operation manual SAUNA-VII (07/12)
page 8 of 14
The dosing unit SAUNA PLUS VI is delivered in a state ready for operation.
It has to be mounted on place that is accessable easily and a bit higher
than the oven.
The installed security device according to DIN 1988 is useable for
non-toxical fragrances for sauna splashs. A second pre-condition is
a free outlet.
If the tubing tends upwards to the oven a more significant security
device (tube cutter) has to be installed. If demanded the tube
cutter (article no. 14872) can also be pre-installed ex works. The
connection for the water supply at the ball valve is ½”, for the splash
tubing 3/8".
The fragrance canister has to be filled and the suction tube has to be hung
into it so that its end reaches the bottom of the canister.The roller of the
pump is packed seprately for transport and stock-taking to prevent a
deformation of the dosing hose. Insert the roller before taking the unit into
operation (see 3.1).
4.2
Electrical connection
To prevent that there is a dosing off-time of the sauna operation time, the
electric connection (power socket 230V) has to be locked by the controller
for the sauna oven.
The first splash comes after app. 30 minutes after the overplugging of the
voltage.