WAYNE COMBUSTION SYSTEMS
801 GLASGOW AVE.
FORT WAYNE, IN 46803
ELECTRIC SHOCK HAZARD
OVERHEATING HAZARD
HIGH VOLTAGES ARE PRESENT IN THIS EQUIPMENT.
FOLLOW THESE RULES TO AVOID ELECTRIC SHOCK.
Use only a properly grounded circuit. A ground fault
interrupter is recommended.
Do not spray water directly on burner.
Turn off power before servicing.
Read the owner’s manual before using.
SHOULD OVERHEATING OCCUR:
Shut off the manual gas valve to the appliance.
Do not shut off the control switch to the pump or blower.
SPECIFICATIONS
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. OPEN WINDOWS
2. DON’T TOUCH ELECTRICAL SWITCHES
3. EXTINGUISH ANY OPEN FLAME
4. IMMEDIATELY CALL YOUR GAS
SUPPLIER.
THESE INSTRUCTIONS SHOULD BE AFFIXED TO THE
BURNER OR ADJACENT TO THE HEATING APPLIANCE.
MODELS
P250AF
P265
P250AF-EP
P265F
P250AF-DI
P265-EP
P265-EP
GAS BURNER
Publication Date 5/01 - Revision B - Manual 101220
NOTE: Dimensions in ( ) are informational only. English values take priority.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or death.
-
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
-
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
-
Installation and service must be performed by a qualified
installer, service agency or the gas supplier. Warranty is
voided if not installed by qualified service person.
CARBON MONOXIDE IS A COLORLESS, ODORLESS GAS
THAT CAN KILL. FOLLOW THESE RULES TO CONTROL
CARBON MONOXIDE.
Do not use this burner if in an unvented, enclosed area. Carbon
monoxide may accumulate.
Do not adjust the pressure regulator. High pressures produce
carbon monoxide.
Check flue gases for carbon monoxide. This check requires
specialized equipment.
Allow only qualified burner service persons to adjust the burner.
Special instruments and training are required.
Read the owner’s manual before using.
CARBON MONOXIDE
POISONING HAZARD
NOTICE
BURNER MODELS
MINIMUM INPUT
MAXIMUM INPUT
FUELS
P-250AF & P-250AF-EP & P250AF-DI
50,000 BTU/HR (14.65 kW/Hr)
250,000 BTU/Hr (73.27 kW/Hr)
Natural & L.P. Gas
P-265 & P-265-EP
65,000 BTU/HR (19.05 kW/Hr)
200,000 BTU/Hr (58.61 kW/Hr)
Natural & L.P. Gas
P-265-F & P-265F-EP
65,000 BTU/HR (19.05 kW/Hr)
200,000 BTU/Hr (58.61 kW/Hr)
Natural & L.P. Gas
ELECTRICAL
Power Supply - 115V/60HZ 1 Ph.
MOUNTING:
Adjustable Flange is Standard
Pedestal Mount is Optional.
Содержание P250AF
Страница 11: ...10 P265DI JUNCTION BOX ROTATED P265DI...
Страница 24: ...23 Notes...