2. Setting

When the unit is ON, press [POWER] to enable Standby mode. Then the unit stops working 

and the standby indicator 

 turns on.

     

When the unit is OFF, press [POWER] to turn on the unit. Then the unit starts working and 

the standby indicator 

 turns off.

     

Power

Humidity Setting

When the unit is ON, press [Up] or [Down] to enter  the humidity setting. The humidity 
display      

 flashes and humidity "      " flashes to show the level. Press [Setting] again or 

    

wait for a while, to exit the setting.

When setting the humidity, press [Up] or [Down] to adjust the humidity level between 10-

90%RH (noncycle setting). Press [Up] once to increase 1%RH of the humidity level, while 

press [Down] once to decrease 1%RH of the humidity level. Hold the buttons to 

continuously increase/decrease the level. When setting finished, press the [Setting] once or 

wait for seconds to exit the humidity setting. 

Timer Setting

If setting up the timer in OFF mode, then it's the power-on delay. If setting up the timer in 

ON mode, then it’s power-off delay. But if the timing hour is 00h, the setting will be invalid.

When the dehumidifier is on, press [Timer] button to enter timing setting. The timer icon 

lights on, and the number "      " flashes and shows the remaining working hours. Press 

[Timer]   again or wait for seconds to exit the setting.  In the timer setting, press [Up] or 

[Down] to adjust the timing hours between 00-24 (noncycle setting). Press [Up] once to 

increase one hour while decrease one hour with button [Down]. Hold the buttons to 

continuously increase/decrease the hours. When setting finished, press [Setting] once or 

wait  for seconds to exit the timer setting.

Continuous Dehumidifying

Set up the humidity level at 10% RH, and the unit will enter continuous dehumidifying mode 

(the icon      lights). The dehumidifying is not affected by the humidity level has been set 

     

before.

OPERATION 
DESCRIPTIONS

MAX

Содержание DP900B

Страница 1: ...Commercial Dehumidi er Please read the manual carefully before using the unit DP900B USER MANUAL...

Страница 2: ...use of the dehumidifier Our dehumidifiers are widely used in family bedrooms bathrooms basements offices and storage rooms etc The dehumidifiers from provide quick and efficient operation to reduce Wa...

Страница 3: ...nternal damage it is very important to keep refrigeration units like this one upright throughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in B...

Страница 4: ...reference only Please check the corresponding content and operate the machine based on the actual product The right to interpret the relevant terms belongs to the company TABLE OF CONTENTS Safety Inst...

Страница 5: ...es or ammable liquid on this machine Do not put or place heavy objects on the machine or place children and pets on the unit Do not place this machine in a con ned space If the power cord is damaged p...

Страница 6: ...PARTS DESCRIPTION P 02 Continuous Drainage Port Control Panel...

Страница 7: ...tton Turn up the parameters including humidity level timing or cleaning hours Power Turn on or o the unit Setting Button Set up the humidity timing hours or cleaning mode etc Down Button Turn down the...

Страница 8: ...r seconds to exit the humidity setting Timer Setting If setting up the timer in OFF mode then it s the power on delay If setting up the timer in ON mode then it s power o delay But if the timing hour...

Страница 9: ...sing 1 day by pressing Down once Hold the buttons to continuous increase decrease the days When setting nished press button Setting once or wait for seconds to exit the setting Cleaning Setting Check...

Страница 10: ...he indicator Smart Dehumidifying turns o when turning o the unit The icon ashes when the fan starts working in time delay the icon lights on when the fan start working the icon turns o when the fan st...

Страница 11: ...sensor and connecting cable of the RHI 112A port Change the temperature sensor of PTI port Make sure the water tank is well placed and the WF port is properly connected Change the sensor and connectin...

Страница 12: ...unit for long time to prevent bacteria and mould breed 1 Remove the inlet panel and get the lter out 2 Clean the dust on the surface with the vacuum or ush and wash the lter with detergent and place...

Страница 13: ...in high temperature conditions icon lights up The unit shall not used in low temperature conditions The unit is place at uneven surface Place the unit at somewhere at and even The inlet or outlet may...

Страница 14: ...P 10...

Страница 15: ...L Day 790W 8 1A 1 2A RLA 9 4A LRA 47A R410a 650g 5 5MPa 800 PSIG 4 0MPa 580 PSIG 1 7MPa 247 PSIG P 11 SPECIFICATIONS Working temperature of this product ranges from 41 F 5 C to 100 F 38 C In any case...

Страница 16: ...applicable Warranty Extend Your Warranty by 1 Year Customer Support There are our general terms for the warranty service but we always encourage our customers to contact us if any issues regardless of...

Страница 17: ......

Страница 18: ...We are expecting to see our products fulfill your life and hear your voice Your satisfaction means a lot to us Please tag us if you share a snap on your social media...

Отзывы: