Страница 4: ...the following two conditions 1 This device may not cause harmful interference 2 This device must accept all interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Отзывы: