background image

Dosing Device Foamdos V6

 

 
 

Index:  00 

Date modified: 18/05/2021 

OI No.: BA DW 025-00 Foamdos V6 EN.DOCX 

Page 7 of 37

 

3

 

Product description - scope of delivery 

3.1

 

Scope of delivery / accessories 

 

Micro-processor control unit UNPL inside the control housing 

 

Diaphragm air pump 7006 AC  

 

Inlet with ball valve 1/2” JG and filter MS 1/2” 

 

System separator in accordance with EN1717  

 

Pressure reducer for regulating the system pressure 

 

Needle valve for regulating the water flow during foam generation 

 

2 solenoid valves 3/8” (for flushing and foam generation) 

 

Foam generator for foam generation 

 

Peristaltic pump SA 

 

Suction lance d 12-420 mm 

 

2 x dosing valve for foam concentrate and air 

 

Hose PVC 12 x 1.5 transparent for foam dispenser 

 

Button plate 2 x with 2 Piezo push buttons and flush-mounted box 

 

Completely pre-assembled and pre-wired on mounting plate PP grey  

 

Transition nipple for foam line from 3/8” to ½” 

 

On-site services 

 

Technical room/ cabinet for installation of the control panel; alternatively: Installation below the massage 

table 

 

Isolated ground socket; recommended: VDE B12 fuse 

 

Thermostatic mixer / water connection mixed water 1/ 2” 

 

Required pressure at the transfer point: min. 1.5 bar flow pressure 

 

Water volume: approx. 10 l/min 

 

Drain DN40 / gully in the technical room 

 
Accessories/ options 

 

Thermostatic mixer for the correct water temperature during the flushing function 

 

Hand-held shower head for foam outlet 

     

 

Shower head hose 

 

Drain valve (solenoid valve) 
 

3.2

 

Product description 

The  FOAMDOS  dosing  device  produces  a  massage  foam  from  the  3  components  water,  air  and  foam 

concentrate, which is applied to the guest during hammam massages. The massage foam can also be used for 
body care during the steam bath. A flushing function is integrated. The water flow and thus the consistency of 
the applied foam can be individually adjusted on the device by means of a needle valve.  
Foam  generation  and  flushing  can  be  switched  on  and  off  separately  at  the  external  button  plate.  After 

switching off the flushing, the compressor continues to run for a preset time in order to blow empty the line 
(optionally adjustable). 
Settings in the programme can be made on the LCD display. 

Содержание Foamdos V6

Страница 1: ...Article no 27165 OI No BA DW 025 00 Foamdos V6 EN DOCX Language EN Operating Instructions Dosing Device Foamdos V6 Massage foam for hammam massages...

Страница 2: ...n site 13 4 2 Installation instructions suggested installation 13 4 3 Mechanical installation 13 4 3 1 Install mounting plate with control unit 13 4 3 2 Install the button plate 13 4 4 Hydraulic insta...

Страница 3: ...30 9 2 Wiring Diagram 31 9 3 Commissioning protocol instruction 32 9 4 Operation data sheet 33 9 5 Maintenance protocol 35 9 6 Spare parts list wear parts list list of consumables 36 10 Appendices 37...

Страница 4: ...derstood these operating instructions Electrical connection work may only be carried out by appropriately trained specialists 1 3 Symbols used This document uses the following types of safety notices...

Страница 5: ...r and tear For these we assume a warranty of 1 2 year Our merchandise management programme requires an invoice for each delivery including warranty services When returning a defective component upon r...

Страница 6: ...protective clothing Observe the warning notices on the device 2 2 1 Handling of chemicals risks to humans and the environment Important information concerning the handling of chemicals and fragrances...

Страница 7: ...natively Installation below the massage table Isolated ground socket recommended VDE B12 fuse Thermostatic mixer water connection mixed water 1 2 Required pressure at the transfer point min 1 5 bar fl...

Страница 8: ...iping to foam dispenser 10 Dosing valve foam concentrate with hose line 11 Dosing valve air with hose line 12 Solenoid valve flushing 13 System separator with connection for drain d40mm 14 Connection...

Страница 9: ...mp for damage according to the maintenance protocol or each time you refill the foam concentrate 3 2 2 Control unit The control unit consists of a housing with openings on the side for cooling the bui...

Страница 10: ...delivery container the canister lid of the delivery container can be used 3 2 7 Drain valve accessory If the technical room is located on a floor below a drain valve solenoid valve can be installed t...

Страница 11: ...30VAC 50Hz 150W safety plug Fuse F500 2A slow D8 3x8 on NT35 Nominal pressure house connection min 1 5barg max 8 barg Recommended operating pressure at the pressure reducer Max 4 barg Required duct co...

Страница 12: ...only be transported and stored in its original packaging Please ensure careful handling For transport and storage purposes the roller carrier of the dosing pump is not mounted This prevents the hose...

Страница 13: ...ation 4 3 1 Install mounting plate with control unit Install the FOAMDOS dosing device at working level in the technical room It is also possible to install the dosing device below the massage table 1...

Страница 14: ...ice to the house water line This must be recorded by the installer in a handover protocol To prevent limescale deposits we generally recommend using softened water 4 German hardness Installation plan...

Страница 15: ...l mounting bend 2 Foam line with drain valve If the foam line must be installed at an incline and exceeds a length of 1m the use of a drain valve accessory is recommended Install the foam line with br...

Страница 16: ...discharge himself for at least 5 seconds For example by touching an earthed system part or by wearing an ESD antistatic wrist strap connected to an earth wire 4 5 1 Open close the housing The housing...

Страница 17: ...re that the device has been correctly installed and connected 5 2 1 Prepare the foam concentrate 1 Place the canister with the foam concentrate under the device 2 Remove the canister lid 3 Place the s...

Страница 18: ...the entire hose is contained in the casing Now replace the safety disc and the transparent pump cover This completes the installation of the roller carrier The dismantling of the roller carrier and t...

Страница 19: ...rotating peristaltic pump Operation with the protective cover 31 removed is prohibited 6 2 Control unit Software The control unit is operated via the device s control unit display with 3 buttons The...

Страница 20: ...imes for the foam time and flushing time Standby operational readiness If no input occurs for 60 seconds the backlighting is dimmed Standby mode Pressing a key ends the Standby mode 6 4 Button plate f...

Страница 21: ...control in order to narrow down possible faults For test functions the time is set to 20 seconds and cannot be changed The test function can be prematurely cancelled with the Enter key 6 5 1 Foam tim...

Страница 22: ...ontrol Start flushing with water Function The Flush solenoid valve opens The control LED on the solenoid valve lights up 6 5 7 Test SV foam Only for function control Open the Foam solenoid valve Funct...

Страница 23: ...e accessory emptying foam line This menu only appears when Emptying foam line is activated see above Input of emptying time in seconds 6 5 13 Emptying type accessory emptying foam line This menu only...

Страница 24: ...er menu The menus for the user can be protected with a password All menus that can be protected with a password are protected together The menus cannot be protected individually ON Protect menus with...

Страница 25: ...am becomes more liquid 6 7 Replenish consumables Replace the canister with foam concentrate a Unscrew the lid of the new canister b Place the suction lance in the canister c Screw the suction lance s...

Страница 26: ...ar cleaning of the device 2 Stocking of the consumables 3 Testing and maintenance in accordance with the maintenance protocol in Chapter 9 5 7 1 1 Check change hose kit The hose in the peristaltic pum...

Страница 27: ...age the hose nipples 3 Push the new dosing hose onto the hose nipples so that the markings on the hose ends are located in the front This ensures that the hose is not twisted 4 Attach the hose ends us...

Страница 28: ...supply Device not functioning Incorrect setting Fuse defective Control circuit board defective Check reset settings Renew fuse Renew circuit board Solenoid valve without function Fuse defective Solen...

Страница 29: ...f in doubt information may be obtained from the institution responsible for disposal at your location If this is not possible dispose as hazardous waste 8 2 Decommissioning Switch off the device at th...

Страница 30: ...Dosing Device Foamdos V6 Index 01 Date modified 30 08 2019 OI No BA DW 025 00 Foamdos V6 EN DOCX Page 30 of 37 9 Documents 9 1 Declaration of conformity...

Страница 31: ...Foamdos V6 Index 01 Date modified 30 08 2019 OI No BA DW 025 00 Foamdos V6 EN DOCX Page 31 of 37 9 2 Wiring Diagram Notice for wiring diagrams The wiring diagrams can also be found near the device s c...

Страница 32: ...V6 EN DOCX Page 32 of 37 9 3 Commissioning protocol instruction This protocol is to be completed by the commissioning technician Without a completed and signed commissioning protocol all warranty clai...

Страница 33: ...s 20 s Emptying Yes No yes Empty time 3 s 0 30 s yes Empty type SV or compressor Contrast 8 0 15 yes Password protection for user menu ON ON OFF Sequence when switching on directly according to facto...

Страница 34: ...pty type SV or compressor Contrast 8 0 15 yes Password protection for user menu ON ON OFF Sequence when switching on directly according to factory settings Operation data sheet master copy Parameter F...

Страница 35: ...ied 30 08 2019 OI No BA DW 025 00 Foamdos V6 EN DOCX Page 35 of 37 9 5 Maintenance protocol Carry out the specified maintenance tasks in order to protect any warranty claims The maintenance protocol i...

Страница 36: ...4259 Safety disc grey 13633 Hose kit 4 8x1 6 13414 Hose bracket with hose 4 8x1 6 12703 Suction set 12 12278 Dosing valve air 3 8 20503 Dosing valve foam concentrate 3 8 20502 Diaphragm pump 24269 Sol...

Страница 37: ...Index 01 Date modified 30 08 2019 OI No BA DW 025 00 Foamdos V6 EN DOCX Page 37 of 37 10 Appendices Commissioning protocol Maintenance protocol Supplementary sheet BB DW 001 Installation flush mounte...

Страница 38: ......

Страница 39: ...ment 1 Commissioning 1 1 Device checked for correct installation 1 2 Commissioning conducted according to Operating Instructions Chapter 5 1 3 Thermostatic mixer option set 1 4 Control parameters adju...

Страница 40: ......

Страница 41: ...3 Month 4 Month 5 Month 6 Month 7 Month 8 Month 9 Month 10 Month 11 Month 12 Comment additional tasks 1 Water supply part 1 1 Check device for leaks 3 1 2 Activate valves check for function and leaks...

Страница 42: ......

Страница 43: ...recess to sink the sealing flange with a depth of 3mm Dimensions 1 fold HxW min 130x97mm 2 fold HxW min 163x97mm 3 fold HxW min 196x97mm 4 fold HxW min 229x97mm d Break out an orifice for the empty co...

Страница 44: ...uilding foam in the wall approximately 20 mm protruding due to flush system Insert cable d Install the supplied construction protection cap in the flush mounted box e Plaster the brickwork so that the...

Отзывы: