background image

4

Installation Procedure

Installation – Pole

1)  Switch off mains electrical supply.

2)  Check that rating shown on luminaire label conforms 

with mains electrical supply.

3)  Feed mains cable 

C

 into column 

D

, while setting 

bracket/luminaire assembly in position. Tighten 

screws 

E

4)  Trim mains cable 

C

 to the desired length and con-

nect the leads to their respective terminals at the 

base of the pole (L = Phase, N = Neutral,  

 = Earthing) 

Installation – Wall bracket

1)  Switch off mains electrical supply.

2)  Check that rating shown on luminaire label conforms 

with mains electrical supply.

3) Access mounting 

ƃ

ange 

J

 by loosening screws 

K

.

4)  Determine positions for 

Ƃ

xing screws 

L

. Ensure 

arrow mark 

R

 on 

ƃ

ange 

J

 aims upwards. Drill rele-

vant holes and insert wall plugs 

M

.  

Warning:

 Ensure not to damage any electric cable, 

water pipe or other devices while drilling holes.

5)  Feed mains supply cable 

N

 (and second cable for 

through wiring, if required) through packing ring(s) 

O

, while setting and securing mounting 

ƃ

ange 

J

 

in position. The pre-installed packing ring(s) 

O

 are 

suitable for cable diameters 7 to 9.5 mm. For larger 

cable diameters (9.5 to 12 mm) use the auxiliary 

packing ring(s). Tighten pressure screws 

S

.  

To secure mounting 

ƃ

ange 

J

, insert screws 

L

, and 

tighten.

6)  Connect mains supply cable 

N

 to the respective 

terminals in terminal connectors 

P

 (L = Phase,  

N = Neutral,   = Earthing)

7)  Position luminaire/wall bracket 

Q

 by attaching 

to mounting 

ƃ

ange 

J

 and secure in position by 

tightening screws 

K

.

Содержание RMC320 LED

Страница 1: ...standards For comprehensive protection of a luminaire installation against lightning and electrical surges it is essential to cover mains supply and data input lines at the distribution board level b...

Страница 2: ...the product s exterior surfaces no special maintenance work is required Do not use high pressure cleaners In case of component failure due to abnormal circumstances or at end of life replacement must...

Страница 3: ...20 105 9846 Short bracket Galvanised steel For lateral mounting on a pole RM1 S for RMC320 105 9845 Single bracket RM1 76 for RMC320 105 9847 AMW C Wooden pole RM1 76 for RMC320 105 9849 AMF C Steel p...

Страница 4: ...itch off mains electrical supply prior to installing and connecting the luminaire Notice If the luminaire is modi ed by anybody other than the original manufacturer then the warranty will no longer be...

Страница 5: ...tions for xing screws L Ensure arrow mark R on ange J aims upwards Drill rele vant holes and insert wall plugs M Warning Ensure not to damage any electric cable water pipe or other devices while drill...

Страница 6: ...5 Installation to a Pole...

Страница 7: ...6 Installation Wall bracket Individual wiring Through wiring ON OFF or WE EF Control Advanced...

Страница 8: ...fo switzerland we ef com WE EF LIGHTING United Kingdom Tel 44 844 880 5346 Fax 44 844 880 5347 info uk we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 info asiapaci c we ef com W...

Отзывы: