Operating Instructions and Parts Manual

Installation and Operation

(Continued

)

Do not handle pump with wet
hands or when standing in
water or on a damp surface when the
unit is operating or fails to operate.
Always disconnect pump power cord
from power source before handling.

6. Plug the power cord into a ground-

ed 115-volt AC power outlet.  The
pump will start operating as soon as
the power cord is plugged into the
power outlet.

7. The pump will remove water down

to 1/8 inches of the hard surface the
pump was placed on.

8. The pump should be turned off

once the water level reaches the
1/8-inch mark.

Do not allow 

pump to run dry.

The shaft seal depends on water for
lubrication.  Operating pump without
water will damage the shaft seal and
cause pump failure.

Maintenance

Always disconnect electric
supply before attempting to
install, service, relocate or per-
form any maintenance.  Failure to do so
could result in fatal electrical shock.

Minimal service is required for this
pump.  If pump should fail to operate,
perform the following troubleshooting
guidelines: 

1. The motor housing of the

pump is completely sealed
and requires no service.
Disassembly of the motor
housing or alteration of the power
cord could result in fatal electrical
shock.

2. Verify pump is operating correctly.

a. Disconnect pump from power

source.

b. Disconnect  discharge hose from

pump.

c. Immerse pump in a bucket or tub

of water.

d. Plug power cord into a grounded

115 volt AC power outlet.  If
pump operates correctly proceed
to step #3.  If pump does NOT

operate, unplug power cord and
proceed to maintenance guide-
line item 4 in this section.

3. Verify discharge hose is correctly

installed.

a. Connect hose to another water

source such as a faucet.  If water
flows through hose, proceed to
step 3b.  If water is restricted, ver-
ify discharge hose is unwound.
Remove all kinks, bends or
obstructions in hose.

b. Verify pumping height does NOT

exceed 25 feet (See Figure 1).  If
pumping height is greater than
25 feet, this pump will NOT work.

4. Periodic cleaning of pump is

required to maintain performance
of the pump.  Follow the cleaning
steps listed below: 

a. Unplug the power cord.

b. Remove the 3 screws at the bot-

tom of the pump.

c. Remove the volute cover.  Note

the alignment marks.

d. Remove the gasket.  Note how

the openings in the gasket align
with the openings in the pump
base.

e. Remove the debris and make sure

the impeller turns freely.

Figure 1 Water Level

25 Ft. Max.

Water Level

f. Replace the gasket making sure

the openings are aligned.

g. Replace the volute cover.

h. Replace the 3 screws.

Содержание 351301-001

Страница 1: ... septic tanks or under ground vaults to pump raw sewage or effluents Never use in hazardous or explosive locations 1 This pump has been designed to attach to a standard garden hose Thread the female end of the gar den hose to the male discharge on the pump 2 To reduce leakage between the pump and the hose place a hose washer not included on the gar den hose before installing to the pump 3 For best...

Страница 2: ...g or alteration of the power cord could result in fatal electrical shock 2 Verify pump is operating correctly a Disconnect pump from power source b Disconnect discharge hose from pump c Immerse pump in a bucket or tub of water d Plug power cord into a grounded 115 volt AC power outlet If pump operates correctly proceed to step 3 If pump does NOT operate unplug power cord and proceed to maintenance...

Страница 3: ...list Address parts correspondence to Wayne Water Systems 100 Production Drive Harrison OH 45030 U S A 1 Power cord 31006 002 31006 002 1 2 Discharge fitting 15875 15875 002 1 3 Outer housing with o ring 28053 001 28053 001 1 19023 001 19023 001 1 4 Impeller 23097 23097 1 5 Volute gasket 23122 23122 1 6 Volute cover with screen 28056 001 28056 002 1 Ref No Description TSC130 250 TSC160 Qty 1 2 3 4 ...

Страница 4: ...ES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breac...

Отзывы: