background image

INSTALLATION MANUAL

5

6.  Install discharge plumbing according to local, regional and 

state codes. Rigid PVC pipe is required. Do not use flex 
hosing in a permanent application. 

7.  Install a check valve (required) to prevent back-flow. The 

Wayne check valve (62061-WYN1) may be positioned just 
above the basin to allow easy removal of the pump for 
cleaning and service.

8.   Install a gate valve or ball valve if required by local, regional 

or state code.

9.  Secure power supply cord to discharge pipe using cable or 

zip ties to prevent possible switch entanglement. 

10.  Connect pump power supply cord to a ground fault circuit 

interrupter (GFCI) receptacle.

11.  Fill the basin/pit with water. The pump will start when the 

water level has reached the switch-on level.

12.  The pump will stop when the water level has reached the 

switch-off level.

13.  Verify the switch is operating without any obstruction from 

the pump, piping and basin.

14.  Fill the basin/pit with water again. While the pump is 

draining the basin/pit, verify the discharge pipe is carrying 
the water to a point at least 3 ft. away from the foundation.  
If the discharge line is exposed to freezing temperatures, 
the pipe must be positioned in a downward slope away 
from the foundation so any remaining water will drain away 
and not freeze.

15.  Secure the basin cover and gasket to the basin to prevent 

debris from falling into the basin, prevent personal injury, 
and to contain gases and/or odors.

TYPICAL SUMP INSTALLATION

1.  This installation must be in accordance with the National 

Electric Code and all applicable local codes and 
ordinances.

2.  Use a basin (purchased separately) or pit that is large enough 

to accommodate the pump. 

3.  Clean the basin/pit of all debris.

4.  If using a basin, place the pump directly on the bottom of 

the basin. To prevent damage set the pump on a solid, level 
surface.  Do not place pump directly on clay, earth, gravel or 
sand.  A brick or block must be installed under the pump to 
provide a solid base.

5.  Position pump so the switch is away from the inlet so 

switch is clear from incoming water. Verify the switch has 
at least 1 in. clearance to the side wall of the basin and is 
free to move throughout its movement. If optional control 
device or float is used, follow mounting instruction supplied 
with device or float.

Vertical Submersible Sump

1

2

3

5

8

9

7

6

1.  GFCI OUTLET

6.    DISCHARGE PIPE

2.  CHECK VALVE

7.  SUMP PUMP

3.  VENT PIPE

8. SWITCH

4.  GASKET/BASIN LID
5     PIPE INLET

9. BASIN
10.  POWER CORD

MINIMUM 

BASIN 

HEIGHT

22 IN.

11 IN. DIAMETER MIN.

4

10

ON LEVEL 
APPROX. 9 IN.
OFF LEVEL
APPROX. 4 IN.

Содержание CDU800SS

Страница 1: ...by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Operating Instructions and Parts Manual Sumps Images are for illustration purposes only Not all models are shown CONSTRUCTION MOTOR HOUSING Stainless Steel CDU1000 CDU980E CDU800SS CDU790SS Coated Steel CDU800 CDU790 SPF33 SPF50 CDT...

Страница 2: ...res NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE de la prise ou contourner les fils de mise à la terre MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER rated to handle the current amps noted on the pump nameplate or cord tag S ASSURER QUE L ALIMENTATION ÉLECTRIQUE EST MUNIE D UN FUSIBLE OU D UN DISJONCTEUR d une valeur nominale appropriée pour supporter l intensité du courant ampérag...

Страница 3: ...magés ou si le raccordement tombe dans le puisard Si la prise n est pas à portée du cordon d alimentation de la pompe contacter un électricien qualifié pour installer une nouvelle prise CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY MISE EN GARDE LA MENTION MISE EN GARDE INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI SI ELLE N ...

Страница 4: ...ertical n est pas remplaçable This product can expose you to chemicals including DEHP which is known to the State of California to cause cancer birth defects and reproductive harm For more information go to www P65Warnings ca gov Ce produit peut vous exposer à des produits chimiques notamment du DOP reconnus par l État de Californie comme étant cancérigènes et à l origine d anomalies congénitales ...

Страница 5: ...ioned in a downward slope away from the foundation so any remaining water will drain away and not freeze 15 Secure the basin cover and gasket to the basin to prevent debris from falling into the basin prevent personal injury and to contain gases and or odors TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and ordina...

Страница 6: ...inadequate wiring incorrect motor conditions or at the end of product life TROUBLESHOOTING CHART Symptoms Possible Cause s Suggested Remedies Pump will not start or run 1 Water level too low 2 Blown fuse or tripped circuit breaker 3 Low supply voltage 4 Motor 5 Switch 6 Inlet screen clogged 7 Switch obstruction 1 Water must be at the appropriate level to activate switch 2 If blown determine cause ...

Страница 7: ...Remove debris 3 Replace pump 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE SUMP MAINTENANCE The pump should be inspected 3 4 times per year for pump movement or buildup of debris on the switch or float Reposition pump if it has moved Remove any debris that could interfere with the ope...

Страница 8: ...INSTALLATION MANUAL AND REPLACEMENT PARTS 8 REPAIR KITS REF NO DESCRIPTION PART NUMBER 1 FLOAT KIT 60038 WYN1 2 TETHER SWITCH 56835 WYN1 2 1 ...

Страница 9: ... to operate in accordance with WAYNE s written instructions This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne Water Systems written instructions THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES OBLIGATIONS OR AGREEMENTS EXPRESSED OR IMPL...

Отзывы: