ELECTRICAL CONNECTION
LX-PA general information
Power supply: max. 25 V
Output signal: 0...1 kΩ
Inverted signal: reverse Pin 1 and Pin 3
It is generally recommended that shielded, twisted pair cabling be used between transducer and
electrical interface. The shield should remain open at the transducer and be tied to ground at the
electrical interface.
Units with ranges 120 mm and less employ a single turn potentiometer which has no stops. On these
units the wire rope will extend to a total length of approximately 200 to 250 mm. When extension
beyond the specified measurement range occurs, the cursor of the potentiometer traverses a
deadband after which the electrical output begins again.
LX-PA with solder terminals
LX-PA with cable output
1
2
3
ranges ≤120 mm
1
2
3
ranges ≥250 mm
+V (RD)
Cursor (WH)
GND (BK)
Shield
Note:
cable shield is open at sensor.
Pin 1 / CCW: V+
Pin 2 / S, UX: Cursor
Pin 3 / CW: V-, GND
LX-EP2
Power supply: 5 VDC ±0.25 VDC
Excitation current: max. 30 mA
A
B
+V
5.4 kΩ ±25 %
signal
GND
B GND A +V
Connection cable 10517-xM
Function
Cable colour
B
GN
GND
BK
A
WH
+V
RD
GN
BK
WH
RD