Pre-start checklist.
To avoid damage to the seal, and to maximize seal life observe the
following precautions:
•
Stay within the temperature or pressure limitations specified
for the mechanical seal used.
•
Do not run the pump dry or against a closed valve! Dry
operation will cause seal failure within minutes.
Before starting the pump, the following inspections should be made:
•
All wiring to the motor and starting device should match the
wiring diagram. The motor should move in a clockwise
rotation when looking at it from the back. If the motor has
been in storage for any length of time, whether used or new,
then consult the motor instructions before starting. Use the
motor data plate to check the voltage, phase, and line circuit
frequency.
•
In order to make sure it rotates freely, use your hands to turn
the rotating element..
•
All piping should be checked for leaks. Also all flange bolts
should be checked to make sure they are tightened securely..
•
Write down the serial number of the pump for future
reference.
CAUTION.
Operation of the pump while dry will result in serious
damage.
WARNING.
.
The pump should be operated within the conditions on the
name plate in order to protect the safety of the operator.
If operated
outside such conditions, the pump could fail causing injury to operating
personal.
In order to properly operate and maintain the pump and its
components, an instruction book should be consulted.
Содержание NE 4 113-4-220
Страница 1: ...Operation Manual Submersible Non clog pumps 4 6 NE Series...
Страница 19: ...19 NE Pumps...
Страница 20: ...20 Operation Manual NE 4...
Страница 21: ...21 NE Pumps...
Страница 22: ...22 Operation Manual NE 6...
Страница 28: ...4034 Mint Way Dallas Texas 75237 214 337 8780 support wdmpumps com...