WB Mfg iXchange SSW1202-AL Скачать руководство пользователя страница 15

wibenchmfg.com

507 E. Grant St. Thorp, WI 54771 • P - 800.242.2303

Specifications are subject to change. Product 

images are for illustrative purposes only and may 

differ from the actual product.

15

iXchange® Wall

Assembly Instructions

SSW1202-AL

Care & Maintenance

Storage Cabinet Surfaces

Daily Care and Cleaning for Laminate Surfaces

The laminate surface may be cleaned with warm water and 

mild soaps, such as those used for hands or dishes.  Heavy 

solvents can affect edging adhesion.
Note, that while there are different grades and chemical 

resistance properties to various types and manufacturers of 

plastic laminate, the cleaning recommendations are universal.
To clean the surface, use a damp cloth or sponge and a mild 

soap or detergent. Difficult stains such as coffee or tea can 

be removed using a mild household cleaner and baking soda; 

mixing to achieve a paste consistency. Use a stiff nylon bristle 

brush, scrubbing (approx. 15-20 strokes) the affected area. Do 

not scrub so as to damage or scratch the surface finish. Doing 

so will void the warranty.
Stubborn stains that resist any of the above cleaning methods 

may require the use of undiluted household bleach or nail 

polish remover. Use a cotton ball saturated with bleach or nail 

polish remover (acetone); gently rub the stain for up to two 

minutes. Rinse thoroughly with warm water and wipe dry using 

a soft cloth. This step may be repeated if the stain appears to 

be going away and the color of the laminate has not 

been affected.

WARNING: 

Prolonged exposure of the laminate surface to 

bleach will cause discoloration. Always rinse laminate surfaces 

after cleaning! Failure to rinse after cleaning can cause 

damage; even if a small amount of cleaning solution remains 

on the surface. A dry residue may be invisible; however, 

moisture from cups or drinks can reactivate it, and result in 

permanently etched scars or stains over time.

Recommended Household Cleaners:

•  Clorox® (Prolonged exposure can mar the surface)
•  Formula 409®
• Dawn®
•  Glass Plus®
•  Dow Bathroom Cleaner with Scrubbing Bubbles™
• Fantastik®
• Favor®
• Windex
• Lestoil®
• Pledge®

•  Grease Relief®
•  Mr. Clean®
•  Lysol® Brand Disinfectant Basin/Tub/Tile Cleaner
•  TOP JOB®

A Few Notes of Caution:

Acidic or abrasive cleaners can damage laminate surfaces; do 

not use them.  Drain cleaners containing lye will permanently 

damage the laminate surface. If you spill a drain cleaner, wipe 

it up immediately and rinse several times with water.
Hair, textile and food dyes can cause permanent stains. If 

dye should happen to spill, wipe it up immediately with dish 

washing detergent or an all-purpose cleaner.
•  Wipe spills away promptly and rinse several times with water.
•  Rust removers contain harsh chemicals, which will quickly 

cause permanent damage. If a spill occurs, wipe off residue 

immediately and wash thoroughly with soapy water and rinse  

several times.
•  Steel wool and other abrasive pads will damage the laminate 

face. Do not use them for cleaning and don’t store steel wool 

pads on your counter top; the metal can rust and leave stains.
•  Toilet bowl cleaners contain harsh chemicals that can cause 

permanent damage.
•  If spills occur, wipe up immediately, wash surface with soapy 

water and rinse several times.
•  Sharp objects can damage the surface; marring its beauty 

and lowering wear and stain resistance. Although high 

pressure laminates are somewhat resistant to scratch and 

marring, the surface can be damaged, even under normal use.
•  Laminate surfaces may need occasional dusting depending 

on where it’s used.
•  To keep the surface beautiful, use a non-oily furniture 

spray. Furniture polish can also help hide fine scratches in the 

surface.
•  Excessive contact with moisture, high humidity and other 

harsh environmental conditions may not affect the laminate 

surface itself, but may cause the laminate surface to pull away 

from the core material it is adhered to, causing failure.
•  Although not a material failure, this is considered a product 

failure and may void the product warranty.
The cleaners listed below can cause damage to the surface of 

laminate:

Chemical Ingredient Synonymous Names

Hydrochloric Acid

Muriatic Acid, Hydrogen Chloride

Sulfuric Acid

Oleic Acid, Oil of Vitriol, Oleum

Hydrofluoric Acid

Rust Remover

Phosphoric Acid

Rust Remover

Sodium Hydroxide

Caustic Soda, Caustic Lye, Soda Lye

Содержание iXchange SSW1202-AL

Страница 1: ...Allen wrench OR 4mm 5mm hex bit 2 Phillips screwdriver NOTE The cabinets with the same model numbers are interchangeable and can be used in any location where that model number is needed Step 1 Slide base cabinets together in the order as shown below and level in place With cabinets aligned together place the 1 4 20x30mm joint connector bolt w Loctite through pre drilled hole on the inside of one ...

Страница 2: ...Assembly Instructions SSW1202 AL iXB3112 2 iXB2400 2 Step 2 Place and center the LEFT base top iXLBTop 71 4 on the farthest LEFT base cabinets iXB2400 2 iXB3112 2 Align the threaded inserts in the bottom of the base top with the pre drilled holes in the sub tops of the base cabinets Use 20x30mm joint connector bolts w Loctite to fasten the base top to the base cabinets as shown below JCB iXLBTop 7...

Страница 3: ...ssembly Instructions SSW1202 AL Step 3 Place and center the RIGHT base top iXRBTop 71 4 on the farthest RIGHT base cabinets iXB3112 2 iXB2400 2 Align the threaded inserts in the bottom of the base top with the pre drilled holes in the sub tops of the base cabinets Use 20x30mm joint connector bolts w Loctite to fasten the base top to the base cabinets as shown below iXB3112 2 iXB2400 2 iXRBTop 71 4...

Страница 4: ...ctions SSW1202 AL iXW1155 3 JCB Step 4 Locate wall cabinet iXW1155 3 Place it on the LEFT side of base top iXLBTop 71 4 aligning the pre drilled holes in the bottom of the wall cabinet with threaded inserts in the base top Bolt into place using 20x30mm joint connector bolts NOTE The cabinets with the same model numbers are interchangeable and can be used in any location where that model number is ...

Страница 5: ...using 20x30mm joint connector bolts Step 6 With pre drilled holes in wall cabinets aligned together place the 1 4 20x30mm joint connector bolt w Loctite through pre drilled hole on the inside of one of the cabinets making sure bolt is pushed as far as it can go While holding the joint connector bolt flush to the cabinet take a 1 4 20x17mm joint connector nut and attach it to the end of the bolt th...

Страница 6: ...RBTop 71 4 using 20x30mm joint connector bolts Step 8 With pre drilled holes in wall cabinets aligned together place the 1 4 20x30mm joint connector bolt w Loctite through pre drilled hole on the inside of one of the cabinets making sure bolt is pushed as far as it can go While holding the joint connector bolt flush to the cabinet take a 1 4 20x17mm joint connector nut and attach it to the end of ...

Страница 7: ...y differ from the actual product 7 iXchange Wall Assembly Instructions SSW1202 AL iXFEL JCB Step 9 Located finished wall panel iXFEL Align the threaded inserts in the panel to the pre drilled holes in cabinets iXW1155 3 and iXB2400 2 on the LEFT side of the iXchange Wall Bolt wall panel to cabinets using 20x30mm joint connector bolts iXW1155 3 iXB2400 2 ...

Страница 8: ... product 8 iXchange Wall Assembly Instructions SSW1202 AL iXLWTop_72 JCB Step 10 Locate LEFT wall top iXLWTop_72 and place on top of upper wall cabinets iXW1155 3 iXW1155 3 with the threaded inserts facing down Align the threaded inserts with the pre drilled holes in the sub tops of both wall cabinets and bolt into place using 20x30mm joint connector bolts iXW1155 3 iXW1155 3 ...

Страница 9: ... product 9 iXchange Wall Assembly Instructions SSW1202 AL Step 11 Locate RIGHT wall top iXRWTop_72 and place on top of upper wall cabinets iXW1155 3 iXW1155 3 with the threaded inserts facing down Align the threaded inserts with the pre drilled holes in the sub tops of both wall cabinets and bolt into place using 20x30mm joint connector bolts iXLWTop_72 JCB iXW1155 3 iXW1155 3 ...

Страница 10: ...the channel on the front of the upper track Cut to fit Step 13 There will be a double top track with 2 Forbo insert and a double bottom track with blade tray Both tracks will be pre drilled The cabinets will not have any pre drilling Align the front edge of the double bottom track to the front edge of the base tops iXLWTop_72 iXRWTop_72 Mount using 5 8 8 truss head screws Attach double track with ...

Страница 11: ...nd tighten jamb nut against carrier Slide whiteboard panels onto the track from the open end Use the front two channels if only using 2 boards There will only be one panel per track Step 15 Slide map hooks clips and roller brackets on from open end Step 16 Attach right side panel iXFER to wall cabinet iXW1155 3 and base cabinet iXB2400 2 using 20x30mm joint connector bolts Pre drilled holes in the...

Страница 12: ... illustrative purposes only and may differ from the actual product 12 iXchange Wall Assembly Instructions SSW1202 AL Step 17 Attach bumpers to the end panels near lower track using 5 8 8 truss head screws Holes in bumpers will line up with pre drilled holes in the end panels Finished assembly of iXchange Wall SSW1202 AL ...

Страница 13: ...Joint connector bolt 20x30mm Joint connector nut 20x17mm 2 4 each 4 each iXW1155 3 0400236 0404229 Open wall cabinet with 1 vertical divider and 6 adj shelves Joint connector bolt 20x30mm Joint connector nut 20x17mm 3 4 each 4 each iXFEL 0400236 iXchange wall left side panel Joint connector bolt 20x30mm 1 8 iXFER 0400236 iXchange wall right side panel Joint connector bolt 20x30mm 1 8 iXLBTop 71 4 ...

Страница 14: ... actual product 14 iXchange Wall Assembly Instructions SSW1202 AL Part Description Qty 0400684 118 3 Track Upper w Fascia 2 Map Rail 1 0400685 118 3 Track Lower w Marker Tray 1 0400695 Hardware pack for iXchange Wall Carriers 4 Bumpers and screws N A End stops and screws 2 Map hooks 7 Roller brackets 2 Flat Head screws 18 Truss Head screws 25 0400686 4 x5 White Board 2 ...

Страница 15: ...Fantastik Favor Windex Lestoil Pledge Grease Relief Mr Clean Lysol Brand Disinfectant Basin Tub Tile Cleaner TOP JOB A Few Notes of Caution Acidic or abrasive cleaners can damage laminate surfaces do not use them Drain cleaners containing lye will permanently damage the laminate surface If you spill a drain cleaner wipe it up immediately and rinse several times with water Hair textile and food dye...

Страница 16: ...loth with isopropyl alcohol Begin cleaning in a circular motion to loosen marker residue Dry with a clean dry cloth If isopropyl alcohol is not available try writing over the permanent ink marker with a dry erase marker then wipe with a clean dry cloth Repeat as often as necessary to remove all residues Cabinet Hardware Door and Drawer Pulls Handles Pulls Handles can easily be cleaned with a damp ...

Отзывы: