background image

Operating Instructions and Parts Manual

5

MAINTENANCE

  Always disconnect power source before 

attempting to install, service, or maintain the pump.

  Toujours débrancher le cordon d'alimentation 

avant d'essayer d'installer, de réparer ou de faire l'entretien de la 

pompe.

IMPELLER REPLACEMENT

NOTE: 

These parts are designed to handle most clear, nonflammable 

liquids with slight amounts of abrasives. When impeller vanes become 
worn from use, or damaged due to pumping abrasive liquids or trash, 
pump performance will be reduced or prevented altogether and will void 
warranty.
1.  Remove the four cover plate screws holding motor housing and 

pump housing together. Cover plate is now free and can be 
removed. 

2.  Inspect gasket and impeller for wear and damage. If there is any 

evidence of wear or damage, replace the part(s). 

3.  Lubricate new impeller with vegetable oil and reinstall by aligning flat 

on impeller hub with flat on motor shaft. 

4.  Reassemble gasket, cover plate, and cover plate screws.

SHAFT SEAL REPLACEMENT

Motor shafts are sealed with factory pre-lubricated lip-type seals which 
are good for the life of the pump. If the seal leaks, it is usually because 
the pump has handled abrasive liquids. If the motor shaft is scored (deep 
grooves), the complete pump must be replaced. 
1.   Remove and inspect impeller parts as specified in the impeller 

replacement instructions. Replace worn parts. 

2.   Remove two pump body mounting screws and slide pump body 

from motor. Pry out seal retaining ring and push worn shaft seal 
from inside of pump body. 

3.   Lubricate new seal with lightweight vegetable oil, push it into pump 

body with lip facing away from motor, and push in seal retaining ring. 

4.   Reassemble pump body onto motor with mounting screws. Follow 

steps 3 and 4 in Impeller Replacement.

NOTES

Содержание PC1 Series

Страница 1: ...d Bronze Hose Fittings Self Priming Transfer Pump www waynepumps com PERFORMANCE Model Volt Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft 25 ft PC1 12 Gal hr 310 300 265 230 185 145 Please read and save...

Страница 2: ...r water from one point to another in a temporary application This Transfer Pump is convenient when normal power is not readily available Typical applications include removing water from pool covers cl...

Страница 3: ...nnulera la garantie et rendra la pompe inutilisable 2 Use a strainer when pumping from a creek pond or source where foreign objects may be sucked into the pump The strainer should prevent solids from...

Страница 4: ...es lire et suivre les instructions dans tous les manuels d instruction Pour r duire le risque d explosion de batterie suivez les instructions dans ce manuel et celles publi es par le fabricant de la b...

Страница 5: ...ge replace the part s 3 Lubricate new impeller with vegetable oil and reinstall by aligning flat on impeller hub with flat on motor shaft 4 Reassemble gasket cover plate and cover plate screws SHAFT S...

Страница 6: ...charges on Products or parts submitted for repair or replacement must be paid by purchaser This Limited Warranty is not transferrable This Limited Warranty does not cover Products which have been dama...

Страница 7: ...er as shown in parts list Address parts correspondence to WAYNE Water Systems 101 Production Drive Harrison OH 45030 U S A Figure 2 Replacement Parts Illustration for Self Priming Transfer Pumps BATTE...

Страница 8: ...8 NOTES...

Отзывы: