ELECTRICAL CONNECTION
Pin
UFA2 and UFA-6000
UFA-150-CP
Connection cable
K4P
Analog output
Switching output
Analog output
Switching output
1
+V
+V
+V
+V
BN
2
Analog output
Teach
Teach
Teach
WH
3
GND
GND
GND
GND
BU
4
Teach
Switching output
Analog output
Switching output
BK
1
2
3
4
connector M12
(male)
+
S
T
–
Pin 1
Pin 2
Pin 3
Pin 4
circuit diagram UFA2/UFA-6000
analog output
Pin 1
Pin 2
Pin 3
Pin 4
+
S
T
–
+
T
–
+
teach
npn
pnp
circuit diagram UFA2/UFA-6000
switching output
TEACHING FUNCTION UFA2 AND UFA-6000 ANALOG OUTPUT
Teaching the measurement range:
The measuring range is defined by two teach points. The output signal is scaled to the taught
measuring range.
Procedure:
1. Place the target on the position of the 1st teach point (i.e. where 0 V or 4 mA should be output).
2. Connect the teaching line (Pin 4) with +V (Pin 1) for 0.1...2 s. LED flashes slowly (1 Hz).
3. Within <20 s, place the target on the position for the 2nd teach point (i.e. where 10 V or 20 mA
should be output) and connect the teaching line with +V for 0.1...2 s.
4. LED flashes 2 times:
teach procedure successful
LED flashes 4 times:
teach procedure not successful
Changing the analog output signal:
The physical quantity (current/voltage) of the analog output is changed.
Procedure:
1. Connect the teaching line (Pin 4) with +V (Pin 1) for >6 s.
2. LED flashes 2 times:
change successful
LED flashes 4 times:
change not successful