8

TROUBLE SHOOTING CHART

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or run

1.  Blown fuse or breaker

1.  Check pump housing or power cord 

for damage, before replacing fuse or 
resetting breaker. If in doubt call an 
electrician

2.  Low supply voltage

2.  Contact an electrician

3. Worn motor

3. Replace pump

4.  Impeller not rotating (jammed)

4.  If impeller will not turn, disconntect 

pump from power source and remove 
blockage (see Volute and Impeller 
Cleaning Instructions)

5.  Thermal protector open

5a. Water temperature is too high, allow   

water to cool before pumping

  b. Inlet clogged, remove debris
  c. Motor seized, replace pump
  d. Discharge clogged or hose kinked/

clogged. Clear blockage

Pump starts but delivers little or no 
fl ow

1.  Inlet clogged

1.  Clean debris from exterior of volute 

and all debris fi ltering features

2.  Low supply voltage

2.  Contact an electrician

3.  Restriciton in discharge hose

4.  Discharge lift too high

3.  Unwind garden ose, remove any 

kinks or restrictions in hose

4.  Water level to end of garden hose is 

25 ft. or greater, reduce vertical lift.

5.  Impeller clogged

5.  Disconnect pump from power source 

and remove blockage(see Volute and 
Impeller Cleaning Instructions)

LIMITED WARRANTY

For one year for WWB 2 model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, 
any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship. 
Please call Wayne Water Systems (866-928-7284) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this 
warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. 

This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, 
or failure to operate in accordance with Wayne Water Systems’ written instructions.

THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM 
COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE 
AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH 
THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT 
(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES. 

You 

MUST

 retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you 

MUST

 send a 

copy

 of the purchase receipt along 

with the material or correspondence. Please call Wayne Water Systems (866-928-7284) for return authorization and instructions.

DO NOT MAIL THIS FORM TO Wayne Water Systems.

 Use this form only to maintain your records.

MODEL NO._____________________  SERIAL NO._________________________ INSTALLATION DATE __________________________

ATTACH YOUR RECEIPT HERE

QUICK START INSTRUCTIONS

WWB 2

For product & service information

visit www.waynepumps.com

READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE INSTRUCTIONS AND SAFETY PRECAUTIONS  
IN THIS MANUAL CAN RESULT IN SERIOUS INJURY OR DEATH. KEEP THIS MANUAL FOR FUTURE REFERENCE.

© 2018, WAYNE/Scott Fetzer Company.

STEP 3 - REMOVE DISCHARGE CAP

STEP 4 - ATTACH GARDEN HOSE TO BRASS DISCHARGE

STEP 5 - PLACE IN WATER

STEP 6 - ALWAYS PLUG INTO GFCI OUTLET. UNPLUG PUMP 
WHEN WATER IS NO LONGER BEING MOVED. DO NOT RUN 
PUMP DRY FOR EXTENDED PERIOD OF TIME.

FOR FURTHER INSTRUCTIONS, DOWNLOAD OWNER’s 
MANUAL ONLINE

www.waynepumps.com/product/wwb

STEP 1 - GET TO KNOW YOUR PUMP

• 10 FT. POWER CORD

• TOP DISCHARGE

• SIDE DISCHARGE

• CORD WRAP

• CORD CLIP

• HANG LOOP

STEP 2 - CHOOSE THE DISCHARGE BEST FOR THE 
APPLICATION 

• TOP DISCHARGE 

is perfect for water

removal in tight spaces:  

Laundry Tubs, 

Window Wells, Buckets, etc.

• SIDE DISCHARGE 

is ideal for easy

water removal from  at open surfaces:

  

Flat Roofs, Flooded Basements, standing 
water in yard, crawl spaces, etc.

• WARNING DECAL

Removes water down to  

1/16 in. of surface,

VIRTUALLY DRY!

 

TWIST

TIP: Unwind and remove all kinks 
and bends in hose for more ef cient 
pumping and priming.

Requires 3/16 in. of water  

to start pumping.

620011-001 B 08/18

• 

• 

CARRYING HANDLE

• 

• 

-OR- 

-OR- 

®

Отзывы: