ELECTRICAL CONNECTION

LX-PA general information

Power supply: max. 25 V

Output signal: 0...1 kΩ

Inverted signal: reverse Pin 1 and Pin 3

It is generally recommended that shielded, twisted pair cabling be used between transducer and 

electrical interface. The shield should remain open at the transducer and be tied to ground at the 

electrical interface.

Units with ranges 120 mm and less employ a single turn potentiometer which has no stops. On these 

units the wire rope will extend to a total length of approximately 200 to 250 mm. When extension 

beyond the specified measurement range occurs, the cursor of the potentiometer traverses a 

deadband after which the electrical output begins again.

LX-PA with solder terminals

LX-PA with cable output

1

2

3

ranges ≤120 mm

1

2

3

ranges ≥250 mm

+V (RD)

Cursor (WH)

GND (BK)

Shield

Note:

 cable shield is open at sensor.

Pin 1 / CCW: V+

Pin 2 / S, UX: Cursor

Pin 3 / CW: V-, GND

LX-EP2

Power supply: 5 VDC ±0.25 VDC

Excitation current: max. 30 mA

A

B

+V

5.4 kΩ ±25 %

signal

GND

B GND A +V

Connection cable 10517-xM

Function

Cable colour

B

GN

GND

BK

A

WH

+V

RD

GN

BK

WH

RD