Display WAY-AX 

 
 

Installation Guide 

 
 

Product features: 

 

  Operating modes for visualization of input 1, input 2 or combinations of inputs (IN1+IN2, IN2-IN2, 

IN1xIN2, IN1:IN2) 

  Two universal 16 bit analog inputs for -10 … +10 V / 0 … 10 V / 0 … 20 mA / 4 … 20 mA 

  High accuracy reference output 10 V for potentiometers > 1 kOhm 

  Bright and high-contrast display with event-dependent color variations 

  Emulation of a 7-segment display inclusively icons and units 

  Intuitive and easy parameterization by plain text and touchscreen 

  24 V auxiliary output for encoder supply  

  Totalization for each input 

  Linearization with 24 control points for each input 

  Numerous features, e. g. tara, averaging filter, sampling time for each input

 

  3.78 x 1.89 inch norm panel housing and IP65 protection

 

 

Available Options: 

 

 

WAY-AX-S: 

Basic unit with 2 analog inputs (16 Bit), 3 control inputs

 

  Option 

AC:  

Power supply 115…230 VAC

 

  Option

 AO:  

16 bit analog output, 4 control outputs, serial RS232 interface 

 

  Option

 CO:  

4 control outputs, serial RS232 interface

 

  Option

 RL:  

2

 

relay outputs

 

   

 

All options can be combined  

 

 

 

 

Legal notices:

 

All contents included in this manual are protected by the terms of use and copyrights of WayCon GmbH. Any 
reproduction, modification, usage or publication in other electronic and printed media as well as in the 
internet requires prior written authorization by WayCon GmbH. 

 

 

Содержание WAY-AX

Страница 1: ...Linearization with 24 control points for each input Numerous features e g tara averaging filter sampling time for each input 3 78 x 1 89 inch norm panel housing and IP65 protection Available Options...

Страница 2: ...10 3 10 Relay Output Option RL 10 4 Display and touch screen 11 4 1 Screen structure for parametrization 11 4 2 Screen structure in operation 12 5 Parameter Overview Menu Structure 14 5 1 General Menu...

Страница 3: ...t to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual The rais...

Страница 4: ...st be ensured Indications about the permissible wire cross sections for wiring are described in the Technical Specifications Before first start up it must be ensured that all connections and wires are...

Страница 5: ...ameter menu The device can be set to one of the following operation modes SINGLE single channel operation of input 1 DUAL two channel operation of input 1 and 2 IN 1 IN 2 two channel operation of inpu...

Страница 6: ...liary voltage output All GND terminals are internally interconnected 3 2 Auxiliary Voltage Output Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders The output voltage dep...

Страница 7: ...t input can be set in the Menu IN 1 IN 2 PROPERTIES Important Before connecting the sensor the configuration voltage or current input must be set Wiring of the intrecmental inputs Voltage input Curren...

Страница 8: ...exceptionally mechanical contacts are used please connect an external capacitor between GND and the corresponding input A capacity of 10 F will reduce the input frequency to 20 Hz and miscounting due...

Страница 9: ...rd Sub D 9 connector 3 8 Control Output Option AO CO Four control outputs are available at terminal 20 21 22 and 23 Switching conditions can be set in the PRESELECTION MENU The output Ctrl Out1 4 are...

Страница 10: ...ltage output and is about 3 VA 3 10 Relay Output Option RL Two relay outputs with potential free changeover contacts are available at terminal 27 28 29 and 30 31 32 Switching conditions can be set in...

Страница 11: ...rameter menu via arrow buttons and confirm with OK The menu selection can be terminated with C Parameter selection Select the parameter via arrow buttons and confirm with OK The parameter selection ca...

Страница 12: ...play are defined in the DISPLAY MENU Single channel display with unit and status bar To switch to the next display press the touch screen Control or Relay status are only shown with Option AO CO RL Tw...

Страница 13: ...Seite 13 48 Display with actual minimum maximum values of input 1 and input 2 To switch to the next display type on the touch screen...

Страница 14: ...ALUE END VALUE DECIMAL POINT SCALE UNITS SAMPLING TIME AVERAGE FILTER OFFSET LINEARIZATION TOTALIZATION IN 1 LINEARIZATION P1 X P1 Y P2 X P2 Y P23 X P23 Y P24 X P24 Y IN 1 TOTALIZATION TIME BASE DIVID...

Страница 15: ...CK 3 START UP DELAY 3 EVENT COLOR 3 PRESELECTION 4 MENU SOURCE 4 MODE 4 HYSTERESIS 4 PULSE TIME 4 OUTPUT TARGET 4 OUTPUT POLARITY 4 OUTPUT LOCK 4 START UP DELAY 4 EVENT COLOR 4 Menu Parameter SERIAL M...

Страница 16: ...IN code to lock the quick start of the menu PRESELECTION VALUE for entering the preselection values master PIN 6079 This Lock function is only useful in conjunction with active lock function in PIN PA...

Страница 17: ...nes the dispay value of an input signal 10V bzw 20mA Signal values between START VALUE and END VALUE behave proportinal 64999 Smallest end value 10000 Default value 64999 Highest end value DECIMAL POI...

Страница 18: ...t affect the calculation of the display value The number of decimal places must be defined with the parameter DECIMAL POINT 0 V Default 1 mV 2 A 3 mA 4 km h 5 mph 6 feet min 7 inch min 8 g 9 kg 10 oz...

Страница 19: ...rage cycles 3 8 numbers of floating average cycles 4 16 numbers of floating average cycles OFFSET This parameter defines the zero offset tara of the input 64 999 Smallest offset 0 Default value 64 999...

Страница 20: ...inate of the linearization point This value representing the display value which the unit show in the display without linearization 99999999 Smallest X coordinate 0 Default value 99999999 Largest X co...

Страница 21: ...ery minute 2 HOURS The current value is added to INPUT 1 TOTAL every hour 3 COMMAND The current value is added to INPUT 1 TOTAL when using the command ADD TO TOTAL 1 for the operation function at the...

Страница 22: ...ot affect the calculation of the display value The number of decimal places must be defined with the parameter DECIMAL POINT 0 V Default 1 mV 2 A 3 mA 4 km h 5 mph 6 feet min 7 inch min 8 g 9 kg 10 oz...

Страница 23: ...ut 2 at 10 V or 20 mA see IN 1 Properties DECIMAL POINT Position of the decimal point see IN 1 Properties SCALE UNITS The displayed units see IN 1 Properties SAMPLING TIME S Sampling interval see IN 1...

Страница 24: ...coordinate of the linearization point see IN 1Linearization 5 7 IN 2 Totalization The totalization function is defined in this menu TIME BASE The time base of the totalization see IN 1 Totalization DI...

Страница 25: ...fines the divider the result of the link will be charged 99999999 Smallest end value 1 Default value 99999999 Highest end value ADDITIVE VALUE This parameter defines the additive constant the result o...

Страница 26: ...does not affect the calculation of the display value The number of decimal places must be defined with the parameter DECIMAL POINT 0 V Default 1 mV 2 A 3 mA 4 km h 5 mph 6 feet min 7 inch min 8 g 9 kg...

Страница 27: ...RL PRESELECTION 1 Preselection switching point 1 99999999 Smallest value 1000 Default value 99999999 Highest value PRESELECTION 2 Preselection switching point 2 99999999 Smallest value 2000 Default v...

Страница 28: ...1 the reference source is input 1 1 INPUT 2 the reference source is input 2 2 LINKAGE 1 2 the reference source is the result of the linking of input1 and input 2 3 INPUT 1 TOTAL the reference source i...

Страница 29: ...the following switching condition is applied Display value PRESELECTION 1 HYSTERESIS 1 OFF Display value PRESELECTION 1 HYSTERESIS 1 OFF 3 RESULT PRES Display value is greater or equal PRESELECTION 1...

Страница 30: ...tput is set when at least one switching condition is true 0 NO No assignment 1 CTRL OUT 1 Switching condition assigned to Ctrl Out 1 2 CTRL OUT 2 Switching condition assigned to Ctrl Out 2 3 CTRL OUT...

Страница 31: ...automatic start up suppression 0 000 No start up suppression 60 000 Start up suppression in seconds EVENT COLOR 1 Event depending change of the display color for the switching condition of preselectio...

Страница 32: ...ndition of preselection 2 See chapter PRESELECTION 1 MENU OUTPUT TARGET 2 Assignment of an output or relay for the switching condition of preselection 2 See chapter PRESELECTION 1 MENU expect default...

Страница 33: ...signment of an output or relay for the switching condition of preselection 3 See chapter PRESELECTION 1 MENU see PRESELECTION 1 MENU 3 CTRL OUT 3 Assignment of switching conditions at Ctrl Out 3 OUTPU...

Страница 34: ...OUTPUT TARGET 4 Assignment of an output or relay for the switching condition of preselection 4 See chapter PRESELECTION 1 MENU except default value see PRESELECTION 1 MENU 4 CTRL OUT 4 Assignment of...

Страница 35: ...mat 0 7 EVEN 1 7 data Parity even 1 Stop 1 7 EVEN 2 7 data Parity even 2 Stops 2 7 ODD 1 7 data Parity odd 1 Stop 3 7 ODD 2 7 data Parity odd 2 Stops 4 7 NONE 1 7 data no Parity 1 Stop 5 7 NONE 2 7 da...

Страница 36: ...onds for cycling transmission of SERIAL VALUE when using the serial output On a serial request the cycling transmission is stopped for 20 s 0 000 All cyclic transmission is switched off The unit will...

Страница 37: ...n the operation mode See chart in chapter IN 1 Totalization ANALOG FORMAT This parameter defines the output characteristics The analogue output is proportional to the display value With setting ANALOG...

Страница 38: ...the ANALOG END value is reached e g 95 00 corresponds to a conversion of 9 5 V or 18 mA when the ANALOG END value is reached 0 00 Smallest gain 100 00 Default value 110 00 Highest gain ANALOG OFFSET T...

Страница 39: ...Screen structure in operation d 12 RESET MIN MAX Reset the Min Max values d s 13 CLEAR LOOP TIME N A 14 ACTIVATE N A 15 STORE DATA N A 16 TESTPROGRAM N A 17 SET RED COLOR Red display Event depending c...

Страница 40: ...at falling edge dynamic INPUT 2 ACTION This parameter defines the function of the input Ctrl In 2 See parameter INPUT 1 ACTION INPUT 2 CONFIG This parameter defines the switching characteristics of th...

Страница 41: ...ion SOURCE DUAL TOP 0 INPUT 1 the reference source is input 1 1 INPUT 2 the reference source is input 2 2 LINKAGE 1 2 the reference source is the result of the linking of input1 and input 2 3 INPUT 1...

Страница 42: ...ightness 80 Default value 100 Max brightness CONTRAST This parameter defines the viewing angle 0 Viewing angle from top 1 Viewing angle from center 2 Viewing angle from bottom SCREEN SAVER S This para...

Страница 43: ...te AD2 unit address Low Byte C1 register code High Byte C2 register code Low Byte ENQ control character Hex 05 The following example shows the request string for readout of the actual input frequency...

Страница 44: ...parameters P1 X to P24 X are used to specify the coordinates on the x axis These are the measuring values that the unit normally would generate according to the actual input signal Now enter the atta...

Страница 45: ...10_x P15_x P16_x Pressure Sensor 0 20 mA P01_x P10_x P16_x P01_y P07_y P15_y P16_y Pressure Volume P15_x P10_y To solve the problem we divide the non linear part of the tank into 14 parts We enter the...

Страница 46: ...Seite 46 48 6 3 Dimensions Dimension in mm inch...

Страница 47: ...Seite 47 48 6 4 Technical specifications 7 8...

Страница 48: ...ion Voltage output Current output Resolution Accuracy current or voltage operation 10 10 V max 2 mA 0 4 20 mA burden max 270 Ohm 16 Bit 0 1 Control outputs Option CO Number of outputs Format level Out...