3
Light Source
LED
Maintenance
Apart from cleaning the product’s exterior surfaces, no special maintenance work is required.
Do not use high-pressure cleaners.
In case of component failure due to abnormal circumstances or at end of life, replacement must be carried out
E\DVXLWDEO\TXDOLƂHGDQGWUDLQHGSURIHVVLRQDO
Warning:
Do not open luminaire while mains supply is switched on.
)RURSHUDWLRQDVFRORXUFKDQJHUWKHƃRRGOLJKWVRIWKH)/&&&VHULHVUHTXLUHD'0;FRQWUROVLJQDO
(DALI on request). The operation without control signal may lead to error.
For operation with Tunable White, a DALI DT8 controller is required.
Do not stare at the operating light source.
For eye safety, the following requirement applies to luminaires with a colour
temperature of 4000K in combination with light beam [EE] / [EES]:
The luminaire should be positioned so that prolonged staring into the luminaire at
a distance closer than 2.8 m / 3.4 m is not expected.