GRANUDOS S5, control unit
Index: 02
Date modified: 11/05/2021
OI No.: BA SW 014-02 Granudos S5-Steuereinheit EN.docx
Page 14 of 29
If a wrong password is entered, the display colour changes to red, and the password must be re-entered.
Only certain predefined menu areas require a password to be entered. The password is automatically queried
in these areas. The respective areas are:
Reset
Dust extraction
Delay booster pump
Config. Cl
Config pH
Control
Input inverse
Once the password has been entered, all other password-protected menu areas are also activated. The
activation ends once the user switches back to the start menu.
NOTICE!
Please store the individually chosen passwords safely in the operation data sheet. Lost
passwords can only be reset by the factory customer service!
Reset
This process can only be performed by entering the password.
All of the set parameters are reset here to the ex-works settings.
The ex-works settings are listed in the operation data sheet
in Chapter 9.4
Tip!
First note down operation settings in the operation data sheet!
Main menu
Settings
Dust extraction (optional), (password entry)
This process can only be performed by entering the password.
The dust extraction parameters are set here. The extraction begins with the start of the
chlorine dosing and runs until the end of the run-on time.
Set
delay time
, 0-60 sec, 0 = dust extraction deactivated; after completion of the
chlorine dosing, the dust extraction continues to run for the set amount of time.
Set
flushing time
1-5 sec. for the transparent hose (optional); the flushing valve
opens for the set amount of time and the transparent hose is cleaned.
Set
flushing interval
0 - 48 hrs (optional); the flushing interval is the time between
two flushing cycles.
Main menu
Settings
Delay Booster pump (password entry)
This value can only be set by entering the password.
This function is only active when the GRANUDOS is switched off externally for filter
flushing via the CCT. Once the GRANUDOS has been switched on again, the booster
pump is started with the set delay time. This ensures that no air remains in the supply
line to the GRANUDOS, which could lead to faults in the b-pump.