background image

 

 

      

L

L

I

I

F

F

E

E

 

 

I

I

S

S

 

 

P

P

R

R

E

E

C

C

I

I

O

O

U

U

S

S

 

 

-

-

 

 

T

T

H

H

I

I

N

N

K

K

 

 

S

S

A

A

F

F

E

E

T

T

Y

Y

 

 

 

 

1. 

Most accidents can be avoided by using COMMON SENSE. 

2. 

Please read the operation and maintenance instruction manual supplied with the 
pump. If you did not receive one, please call your local distributor before pump 
installation. 

3.  

Do not wear loose apparel that may become entangled in the impeller or other 
moving parts. 

4.  

Always use appropriate safety equipment, such as safety glasses, when working on 
the pump or piping. 

5.  

Pumps build up heat and pressure during operation-allow time for pumps to cool 
before handling or servicing. 

6.  

Only qualified service personnel should install, operate and repair pump. 

7.  

Keep clear of suction and discharge openings. DO NOT insert fingers in pump with 
power connected. 

8.  

Do not pump flammable or hazardous materials (gasoline, acids, alkalis, etc.) 

9.  

Do not block or restrict discharge hose, as it may whip or burst catastrophically 
under pressure. 

10.  

Make sure lifting handles/hooks are securely fastened each time before lifting. 

11.  

Do not lift pump by the power cord under any circumstances. 

12.  

Do not exceed manufacturer's recommendation for optimum performance, as this 
could cause the motor/pump to overheat and lead to premature wear or failure. 

13.  

Secure the pump in its operating position so it does not tip over, fall or slide. 

14.  

Keep away from impeller when power is connected. 

15.  

Submersible Pumps are not approved for use in swimming pools, recreational water 
installations, decorative fountains or any installation where human contact with the 
pumped fluid is common. 

16.  

Do not operate pump without adequate protection and safety devices in place. 

17.  

Always replace safety devices that have been removed during service or repair. 

18.  

To reduce risk of electrical shock, pump must be properly grounded in accordance 
with the National Electric Code and all applicable state and local codes and 
ordinances. 

19.  

To reduce risk of electrical shock, always disconnect the pump from the power  

         source before handling or servicing. 
20.  

Any wiring of pumps should be performed by a qualified electrician. 

21.  

Never operate a pump with a power cord that has frayed or brittle insulation. 

22.  

Cable should be protected at all times to avoid punctures, cuts, and      

 

abrasions - inspect frequently. 

23. 

Never handle connected - "hot" power cords with wet hands. 

24.  

Never operate a pump with a plug-in type power cord without a ground fault circuit 
interrupter, adequate overload and short circuit protection. 

 

IMPORTANT

 !!! MODY Pumps Inc. is not responsible for losses, injury, or death resulting 

from a failure to observe these safety precautions, misuse or abuse of  

pumps or 

equipment. 

 

 

 

 

[email protected] | 13309 Beach Ave. Marina del Rey, CA 90292 | wctproducts.com | Phone:  800-WCT-PROD (928-7763) | Fax: 310-306-9343 

Содержание mody Pumps M-0.5

Страница 1: ...OPERATING INSTRUCTIONS INSTALLATION MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST ISO 9001 Certified info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 2: ...rating position so it does not tip over fall or slide 14 Keep away from impeller when power is connected 15 Submersible Pumps are not approved for use in swimming pools recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common 16 Do not operate pump without adequate protection and safety devices in place 17 Always replace safety d...

Страница 3: ...OF THE PUMP OR THE HEAD AGAINST WHICH THE PUMP IS OPERATING IN mody SUBMERSIBLE SUMP PUMPS ALL WEAR PARTS ARE READILY REPLACEABLE AS NEEDED BOTH WEAR AND ELECTRICITY CONSUMPTION ARE STILL FURTHER REDUCED WHEN THE PUMPS ARE FITTED WITH BUILT IN LEVEL CONTROLS FOR AUTOMATIC STARTING AND STOPPING IT IS HOWEVER RECOMMENDED THAT IRRESPECTIVE OF TYPE OF PUMP ADEQUATE MOTOR PROTECTION SWITCHGEAR SHOULD B...

Страница 4: ...CURELY EARTHED 4 ENSURE HOSE CONNECTION IS CORRECTLY AND SECURELY FITTED 5 ENSURE DELIVERY HOSE IS FREE FROM KINKS AND SHARP BENDS 6 DO NOT LIFT OR PULL THE PUMP UNDER ANY CIRCUMSTANCES BY MEANS OF THE CABLE THE PUMP MUST BE LOWERED LIFTED FROM THE SPACE TO BE PUMPED BY USING A LIFTING ROPE ATTACHED TO THE HANDLE EYEBOLT PROVIDED IN THE PUMP 7 DRY RUNNING OF THE PUMP IS NOT DESIRABLE HOWEVER THE P...

Страница 5: ...O HIGH 3 USE PUMPS IN TANDEM 4 DISCHARGE HOSE TORN 4 USE NEW HOSE 5 LEAKING CRACKED OUTLET 5 REPL OUTLET GASKET TECHNICAL DESCRIPTION THE MODY SUBMERSIBLE PUMP IS IN ITSELF A COMPLETE PUMPING STATION BESIDES A POWER SUPPLY AND A DISCHARGE HOSE NO EXTRA EQUIPMENT IS REQUIRED THE COMPLETE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING GOOD AND SIMPLE SERVICEABILITY THE MAJOR DESIGN FEATURES ARE AS UN...

Страница 6: ...IN CLEARANCES BETWEEN THE WEAR PARTS CABLE GLAND ASSEMBLY REFER DRG THE PUMP IS SUPPLIED WITH 20 FEET CABLE AS STANDARD THE CABLE IS A 3 CORE EPR SHEATHED AND INSULATED CABLE CONFORMING TO INTERNATIONAL STANDARDS THE CABLE IS WATERPROOF AND CAN BE COMPLETELY SUBMERGED IN WATER THE CABLE IS TERMINATED IN THE PUMP AT THE CABLE GLAND THE GLAND ASSEMBLY SEALS THE CABLE ON THE OUTSIDE SHEATH THE CABLE ...

Страница 7: ...ENCY 3 CHECK NAME PLATE FOR OPERATING VOLTAGE AND FREQUENCY OIL SPECIFICATIONS A H P ENKLO OIL 46 48 B SHELL TELLUS 29 C CHEVRON SUPERLA FDA APPROVED WHITE 10 USE NON CONDUCTING NON FOAMING NON DETERGENT OIL ONLY info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 8: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 9: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 10: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 11: ...751306202 Wave washer 2 BWW 6202 SC 28 79362021 Bearing 2 ZZ 6202 29 321FS0040 Shaft Rotor without Bearing 1 166 40 15 SUS 410 30 772431 01 Key 1 4 4 10 SUS 304 31 64901123A Insulating sheet 1 123MM 50 32 311110204E3 B Stator 1 25 60 40L 33 6531114 Shim 1 14MM SC 34 1743125095 Motor frame 1 125 95H SUS 304 35 411026 01 O ring 1 2 62MM 120 3 N 70 36 1936FS0040 Bearing bracket 1 FC 20 37 432214 Mech...

Страница 12: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 13: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 14: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 15: ...ZZ 6202 29 752306202 02 Washer 1 15 23 1T SC 30 321FS0075 Shaft Rotor without Bearing 1 195 60 15 SUS 410 31 772431 01 Key 1 4 4 10 SUS 304 32 64901123A Insulating sheet 1 123MM 50 33 311110206F3 B Stator 1 125 60 60L 34 6531117 Shim 1 17MM SC 35 1743125120 Motor frame 1 125 122H SUS 304 36 79363021 Bearing 1 ZZ 6302 C3 37 411026 01 O ring 1 2 62MM 120 3 N 70 38 1936FS0075 Bearing bracket 1 FC 20 ...

Страница 16: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 17: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 18: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343 ...

Страница 19: ...3 29 752306203 01 Washer 1 M17 39 1T SC 30 321KO0150 Shaft Rotor without Bearing 1 250 5 90 S410 31 772431 01 Key 1 4 4 10 SUS 304 32 64901123A Insulating sheet 1 123MM 50 33 311110209F3 B Stator 1 125 60 90L 34 6531117 Shim 1 17MM SC 35 1743125160 Motor frame 1 125 161H SUS 304 36 79362041 Bearing 1 ZZ 6204 37 457FCS015010 Gasket 1 N 70 38 1936FCS0150 Bearing bracket 1 FC 20 39 411026 01 O ring 1...

Страница 20: ...practice and or our recommendations or instructions The Customer is responsible for communicating all vital information about the application and use of the product THE SOLE AND EXCLUSIVE REMEDY FOR A VALID CLAIM ON ANY AND ALL PRODUCT WARRANTIES SHALL BE PRODUCT REPLACEMENT OR REPAIR AT OUR ELECTION FOB POINT OF MANUFACTURE OR AUTHORIZED REPAIR STATION OF SUCH PRODUCTS AND OR PARTS AS PROVEN DEFE...