Waygate Technologies DM5E Basic Скачать руководство пользователя страница 4

User-friendly operator interface

All versions of the DM5E have the same user-friendly 

operator keypad interface. This has a central  
mode key, a calibration/on/off key, two function 
arrow keys to activate and set functional control 
and four arrow keys for adjusting parameter values 
and for navigating through the intuitive single-level 
menu. The keypad allows access to all calibration, 
set-up and measurement display modes of the 
instrument. With the DL version, a file display mode 
allows users to create and store thickness readings 
in files. All calibration is menu-driven and the 
operator is guided through every step. There is  
a built-in calibration reminder, which can be set to 
remind the user to calibrate after a specified number 
of measurements or after a given time period. 

New range of high-performance 

probes

A new set of ultrasonic probes has been developed 

for the DM5E family to provide the instruments with 
optimized performance, even at very high temp- 
eratures. The DA5xx series includes a 5-MHz 
standard probe for general purpose applications, a 

2-MHz version for high penetration and a 7.5-MHz 

fingertip probe. A newly developed 5-MHz 
high-temperature probe offers an operating range 
from -10°C up to +204°C. (Standard probes 
operate to 70°C.)

Содержание DM5E Basic

Страница 1: ...DM5E corrosion thickness gauges A range of high performance reliable and easy to use instruments...

Страница 2: ...er previous corrosion thickness gauges in terms of better thickness measurement stability and repeatability at normal and elevated temperatures It has been designed for operation in the harshest worki...

Страница 3: ...and nominal thickness Choose from three levels of functionality DM5E Basic DM5E or DM5E DL The DM5E The DM5E incorporates all the features of the DM5E Basic but also offers the DUAL MULTI operating m...

Страница 4: ...adings in files All calibration is menu driven and the operator is guided through every step There is a built in calibration reminder which can be set to remind the user to calibrate after a specified...

Страница 5: ...om the fact that the maximum thickness measured is displayed DIFF RR Compares the measured thickness with a user specified nominal thickness The dimensional difference between the two values is displa...

Страница 6: ...selectable 24 Hz scan mode capture rate Thickness value display NORMAL view mode 5 Digit 10 6 mm 0 4 high B SCAN view mode 5 Digit 2 55 mm 0 1 high Display of last reading Solid filled or hollow digit...

Страница 7: ...Model DA590 Model FH2E Frequency 5 MHz 2 MHz 7 5 MHz 5 MHz 7 5 MHz Probe style Standard Standard Fingertip High temperature Fingertip Operating temperature range continuous 20 to 70 C 20 to 70 C 20 to...

Страница 8: ...ce or obligation Contact your BHI representative for the most current information The Baker Hughes logo is a trade mark of Baker Hughes The BH Monogram is a trademark of Baker Hughes JB170718 04 2020...

Отзывы: