background image

We have the following matrix to help you quickly identify the most common conditions that exist 

with your Leak Controller™. In the event that you are still having problems with your product 

after consulting this guide, please contact us so we can be of immediate assistance to you. 

∗ 

Please note that whenever the valve closes to the red position (except when testing), 

you 

must do the following

1)  Change the batteries as described in step #1. 

2)  Check and test the sensor and controller  

3)  Look for leaks, it is possible that you had a leak and it has dried  

*

.

'

-

 

The valve in the controller is a ball type with two connection points that have quick-connect 

fittings. The valve is not directionally sensitive so you can insert the incoming water tube and 

the outgoing tube on either side for your convenience.   

 

Follow the diagrams below for correct insertion, locking, and removal procedures. You may 

find it easier to insert the tubing into the controller by removing the controller from the 

mounting plate, if you do, you must remount the controller to the mounting plate when you are 

done.  

 

Once you have correctly inserted the tubing into the controller valve, you can turn your water 

source back on. There should be no leaks at either side of the controller valve, at the water 

source connection, or at the connection to the appliance. 

Check for leaks immediately at all 

locations.

  

 

Generally, if there is a leak it will occur immediately, if this occurs or there is an moisture 

around the valve connections, then close the valve on the water source and repeat steps 3 & 5 

'

! !

/

(

0

'

1

! '

2

2

0

!

3

+

1

4

50

'

0

'

2

2

6

7

2

/

'

'

2
! ! /4

,.87

! ! 5

There are two ways to test the system: 

 

1.  Testing at the Controller (see Step 2). 

2.  Testing at the Sensor.   To test that your 

sensor and controller are working properly, 

insert a coin or screwdriver into the slot on the 

sensor. This replicates a leak condition, and 

the controller should close the valve to the red 

position, sound the alarm, and flash the LED.  

 

To reset the system, hold the button down 

until the LED light stays on, then release the 

button, and reset is confirmed by a single 

beep. Return the valve to the green position. 

   

The controller should be tested 

every month

, at both the controller and sensor(s) to confirm 

the system operation and to exercise the valve. 

'

  ! 9

 

(a) The LED may not be working due to the batteries dying.  Any alarm mode the controller will flash and 

beep until the system is reset or  until the battery dies. 

 

(b)  On LEAK condition, the controller will continually flash and beep 4 times together for 12 minutes or 

until it is silenced/reset by holding the Button when the LED is solid on.  After 12 minutes, the 4 times 

flashing will continue and beeping will be reduced to 4 beeps every 2 minutes to save the battery. 

 

ALWAYS CHECK THE SENSOR(S)  

Condition 

Knob 

Pointing 

LED Light  Speaker 

Sensor  Battery 

Recommended Action 

Normal/

Armed 

Green 

Flashing 

once every 

5 seconds 

Off 

Dry 

Good 

TEST and examine sensor(s) 

when needed (at least monthly) 

TEST

 (15 

Seconds to 

complete) 

Green 

then Red 

Flashing 

4 Flashes  

On 

4 Beeps 

 

Dry 

Good 

Turn the knob to green, the 

controller  will automatically 

reset itself 

LEAK 

Red 

Flashing 

(b) 

On  (b) 

(speaker 

may just 

chirp) 

Wet or 

Dry 

Good  

Examine the Sensor(s),Fix the 

leak, dry sensor(s), change mat, 

hold button until LED light stays 

solid to stop alarm,  turn knob to 

green, change batteries, then 

Test (Step #2)  

Low Battery

 

Maintenance 

Mode #1 

 

Red  

Flashing or 

Off (a) 

2 Flashes 

On or 

Off (a) 

2 Beeps 

Dry 

Bad 

Examine the Sensor(s), hold 

button until LED light stays 

solid to stop alarm,  turn knob to 

green, change batteries, then 

Test (Step #2)  

2 year Shut-

Off 

Maintenance 

Mode #2 

 

Red 

Flashing or 

Off (a) 

2 Flashes 

On or 

Off (a) 

2 Beeps 

Dry 

 

Good 

or Bad 

Examine the Sensor(s), hold 

button until LED light stays 

solid to stop alarm,  turn knob to 

green, change batteries, then 

Test (Step #2)  

*

.

'

:

           ➀                         ➁                         ➂

 

Automatic Operation 

 

Other than the recommended maintenance outlined above, your Leak Controller™ will operate 

automatically. In the event that the sensors detect a leak, the controller will close the valve to 

the red position, and sound an alarm. Please consult either the operations / troubleshooting 

guide for the recommended course of action in the event of a leak, or see step #7.  

 

Low Battery and Auto Shut-Off in Two Years 

 

An additional feature the controller has is a maintenance mode. This can be activated in one of 

two ways. First, if the circuitry detects a low power response from the batteries. In this case the 

system will shut down. and close the valve. 

 

Secondly, the system is programmed to automatically shut itself down every two years. This 

has been incorporated into the controller to cycle the valve in case you live in a very hard 

water environment to exercise the valve. In the event that either of these events takes place, 

please consult the operations/ troubleshooting guide for the recommended course of action. 

 

Manual Valve Close 

 

The controller’s valve can also be shut manually. To do this, push the manual close button 

located on the upper right side of the controller. This will release the latching mechanism and 

close the valve to the red position. To rearm the controller and open the valve, return the Knob 

to the green position. 

 

Fold and place these instructions behind the mounted controller for convenient reference. 

 

*

Internal Ball Valve ¼ turn with safety collar 

   Power output:  6V 

0-150 p.s.i. Pressure rating 

Battery Life:   2 years (normal condition) 

33° - 140°F (1°-60°C) Temperature rating 

Weight:  .90 lbs with batteries 

Dual O-ring quick connect Mur-lok™ Fitting 

 Size:    6.75” (h) x  3.25” (w)  x  2.5” (d) 

Power:  4 x “AA” Alkaline Batteries 

 

➎ 

➎ 

➎ 

➎ 

; &

'

➐ 

➐ 

➐ 

➐ 

<

%

This is a very important part of the installation. The sensor is the heart of the controller, and if  

water doesn’t touch the sensor it will not activate. Also, it is extremely important that the 

metal side of the sensor always remains facing down after the installation.  

 

Once you have confirmed the sensor location, place the sensor mat in that area and then place 

the sensor on top of the mat.  The sensor will work without the mat.  The sensor mat is 

provided only to increase the area where water is drawn to the sensor.  In those areas where it 

is not practical to lay the mat down, just place the sensor on a clean, flat surface. 

 

Ordinary paper towels can be used as 

replacements for the sensor mat. 

 

Every floor or 

seemingly flat surface has 

a slope to it

, and as every location is 

different, care needs to be made at the 

placement of the sensor.  

 

 

To confirm the path of the water in the event of a leak, take a plate or flat pie tin and place it 

near where the sensor will be placed. Pour some water onto the plate and check the direction 

of the flow. Adjust the sensor’s position accordingly to this flow path to make sure in the 

event of the leak the water flows towards the sensor. 

 

Additional sensors may be added to your system and may be purchased through our website. 

To connect a second sensor, push the connectors at the end of the second sensor cable onto the 

metal connectors located under the first sensor.  Route the separate wires around the bottom 

part of the sensor and out the other end of the sensor.  

 

To confirm that the second sensor is working properly, insert a coin or screwdriver into the 

sensor slots, this should replicate a leak and activate the alarm feature on the controller. To 

reset the controller, see Step 7. 

 

* Please note that for the sensors to work, the leak does not have to enter the slots on top of 

the sensors. This may happen, but the sensors also detect surface moisture via the sensor 

probes on the bottom of the sensor. 

➏ 

➏ 

➏ 

➏ 

=

Controller Maintenance 

  

Replace all four batteries with “AA” Alkaline type batteries: 

  

a)  Annually (every year) 

b)  If the alarm has been sounding for a undetermined length of time 

c)  If the low battery alarm chip is sounding  (2 flash and 2 beep) 

d)  If the valve does not close during test 

 

 

Since the controller is in constant contact with your water supply, 

the maximum life 

expectancy of the controller is five years. 

Although you may achieve longer use of the 

controller depending on the quality of your water source, we recommend that do not exceed 

this time period. 

  

Sensor Maintenance 

  

Every month when testing the operation of the controller, examine each sensor to confirm that 

it is laying metal side down on the sensor mat, and wipe the bottom of the sensor metal strips 

with a clean dry cloth.  

Locate a clean, flat wall surface that is close and parallel to, the water source to which you will 

be connecting. Make sure there is at least a 3” clearance from 

the top of the controller to leave room to change the batteries in 

the future. Find a wall stud (if possible); align the mounting 

plate on the wall with the single tab arm pointing up, and the 

tabs of the plate facing outwards away from the wall.  

 

Drill a hole using the mounting plate as a guide, and drive the 

two #8 screws into the mounting plates holes and into the wall. 

Use wall anchors or toggle bolts if the wall is hollow. Attach 

the top tab receptacle on the controller to the top tab on the 

mounting plate, and then insert the two bottom receptacles on 

the controller to the two bottom tabs on the mounting plate and 

pull down. 

 

• 

The controller should be flush against the wall, resist 

movement, and be able to be connected to your piping. 

❹ 

❹ 

❹ 

❹ 

8