Wayne 321205-001 Скачать руководство пользователя страница 2

Models .PC1 .and .PC2 .include .a .6 .foot .
long .suction .hose, .a .water .suction .
attachment, .and .a .replacement .parts .kit .
which .includes: .impeller, .gasket, .shaft .
seal, .and .two .motor .brushes . .Models .
PC1 .and .PC2 .can .be .used .without .the .
water .suction .attachment .

  Always disconnect  power source 
before attempting to install, service, 
or maintain the pump. Never handle a 
pump with wet hands or when standing 
on wet or damp surface or in water.  
Fatal electrical shock could occur.

1 . . . .A .ground .fault .circuit .interrupter .

(GFCI) .is .required .for .Model .PC2 .

  Risk of electrical shock!  This pump is 
supplied with a grounding conductor 
and grounding type attachment plug.  
A grounded receptacle in conformance 
with current NEC and local codes must 
be used (See Figure 1). Do not use 
model PC2, 115 V Transfer Pump in 
swimming pool areas. 

2 . . . .Model .PC1 .operates .on .12V .DC .only . . .

Model .PC2 .operates .on .115V .only . . .
Voltage .and .current .of .power .supply .
must .match .the .requirements .of .the .
pump . .Model .PC1 .has .color-coded .
battery .clamps .for .12V .operation . .
Model .PC1 .requires .14 .amps .at .12 .
VDC .

3 . . . .Never .use .an .extension .cord .to .

power .this .unit .

  Risk of fatal  electrical  shock. Never 
cut off the round grounding prong.  
Cutting the cord or plug will void 
the warranty and make the pump 
inoperable.

4 . . .Use .a .strainer .when .pumping .from .a .

creek, .pond, .or .source .where .foreign .
objects .may .be .sucked .into .the .
pump . . .The .strainer .should .prevent .
solids .from .entering .the .inlet .line .

5 . . A .regular .garden .hose .may .be .used . .

as .a .discharge .line .

6 . . The .inlet .or .suction .hose .should .

not .be .longer .than .15 .feet; .and .
the .vertical .distance .between .the .
pump .and .the .water .level .should .
not .be .any .higher .than .10 .feet . .The .
maximum .discharge .height .is .30 .
feet .

7 . . . At .times, .an .overload .due .to .

overheating, .low .voltage, .jammed . .
impeller, .etc . .may .shut .the .pump .off . . .
Unplug .or .turn .off .the .pump .and .
wait .at .least .ten .minutes . . .The .pump .
will .cool .and .automatically .reset . .
(Model .PC2 .only)

8 . . . Motor .should .never .be .operated .

for .more .than .2 .hours .continuously . . .
Critical .heating .can .occur .and .might .
severely .damage .the .pump .and .void .
warranty .

operation

1 . . Add .1 .tablespoon .of .vegetable .oil .

to .both .inlet .and .outlet .to .prime . . .
Attach .included .6 .foot .suction .hose .
to .inlet .of .pump . .Attach .garden .
hose .to .outlet .of .pump . . .There .
must .be .a .gasket .in .place .to .insure .
that .these .connections .are .airtight, .
otherwise .the .pump .will .not .prime . .

2 . . Connect .water .suction .attachment .

to .the .open .end .of .inlet .hose .and .
place .below .water .surface . . .(Water .
suction .attachment .is .optional .
for .both .PC1 .and .PC2 .models .) .
The .water .suction .attachment .is .
designed .to .fit .the .male .end .of .
a .garden .hose . . .Place .the .water .
suction .attachment .as .near .as .
possible .to .the .middle .of .the .water .
that .is .to .be .pumped . .

3 . . Examine .the .inlet .and .outlet .hoses .

to .insure .there .are .no .blockages, .
kinks .or .bends .

 . .

 .

 

Place switch in  

  “OFF” position 

before connecting or disconnecting 
battery terminal clamps.

2

Operating .Instructions .and .Parts .Manual

www.waynepumps.com

Installation

IMPorTanT BaTTery 
InforMaTIon

Be .certain .that .the .area .around .the .
batteries .is .well .ventilated . .Before .
servicing .the .batteries, .blow .away .
gasses .by .waving .a .piece .of .cardboard .
near .the .batteries .

 

Dangerous  

  hydrogen gas 

can be released from batteries while 
charging. Sparks can ignite the gas 
in an enclosed space. Wear safety 
goggles when connecting batteries. 
Battery connections should be made 
in a well-ventilated area.

 

Working in the  

  vicinity of lead 

acid batteries can be dangerous. 
Before making connections or 
servicing the batteries, read and 
follow instructions in all applicable 
instruction manuals. To reduce the 
risk of battery explosion, follow 
the instructions in this manual and 
those published by the battery 
manufacturer, as well as those of 
any other equipment used in the 
surrounding area.

An .assistant .should .be .present .or .
close .enough .to .come .to .your .aid .in .
the .event .of .an .emergency . .Have .a .
reliable .source .of .fresh .water .and .
soap .nearby .in .case .battery .acid .
contacts .clothing, .skin .or .eyes .
Wear .eye .and .clothing .protection .
when .working .around .lead .acid .
batteries . .
Avoid .touching .your .eyes .when .
working .around .lead .acid .batteries .

 

If battery acid  

  contacts your 

eye(s), flush with cold running 
water for 20 minutes and seek 
immediate medical attention. If acid 
contacts your skin or clothing, wash 
immediately with soap and water. 

 

Never smoke or  

  allow a spark or 

flame in the vicinity of the battery.

  

Avoid dropping  

  metal tools on 

the battery posts because they may 
spark or short-circuit the system or 
battery, causing an explosion.

Содержание 321205-001

Страница 1: ...ls Avoid kinking the cord and replace damaged cords immediately This pump has been evaluated for use with water only Unpacking Inspect this unit before it is used Occasionally products are damaged dur...

Страница 2: ...luded 6 foot suction hose to inlet of pump Attach garden hose to outlet of pump There must be a gasket in place to insure that these connections are airtight otherwise the pump will not prime 2 Connec...

Страница 3: ...on motor shaft 4 Reassemble gasket cover plate and cover plate screws Shaft Seal Replacement Motor shafts are sealed with factory pre lubricated lip type seals which are good for the life of the pump...

Страница 4: ...r retain prime after operating 1 Air leak in suction line 1 Repair suction line by tightening inlet connection or replace 2 Impeller blocked 2 Remove blockage 3 Worn seal 3 Replace seal 4 Suction lift...

Страница 5: ...PC1 and PC2 Series Notes www waynepumps com...

Страница 6: ...ress any correspondence to Model number Wayne Water Systems Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Operating Instructions...

Страница 7: ...Seal 1 D Retaining Ring 1 E Brushes 2 2 Brush Kit 66063 WYN1 E Brushes 2 3 Water Suction Attachment 66064 WYN1 66064 WYN1 F Water Suction Attachment 1 G 6 ft Suction Hose 1 NOTE Replacement parts are...

Страница 8: ...PENS ES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the ab...