Wayne P250AF Скачать руководство пользователя страница 25

24

MSR & MSR-DC  22019-003 Rev. C  08/15/00

LIMITED WARRANTIES FOR OIL AND 

GAS BURNERS, MADE BY WAYNE AND

USED IN RESIDENTIAL INSTALLATIONS

WAYNE COMBUSTION SYSTEMS (“WAYNE”) warrants to those who purchase its Oil Burner Models for resale or
for incorporation into a product of resale, that its burner is free from defects in material and workmanship under normal
use and service for thirty-six (36) months from the date of manufacture. ALL GAS BURNERS manufactured by
“WAYNE”  will be similarly warranted for eighteen(18) months from date of manufacture except where original
manufacture offers a greater warranty. (Reference #6 below) THESE LIMITED WARRANTIES DO NOT APPLY
UNLESS THE BURNER COVERED BY IT IS PROPERLY INSTALLED BY A QUALIFIED, COMPETENT
TECHNICIAN
, WHO IS LICENSED WHERE STATE AND/OR LOCAL CODES PREVAIL, AND WHO IS
EXPERIENCED IN MAKING SUCH INSTALLATIONS
, IN ACCORDANCE WITH NFPA #31 OF THE NATIONAL FIRE
PROTECTION ASSOCIATION AND IN ACCORDANCE WITH ALL LOCAL, STATE AND NATIONAL CODES.

Any  IN-WARRANTY burner component which is defective in material or workmanship will be either repaired or
replaced as follows:

1.

Fuel units, motors, transformers, gas valves, and controls should be returned to an authorized service station or
distributor of WAYNE for determination of applicability of this LIMITED WARRANTY as to either repair or
replacement, where said service station or distributor is reasonably available in the customer’s locality.  The
manufacturers of burner components regularly publish and distribute listings showing the locations of their network
of service stations. Where such local service is NOT available for the burner components described above or other
burner parts are involved, these items should be returned, freight prepaid, to WAYNE Service Department, 801
Glasgow Ave, Fort Wayne, Indiana 46803.

2.

Burners and/or component(s) determined to be covered under this LIMITED WARRANTY by WAYNE shall be
repaired or replaced at WAYNE’s sole option.

3.

WAYNE is not responsible for any labor cost for the removal and replacement of said burner or burner components
and equipment associated therewith.

4.

A burner so repaired will then carry the LIMITED WARRANTY equal to the unexpired portion of the original
burner LIMITED WARRANTY.

5.

If inspection by WAYNE does NOT disclose any defect covered by this LIMITED WARRANTY, the burner or
burner component(s) will be either repaired or replaced at the expense of the customer and WAYNE’s regular
charges will apply.

6.

If the original manufacturer of a burner component offers a warranty greater than either of our LIMITED
WARRANTIES described above, then this portion will be added to our LIMITED WARRANTY.

This LIMITED WARRANTY does NOT cover products which have been damaged as the result of accident, abuse,
misuse, neglect, improper installations, improper maintenance or failure to operate in accordance with WAYNE’s
written instructions.

These LIMITED WARRANTIES do not extend to anyone except the first purchaser at retail and only when the burner
is in the original installation site.

IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE
LIMITED TO THE DURATION OF THE LIMITED EXPRESS WARRANTIES CONTAINED HEREIN. WAYNE
EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES
OF ANY NATURE FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY.

Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
Also, some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.  WAYNE neither assumes or authorizes any person to assume for WAYNE
any other liability or obligation in connection with the sale of these products. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.

WAYNE COMBUSTION SYSTEMS

801 GLASGOW AVE.

FORT WAYNE, IN 48803

Содержание P250AF

Страница 1: ...T TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow th...

Страница 2: ...been heated adequately without wide variations in temperature without objectionable drafts and without excessive fuel costs in the past If the heating system is deficient with respect to any of the ab...

Страница 3: ...ny other condition which might make the unit unsatisfactory for gas conversion is found proper arrangements should be made for replacement or repair before proceeding with the burner installation Crac...

Страница 4: ...IGURE 4 1 2 12 7 mm Minimum rise 1 4 6 35 mm to the foot 305 m Minimum rise 1 4 6 35 mm to the foot 305 m Minimum rise 1 4 6 35 mm to the foot 305 m 90 1 57 rad ANGLE TYPE DRAFT HOOD Always install in...

Страница 5: ...52 4mm 180 000 52 75 250 000 73 27 7 inch 177 8mm NOTE If the flue pipe exceeds 10 ft 3 048m in length or contains more than two elbows use next size larger pipe and draft hood NO MOVEABLE FLUE PIPE D...

Страница 6: ...ATION OF BURNER AND CONTROLS The inshot power gas burner was designed especially for converting gun fired oil designed furnaces and boilers Due consideration was given to making it as simple and easy...

Страница 7: ...1 64 41290 8 203 2 X 8 203 2 plus back up of plus 1 1 2 38 1mm 120 000 35 17 72 1 4 46610 8 1 2 215 9 x 1 2 215 9 1 1 2 38 1mm asbestos or magnesia 140 000 41 03 81 52260 9 228 6 x 9 228 6 or more loo...

Страница 8: ...ping must comply with local codes and ordinances or the National Fuel Gas Code ANSI Z223 1 1984 and NFPA No 54 A sediment trap or drip leg must be installed in the supply line to the burner A union sh...

Страница 9: ...SIZE LENGTH LENGTH OF THREAD OF THREAD 3 8 9 525 3 8 9 525 9 16 14 29 1 2 12 7 1 2 12 7 3 4 19 05 3 4 19 05 1 2 9 16 14 29 13 16 20 64 1 25 4 9 16 14 29 1 25 4 PIPE CAPACITY TABLE Nominal Diameter of...

Страница 10: ...rator until it snaps Repeat this until the pilot lights Note this may take some time until all the air is bled out of the line 7 Hold the red button on the valve for seconds then release 8 Observe pil...

Страница 11: ...10 P265DI JUNCTION BOX ROTATED P265DI...

Страница 12: ...O even if CO2 and O2 are within acceptable limits The flue gas sample is taken through the same hole used for the CO2 test CO test instrument must be used for this test The most common causes of CO ar...

Страница 13: ...mmable vapors and liquids The flow of combustion and ventilating air to the burner must not be blocked or obstructed in any manner CLEANING OF BURNERS Remove the burner from the appliance and visually...

Страница 14: ...the flame current also holds the safety lockout timer in the reset or normal operating condition SAFETY LOCKOUT TIME S8600 only The safety lockout timer circuit starts timing the moment the trial for...

Страница 15: ...3 PILOT BURNER OPERATION Pilot burner lights Module senses flame current OR Pilot burner does not light Module Response S8600A F Ignition spark continues pilot valve remains S8610A F open until system...

Страница 16: ...that pilot flame covers flame rod and is steady and blue Adjust pilot flame If problem persists replace the module NOTE If S8600B H S8610B H goes into lockout reset system For S8600M wait 6 min norm...

Страница 17: ...N On a call for heat voltage is applied to the ignitor across Terminals 1 power and ground of the input connector A high voltage spark is then generated from the spark electrode to ground Simultaneous...

Страница 18: ...replace high voltage wire e Check that the high voltage lead wire is not too close to a metal surface to insure that arcing will not occur at any point other than across the H V electrode Also insure...

Страница 19: ...ignitor should be relocated to an area that is within this temperature range 8 Relative Humidity The 05 16 is coated for moisture resistance to 90 percent relative humidity Caution should be taken to...

Страница 20: ...le Part 61770 002 1 Motor relay 60187 1 Transformer 120 24V 60186 003 1 Bulkhead Union 61455 1 Thermocouple 5 127mm Burner 60154 1 Thermocouple 8 203 2mm Burner 60987 1 Thermocouple 11 279 4mm Burner...

Страница 21: ...L P Gas Pg 15 1 Pilot Orifice Natural Gas 024 610mm 60680 002 1 Pilot Orifice L P Gas 018 457mm 60680 1 Thermocouple 60987 1 Flame Spreader Assembly 61818 1 Piezo Ignitor 63213 001 1 Gas Valve Standin...

Страница 22: ...ct Spark DI 1 62898 001 Orifice Holder 5 127mm Units 1 60249 Orifice Holder 8 203 2mm Units 1 60250 Orifice Holder 11 279 4mm Units 1 See Chart Orifices Natural gas 1 See Chart Orifices LP gas 1 61455...

Страница 23: ...1 See Chart Orifices Natural gas 1 See Chart Orifices LP gas 1 60680 002 Pilot Orifice Natural gas 1 60680 Pilot Orifice LP gas 1 60987 Thermocouple 1 61818 Flamespreader 1 63213 001 Piezo Spark Gener...

Страница 24: ...23 Notes...

Страница 25: ...his LIMITED WARRANTY by WAYNE shall be repaired or replaced at WAYNE s sole option 3 WAYNE is not responsible for any labor cost for the removal and replacement of said burner or burner components and...

Отзывы: