4
Installation Procedure
Installation – RAIL66 version
Prior to installing the luminaire, mount and connect
the selected RAIL66 mounting system in accordance
with relevant installation instructions
1) Switch off mains electrical supply.
2) Check that rating shown on luminaire label conforms
with mains electrical supply.
3) Determine desired position of luminaire
A
on rail
X
,
dependent on aiming requirements and proximity
to a suitable mains outlet
Y
.
4) Attach clamp
B
to rail
X
. Tighten wingnut
C
.
5) Remove protective cover
Z
from mains outlet
Y
.
Insert in-line connector
G
and tighten.
Attention:
On any mains outlet
Y
’ that is not used,
protective cover
Z
’ must remain
Ƃ
rmly secured.
Check and ensure proper
Ƃ
t and tightness.
6) Loosen screws
H
and
I
slightly. Aim luminaire in
desired direction, tighten screws
H
and
I
. Tighten
set screw
O
.
Installation – Space frame version
Suitable for space frame diameter 48-60 mm.
1) Switch off mains electrical supply.
2) Determine desired position of luminaire
A
on space
frame
X
, dependent on aiming requirements.
3) Attach clamp
B
to space frame
X
. Tighten
wingnut
C
.
4) Detach gear box cover
D
by loosening screws
S
.
5) Check that rating shown on luminaire label conforms
with mains electrical supply.
6) Feed mains supply cable
F
through cable gland
G
(Fig. I).
7) Connect mains supply leads to respective terminals
in terminal connector
J
(N = Neutral, L1 = Phase,
= Earthing). Tighten cable gland
G
.
For 1-10 V analogue dimming interface, connect
main supply leads to respective terminals in termi-
nal connector
J
(N = Neutral, L= Phase,
= Earthing) and (D+, D– = external 1-10 V dim-
ming device). See Fig. II. Tighten cable gland
G
.
8) Reposition gear box cover
D
and secure in position
by tighten screws
S
.
9) Loosen screws
H
and
I
slightly. Aim luminaire in
desired direction, tighten screws
H
and
I
. Tighten
set screw
O
.
Содержание FLD121
Страница 6: ...5 RAIL66 version...
Страница 7: ...6 Space frame version Fig I Feed mains supply cable through cable gland...