Installation Procedure
1) Switch off mains electrical supply.
2) Check that rating shown on luminaire label conforms
with mains electrical supply.
3) Feed mains cable
C
into pole
D
, while setting luminaire
assembly in position. Tighten screws
B
.
4) Trim mains supply cable
C
to the desired length
and connect leads to their respective terminals at
the base of pole (L = Phase, N = Neutral,
= Earthing)
Installation
The product must be installed and maintained by a
VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW
building/construction and/or electrical regulations and
relevant legislation.
The supply cable must be installed inside the pole and
not be exposed to the outside environment.
Warning:
Switch off mains electrical supply prior to
installing and connecting the luminaire.
Notice:
,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
Attention:
The luminaire is factory-sealed and does
not need to be opened during installation.
The installation on site must comply with local and/or
national health and safety regulations.