![WDT GRANUDOS Flex-CPR Touch XL Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/wdt/granudos-flex-cpr-touch-xl/granudos-flex-cpr-touch-xl_operating-instructions-manual_4526866020.webp)
Dosing unit GRANUDOS Type Flex-CPR Touch XL,
Type Flex-Touch and Type Flex-S5
Index: 01 Change date: 11/10/2023
OI No.: BA SW 022-01 Granudos Flex Dosiereinheit EN.docx
Page 20 of 68
3.2.8
Buffer tank with/without collecting tub (only for CPR Touch XL and Touch) (option)
Overview buffer tank
Key buffer tank
Description
1.
When the buffer tank’s lower control level “Start filling” is reached, the solenoid valve to the swim-
ming pool filter system closes and the solenoid valve for buffer tank filling opens. Buffer tank filling
starts.
2.
At the buffer tank’s upper control level “Stop filling”, the filling is stopped. This is followed by a
flushing cycle to clean the dissolving unit: initially for 20 seconds with acid, followed by 20 seconds
with water only. Afterwards, the solenoid valves switch back to normal operation.
3.
At the buffer tank’s “Minimum alarm” level, the dosing pump(s) are switched off. An alarm mes-
sage is shown on the display; the alarm output is active.
4.
At the buffer tank’s “Maximum alarm” level, an alarm message is shown on the display. The dosing
pump(s) continue(s) running.
Contact positions
When the container is half full, the level switches’ contacts are set as follows:
Level position
Contact
Maximum level alarm
closed
Maximum level
open
Minimum level alarm
open
Minimum level
open
An activated carbon filter (61) is screwed on top of the buffer tank. It is used to clean the chlorine-
containing air when filling the buffer tank and for venting and aerating.
The buffer tank is located in the collecting tub. An alarm switch (65) for leakages is installed in the
collecting tub.
61.
Activated carbon filter
62.
4-fold level switch
a)
Maximum level alarm;
b)
Maximum level; stop filling
c)
Minimum level; start filling
d)
Minimum level alarm;
63.
Buffer tank 300 l PE
64.
Collecting tub buffer tank (not shown)
65.
Alarm switch for collecting tub buffer tank,
(not shown)
Figure 14: Buffer tank
a)
b)
c)
d)
Содержание GRANUDOS Flex-CPR Touch XL
Страница 74: ......