background image

FAX:   (86)755-83849434         Web:

nical Support Department during business hours (8:30 A.M.–5:30 

repair, you may contact our Product Services Group .

NET 300 Series Start-Up Guide

If return of the equipment is necessary, please contact the WDS Tech-

 www.sinosun.cn

Phone: (86)755-83849417  E-Mail: 

P.M. Beijing Time). When calling, please give the complete model 

Technical assistance for WDS products is available from our Tech-

20

i

TECHNICAL ASSISTANCE

number of the radio, along with a description of the trouble 
symptom(s) that you are experiencing. In many cases, problems can be 
resolved over the telephone, without the need for returning the unit to 
the factory.

FACTORY SERVICE

nical Support Team. You will be issued a Service Request Order 
(SRO) number. The SRO number will help expedite the repair so that 
the equipment can be repaired and returned to you as quickly as pos-
sible. Please be sure to include the SRO number on the outside of the 
shipping box, and on any correspondence relating to the repair.

 No 

equipment will be accepted for repair without an SRO number.

A statement should accompany the radio describing, in detail, the 
trouble symptom(s), and a description of any associated equipment 
normally connected to the radio. It is also important to include the 
name and telephone number of a person in your organization who can 
be contacted if additional information is required.

The radio must be properly packed for return to the factory. The orig-
inal shipping container and packaging materials should be used when-
ever possible. All factory returns should be addressed to:

When repairs have been completed, the equipment will be returned to you by 
the same shipping method used to send it to the factory. Please specify if you 

wish to make different shipping arrangements. To inquire about an in-process 

 

Shenzhen Sinosun Technology Co., Inc.

Customer Service Department

3A17,South Plaza Cangsong Building, Tairan Industry & Trade  Zone

Futian District, Shenzhen,Guangdong, China

[email protected]

Содержание iNET 300 Series

Страница 1: ...iNET Start Up Guide Wireless IP Ethernet Transceiver 300 Series...

Страница 2: ...tenna 7 Step 3 Measure Connect DC Power 7 Step 4 Review the Transceiver s Configuration 8 Step 5 Connect the Data Equipment 9 Step 6 Check for Normal Operation 10 Resetting to Factory Defaults 11 Perf...

Страница 3: ...stallation in Hazardous Locations The transceiver is not acceptable as a stand alone unit for use in hazardous locations It must either be mounted within another piece of equipment which is certified...

Страница 4: ...posal These systems will reuse or recycle most of the materials found in this equipment in a sound way this equipment About This Guide This guide presents installation and initial operating instructio...

Страница 5: ...This is accom plished with an Authorization Key purchased from the factory Each one of these individual software keys is associated with the serial number of the corresponding unit Transceivers serve...

Страница 6: ...tion INSTALLATION PLANNING This section provides steps for installation and start up of the equip ment General Requirements There are three main requirements for installing the transceiver They are ad...

Страница 7: ...ed that the Access Point unit be installed first With this plan you can quickly check the operation of each associated Remote as it is placed on the air NOTE Transceivers are shipped from the factory...

Страница 8: ...2 Amperes A power connector with screw terminals is provided with each unit Strip the wire leads to 6 mm 0 25 Be sure to observe proper polarity as shown in Figure 1 with the positive lead on the lef...

Страница 9: ...the signal the higher the data rate Available data rates are 256 kbps and 512 kbps Password Used for remote access and Menu System features NOTE The default password is admin For web access a usernam...

Страница 10: ...s Guide Step 5 Connect the Data Equipment Ethernet Example a Connect Ethernet compatible data equipment to the trans ceiver s LAN port 10BaseT Use a straight through Ethernet cable to connect the LAN...

Страница 11: ...t you are installing send a PING command to it through the LAN port This verifies basic LAN connectivity b If you have already installed a Remote unit try sending a PING to that unit through the Menu...

Страница 12: ...e network is operating properly based on observation of the unit s LEDs connect a computer to the transceiver s data port that will be used by the local terminal equipment Send the PING command to ver...

Страница 13: ...stics retry packet counter is unacceptably high several techniques can be used to improve it These include iden tifying interference and taking corrective steps such as skipping some radio frequencies...

Страница 14: ...he Commit Changes selection is invoked Commit Changes This re boots the radio and loads the active chan nels into the frequency list for frequency hopping operation AIMING DIRECTIONAL ANTENNAS In gene...

Страница 15: ...he stronger the sig nal 5 View the Wireless Packets Dropped and Received Error rates at the point of maximum RSSI level They should be the same or lower than the previous reading Main Menu Performance...

Страница 16: ...and unkey the transmitter ON and OFF Enable Disable 5 Measure the forward and reflected power into the antenna system and calculate the SWR The ratio should be less than 2 1 The power output level sho...

Страница 17: ...n Page 17 pro vides guidance using the Menu System as a tool If problems persist shooting help service information and recent software firmware updates at ment See TECHNICAL ASSISTANCE on Page 20 for...

Страница 18: ...at the appropriate type of Ethernet cable is used straight through or crossover as required Table 5 Troubleshooting with the Menu System Symptom Problem Recommended System Checks Remote does not assoc...

Страница 19: ...t to PING an IP unit attached to another radio d If successful with the LAN PINGs try connecting to a known unit in the WAN Wireless Retries too high Possible Radio Frequency Interference a If omnidir...

Страница 20: ...dc Size Excluding mtg hardware 1 5 x 8 x 4 H x W x D Weight 0 9 kg 2 lb 1 2kg Case Cast Aluminum RADIO CHARACTERISTICS GENERAL Frequency Range 336 344 MHz Industrial Scientific Medical ISM Band Mode F...

Страница 21: ...he SRO number on the outside of the shipping box and on any correspondence relating to the repair No equipment will be accepted for repair without an SRO number A statement should accompany the radio...

Отзывы: