2. Humidity Setting
In power-on status, press "up"or "down" button once to set humidity value, "RH%" will light
up and the large figure will flash to display the humidity value.
In the humidity setting mode, you can set humidity value within the range of 10-98% RH.
Press "Timer/Function" button once or no operation after seconds, it will exit the humidity
setting mode automatically.
3. TIMER Setting
This TIMER Setting function is designed for you to set a time to turn on ( when the
machine is off) or turn off (when the machine is on) the machine automatically by the timer.
In power-on/off status, long press " TIMER " button to enter timer setting mode, "H" and
the "TIMER" icon will light up, and the small figure will flash to display the initial setting
time as "
".
00
In "TIMER" setting mode, you can press "Up" or "Down" button to adjust the setting time
within the range of 1-24 hours, which can be set again after invalid.
When no TIMER setting, the small figure will display the current temperature. If you
successfully set the "TIMER", the small figure will display the remaining setting time, and
if you press the "Timer/Function" then, you can check the current temperature again.
4. Action Description
Power on: Compressor 1 starts after the fan has worked for a few seconds; compressor 2
starts after compressor 1 has worked for another few seconds.
Power off: Compressor 1 and compressor 2 shuts down at once, and the fan will stop after
a few seconds.
The compressor features a "3 minutes delay protection function" , when the dehumidifier
is powered, the compressor can only start after 3 minutes after its last shutdown.
5. Status Description
When the machine is delayed, the "Running" character will flash, and if the fan is running,
the running symbol " "
will be on, otherwise it will be off.
When the compressor is running, the dehumidification symbol " "
will be on, otherwise
it will be off.
When the humidity has reached the setting value and dehumidification stops, the "Wet
Controller" character will flash, indicating the wet control status.