background image

4

Lamp Replacement and Maintenance

Do not open the luminaire during operation or while

mains electrical supply is switched on!

1) Switch off the mains electrical supply. 

2) Loosen screws 

D

, twist cover 

E

to the left and take 

it off.

3) If reflector 

F

is supplied it might be necessary to 

remove the reflector by loosening of the screws 

G

.

4) Clean all exterior surfaces, if necessary by using a 

wet cloth with mild detergent.

5) Check gaskets for damage and replace if necessary.

6) Replace lamp. 

(Compare the local voltage and frequency with the data

mentioned on the label of the luminaire). 

If required reposition reflector.

Protect our environment: Discard used lamps in compliance

with the most recent environmental legislation.

Lampenwechsel und Wartung

Leuchtengehäuse nicht während des Betriebes öffnen!

1) Spannungsfreiheit der Anschlussleitung herstellen. 

2) Schrauben 

D

lösen und die Abdeckung 

E

nach links

drehen und abnehmen.

3) Bei Versionen mit Reflektor 

F

kann es notwendig wer-

den, diesen durch das Lösen der Schrauben 

G

zu 

entfernen.

4) Abdeckung mit geeigneten Reinigungsmitteln säubern.

5) Dichtungen auf Funktionsfähigkeit überprüfen und

gegebenenfalls austauschen.

6) Lampe einsetzen. Lampentyp und Lampenleistung 

müssen mit den Angaben auf dem Leistungsschild

übereinstimmen. Gegebenenfalls den Reflektor wieder

befestigen.

Für die Entsorgung der Lampe sind die zur Zeit gültigen

Umweltgesetze zu beachten.