INSTRUCTIONS DE DÉMARRAGE RAPIDE

 

WSM3300

Pour des renseignements sur les pièces, les produits et l’entretien,  

visiter 

www.waynepumps.com

Système de notification 

préalable de 12 volts

MODE D’EMPLOI ET LISTE DES PIÈCES 

DÉTACHÉES

© 2012, WAYNE/Scott Fetzer Company.

ÉTAPE 1 : VÉRIFICATION DU CONTENU DE L’EMBALLAGE

ÉTAPE 3 - INSTALLER LA POMPE DE SECOURS ET 
L’INTERRUPTEUR À FLOTTEUR

ÉTAPE 4 - INSTALLER LA BATTERIE

ÉTAPE 6 - BRANCHER LES FILS

ÉTAPE 7 - POSITIONNER LA BATTERIE ET LE CONTRÔLEUR

Select Language

English   Español Français  

ÉTAPE 8 - CONFIGURATION DU CONTRÔLEUR

Batteries adaptées

Transformateur

MISE EN GARDE Porter 

des lunettes de sécurité 

au moment de brancher la 

batterie

ÉTAPE 5 - BRANCHER LE COUVERCLE À LA BATTERIE

Transformateur (1) 

Assemblage couvercle et contrôleur (1)  

Boîte de batterie (1)  

Pompe de secours de 12 volts c.c. (1) 

Interrupteur avec pince (1) 

Last Auto Test: --/--/--

MENU   MUTE   RESET

12.1 V

System Armed & Ready

100%

Sélectionner la langue de départ et suivre les instructions à 

l’écran pour configurer le contrôleur. Une fois la configuration 

du contrôleur terminée, rétablir l’alimentation c.a. et vérifier la 

pompe principale conformément à la description donnée dans 

la section Fonctionnement de ce manuel.  

Rouge

Noir

N’inclut pas : 
la batterie à décharge 

poussée de 12 

volts c.c., la prise 

téléphonique, la ligne 

téléphonique, le 

tuyau et les raccords 

nécessaires.

Affichage principal

Affichage au démarrage

Interrupteur 

à flotteur

Sécurité

Pompe c.c.

Requiert un service de ligne terrestre téléphonique actif

ÉTAPE 2 - METTRE HORS TENSION

      

      Si la source de courant 

n’est pas visible, verrouiller en 

position ouverte (arrêt) et étiqueter 

pour éviter tout rétablissement 

inattendu de l’électricité. Le non-

respect de cette directive POURRAIT 

entraîner une décharge électrique 

mortelle !

Tuile de 

drainage

Téléphone 

12

3

6

9

Le temps de charge 

minimum avant utilisation 

est de 24 heures

LIRE, S’ASSURER DE COMPRENDRE ET SUIVRE TOUTES LES INSTRUCTIONS DE CE MANUEL - NE PAS JETER.  

Le non-respect de ces instructions pourrait entraîner des dommages matériels, des blessures corporelles ou la mort.

WAYNE - WSB1275 

WAYNE - WSB1240 

ou

Batterie marine à décharge poussée 

de 12 volts 

Batterie au plomb-acide scellée de 

12 volts 

Batterie à décharge poussée de 12 

volts 

Batterie à cellule humide de 12 volts

Capacité = 40 Ah minimum 

Содержание WSM3300

Страница 1: ...able Batteries Transformer Wear safety glasses when connecting the battery STEP 5 CONNECT LID TO BATTERY Transformer 1 Lid and Controller Assembly 1 Battery box 1 12 Volt DC back up pump 1 Switch with...

Страница 2: ...to equipment GENERAL SAFETY INFORMATION This pump is NOT rated for use with flammable combustible liquids vapors or dusts Do NOT use to pump flammable combustible liquids vapors or dusts Do NOT use i...

Страница 3: ...separately to the top of the discharge pipe This will allow the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of...

Страница 4: ...pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10...

Страница 5: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Страница 6: ...d phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up sys...

Страница 7: ...up 3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or...

Страница 8: ...E NUMBER REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an in...

Страница 9: ...efective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make s...

Страница 10: ...R PUR POSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Som...

Страница 11: ...l set to 4 rings the System set to 5 rings 1 Make a phone call to the System phone number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the Syste...

Страница 12: ...tr leur termin e r tablir l alimentation c a et v rifier la pompe principale conform ment la description donn e dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie d charge...

Отзывы: