4
Installation Procedure
The luminaire is suitable for installation directly
on to an even surface, however it is recommended
to incorporate the provided anchor bolts or optional
planted root to ensure maximum stability.
Installation – KTX
6ZLWFKRĪPDLQVHOHFWULFDOVXSSO\
2) Check that rating shown on luminaire label conforms
with mains electrical supply.
3) (if using planted root mounting accessory)
A suitable recess to be provided for planted root A.
(QVXUHWKDWDVROLGIRXQGDWLRQDVZHOODVVXĩFLHQW
mains cable length are provided.
Note: Planted root installation instruction is
available at the end of this document.
4) Remove head of luminaire H from bollard post
B after loosening screw J with Torx T-20 tool and
rotating it anti-clockwise until it can be lifted up.
5) Set bollard post B in position and secure by insert-
ing and tightening provided mounting fasteners I.
The direction of light for KTX [R65] is opposite the
set screw J.
6) Connect luminaire cable E to mains supply cable F
in watertight terminal connector G (not supplied by
WE-EF):
a) ON/OFF (L = Phase, N = Neutral, = Earthing)
b) 0-10V (L = Phase, N = Neutral, = Earthing,
D-/D+ = 0-10V control line).
7) Place watertight terminal connector G and excess
cable inside bollard post B.
8) Return head of luminaire H to bollard post B and
secure by tightening screw J.